Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Moses Technology vs Vapor Tunnel in Low Power Laser Lithotripsy (MT VT)

10 novembre 2026 aggiornato da: Polyvios Arseniou, National and Kapodistrian University of Athens

Double Blind Randomized Controlled Trial Comparing Two Distinct Pulse Modulation Modes in Low Power Laser Lithotripsy

The goal of this clinical study is to compare two different laser settings used to break up kidney and ureter stones during surgery. The study will include adults with kidney or ureter stones who are scheduled to undergo a procedure in which an endoscope is passed through the urinary tract and a laser is used to break the stones into smaller pieces.

The main question is whether one laser setting can break up stones using less energy than the other, while maintaining similar treatment effectiveness and safety.

A total of 110 participants will be randomly assigned to one of two groups:

  • One group will undergo stone treatment using Moses Technology.
  • The other group will undergo stone treatment using Vapor Tunnel.

Both methods use a laser to break stones into smaller pieces. The study will compare the amount of laser energy used in relation to the size of the stone. Researchers will also assess the duration of the procedure, how completely the stones are cleared, the movement of stones during surgery, and any complications.

The findings may help urologists understand which laser setting is more efficient and whether it offers advantages during the treatment of kidney and ureter stones.

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Stimato)

110

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

    • Attica
      • Marousi, Attica, Grecia, 15126
        • 2nd Department of Urology, Sismanogleio General Hospital

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • kidney/ureter stone
  • maximum stone diameter 5-20 mm (CT)
  • any stone composition
  • recent CT (3 months prior to procedure)
  • indication/no contraindications for laser lithotripsy
  • negative urine culture/adequate antibiotic preparation
  • informed consent

Exclusion Criteria:

  • pregnancy
  • inability/unwillingness to provide informed consent
  • radiolucent stones
  • ipsilateral urinary tract anatomical abnormalities
  • previous non-endoscopic surgery on the urinary tract
  • active urinary tract infection
  • acute kidney injury
  • bleeding disorders
  • inability to discontinue antithrombotic medication when required for the procedure

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Triplicare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Comparatore attivo: Moses Technology

Laser lithotripsy using Moses Technology pulse modulation by Lumenis Pulse 120H Ho:YAG laser system, that produces a two-part laser pulse. The first low-energy part produces a vapor cavity through which the second high-energy part is transmitted to the stone without energy loss, increasing laser efficacy.

Altri nomi:
  • Ho:YAG Laser Lithotripsy
Comparatore attivo: Vapor Tunnel

Laser lithotripsy using Vapor Tunnel pulse modulation by Quanta Cyber Ho Ho:YAG laser system, which creates one low-power long-length laser pulse that prevents stone retropulsion.

Altri nomi:
  • Ho:YAG Laser Lithotripsy

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Laser efficacy
Lasso di tempo: During ureteroscopic procedure

Total energy delivered by the Ho:YAG laser during stone lithotripsy, divided by the preoperative stone volume measured on computed tomography (CT). The result will be expressed in joules per cubic millimeter (J/mm³).

During ureteroscopic procedure

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Laser-on time
Lasso di tempo: During ureteroscopic procedure

The cumulative duration of laser activation during stone lithotripsy, measured in minutes and recorded by the laser system.

During ureteroscopic procedure
Operative time
Lasso di tempo: During ureteroscopic procedure

The total duration of the ureteroscopic procedure, measured in minutes from the beginning to the completion of the surgical procedure.

During ureteroscopic procedure
Total energy
Lasso di tempo: During ureteroscopic procedure

The cumulative energy delivered by the Ho:YAG laser during stone lithotripsy, measured in joules (J) and recorded by the laser system.

During ureteroscopic procedure
Lithotripsy rate
Lasso di tempo: During ureteroscopic procedure

Lithotripsy rate calculated as the preoperative stone volume, measured on CT in cubic millimeters, divided by the total laser activation time in seconds. Results will be expressed in mm³/s.

During ureteroscopic procedure
Stone-free rate
Lasso di tempo: One month after ureteral stent removal (ureteral stent removal typically removed 7-10 days after discharge)

The proportion of patients with no residual stone fragments larger than 3 mm on postoperative computed tomography (CT).

One month after ureteral stent removal (ureteral stent removal typically removed 7-10 days after discharge)

Altre misure di risultato

Misura del risultato
Misura Descrizione
Lasso di tempo
Intraoperative complications
Lasso di tempo: During ureteroscopic procedure

The proportion of patients experiencing one or more complications during the ureteroscopic procedure, including their type and nature.

During ureteroscopic procedure
Postoperative complications
Lasso di tempo: Within 30 days after the ureteroscopic procedure

The proportion of patients experiencing postoperative complications, including their type and severity, classified according to the Clavien-Dindo classification system.

Within 30 days after the ureteroscopic procedure
Length of hospital stay
Lasso di tempo: From hospital admission until discharge

The duration of hospitalization, calculated as the number of days from hospital admission to hospital discharge.

From hospital admission until discharge
Stone retropulsion
Lasso di tempo: During ureteroscopic procedure

Surgeon-assessed stone retropulsion during laser lithotripsy, evaluated according to the distance of stone displacement, frequency of retropulsion events, and impact of retropulsion on the completion of stone fragmentation.

During ureteroscopic procedure

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Pubblicazioni generali

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 novembre 2026

Completamento primario (Stimato)

1 novembre 2027

Completamento dello studio (Stimato)

1 ottobre 2029

Date di iscrizione allo studio

Primo inviato

3 novembre 2026

Primo inviato che soddisfa i criteri di controllo qualità

10 novembre 2026

Primo Inserito (Effettivo)

16 novembre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

16 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

10 novembre 2026

Ultimo verificato

1 novembre 2026

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi