Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Multicenter Clinical Validation of OSIS for Automated Ovarian Follicle Monitoring (MULTI-OSIS)

24 novembre 2026 aggiornato da: Fertoolity S.L.

Multicenter Clinical Validation of OSIS: A 3D Ultrasound-Based AI Tool for Automated Ovarian Follicle Monitoring in Diverse Clinical Settings

Monitoring ovarian follicles is an important part of fertility treatments, as it helps healthcare professionals assess how the ovaries respond to stimulation. Traditionally, follicles are measured manually using two-dimensional (2D) ultrasound, a process that can be time-consuming and may vary between operators.

This study aims to evaluate the accuracy of OSIS (Online System for Image Segmentation), an artificial intelligence (AI)-based software that automatically identifies and measures ovarian follicles using three-dimensional (3D) ultrasound images.

Women undergoing controlled ovarian stimulation for in vitro fertilization (IVF), egg donation, or fertility preservation will participate in the study at fertility clinics in the United States and Europe. During their ovarian stimulation monitoring visits, conventional manual 2D ultrasound measurements will be compared with automated measurements obtained using OSIS.

The study will also assess the consistency of measurements across different healthcare professionals, clinical settings, and ultrasound equipment, as well as the time required for each measurement method.

Panoramica dello studio

Descrizione dettagliata

This prospective, multicenter, observational, comparative clinical study aims to validate the accuracy, reproducibility, and generalizability of OSIS (Online System for Image Segmentation), an artificial intelligence (AI)-based medical device software developed by Fertoolity S.L. to automatically identify, segment, and measure ovarian follicles from three-dimensional (3D) transvaginal ultrasound images.

The study will be conducted across multiple fertility clinics in the United States and Europe, involving women undergoing controlled ovarian stimulation (COS) for in vitro fertilization (IVF), oocyte donation, or fertility preservation.

During routine ovarian stimulation monitoring visits, conventional two-dimensional (2D) ultrasound measurements will be performed manually by healthcare professionals, followed by the acquisition of 3D ovarian ultrasound volumes. These 3D images will be uploaded to the cloud-based OSIS platform for automated follicle segmentation and measurement.

The study will include repeated ultrasound measurements to assess intra-observer variability (consistency of measurements performed by the same operator) and, where applicable, inter-observer variability (consistency between different operators). Depending on the participating center and applicable local requirements, measurements may be performed by physicians, nurses, or ultrasound technicians/sonographers. All collected datasets will be reviewed and validated by the attending physician.

The primary objective is to evaluate the agreement between automated OSIS measurements and conventional manual 2D ultrasound measurements at the individual follicle level.

Secondary objectives include evaluating intra- and inter-observer measurement variability, comparing the time required for manual 2D measurements and the OSIS-based 3D workflow, and assessing agreement in antral follicle counts (AFC) between both methods and their correlation with anti-Müllerian hormone (AMH) levels.

The study will also evaluate the ability of each follicle measurement method to predict the number of mature oocytes (MII) retrieved, based on measurements obtained at the final monitoring visit before ovulation triggering.

Additional analyses will assess the consistency of OSIS performance across different geographical regions, clinical centers, professional profiles, and ultrasound equipment manufacturers, as well as user experience and the learning curve associated with the software.

OSIS is a CE-marked medical device in Europe but has not received U.S. Food and Drug Administration (FDA) clearance. This study is intended to generate clinical evidence regarding the accuracy, reliability, and reproducibility of OSIS in diverse clinical settings and may support future regulatory submissions in the United States.

Tipo di studio

Osservativo

Iscrizione (Stimato)

66

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 45 anni (Adulto)

Accetta volontari sani

Sì

Sessi ammissibili allo studio

Femmina

Metodo di campionamento

Campione di probabilità

Popolazione di studio

Women aged 18-45 undergoing controlled ovarian stimulation (COS) for in vitro fertilization (IVF), oocyte donation, or fertility preservation at participating fertility clinics in the United States and Europe.

Eligible participants will be recruited consecutively from women receiving COS at these centers. The study population may include women with infertility as well as healthy oocyte donors.

All participants must meet the protocol-defined inclusion and exclusion criteria and provide written informed consent before undergoing study procedures.

Descrizione

Inclusion Criteria:

  • Female patients aged 18-45 undergoing COS.
  • Expected to have ≥5 measurable follicles per ovary
  • Signed informed consent

Exclusion Criteria:

  • Participation in other clinical trials likely to interfere with this study
  • Known ovarian pathology or technical limitations for 3D ultrasound acquisition
  • BMI >35 kg/m² (technical limitation for adequate image quality)
  • Previous ovarian surgery affecting follicle assessment

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Modelli osservazionali: COHORT
  • Prospettive temporali: PROSPECTIVE

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
Women Undergoing Controlled Ovarian Stimulation (COS)

This cohort includes women undergoing controlled ovarian stimulation (COS) for in vitro fertilization (IVF), oocyte donation, or fertility preservation.

All participants will undergo conventional manual 2D ultrasound follicle measurements and 3D transvaginal ultrasound acquisitions during their ovarian stimulation monitoring visits, according to the study protocol.

The acquired 3D ultrasound volumes will be processed using OSIS Ovary, an AI-based, CE-marked medical device software for automated ovarian follicle segmentation and measurement.

Repeated measurements will be performed to assess intra-observer variability and, where applicable, inter-observer variability. Automated OSIS measurements will be compared with conventional manual 2D ultrasound measurements.

All participants will be included in a single observational cohort, without allocation to different ovarian stimulation treatments.

OSIS Ovary (Online System for Image Segmentation) is AI-based medical device software developed by Fertoolity S.L. that automatically segments and measures ovarian follicles in 3D transvaginal ultrasound images. During controlled ovarian stimulation (COS) monitoring, 3D ovarian volumes will be acquired and processed on the cloud-based OSIS platform to obtain follicle counts, mean diameters, and volumes. OSIS measurements will be compared with conventional manual 2D ultrasound measurements at the individual follicle level to assess agreement and reproducibility. Repeated 2D measurements and 3D acquisitions will assess intra-observer and, where applicable, inter-observer variability. The attending physician will review and validate the datasets. Study procedures will not interfere with clinical management.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Agreement Between OSIS and Manual 2D Follicle Diameter Measurements (ICC)
Lasso di tempo: At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).

Agreement between paired OSIS-derived 3D and manual 2D mean follicle diameter measurements will be assessed at the individual follicle level using the intraclass correlation coefficient (ICC, unitless). The analysis will account for repeated follicle measurements within participants and variation between centers.

At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Intra-observer Reproducibility of OSIS Follicle Diameter Measurements (ICC)
Lasso di tempo: At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).

Reproducibility of OSIS-derived mean follicle diameter from repeated 3D ultrasound acquisitions performed by the same operator will be measured using the intraclass correlation coefficient (ICC, unitless).

At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).
Inter-observer Reproducibility of OSIS Follicle Diameter Measurements (ICC)
Lasso di tempo: At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).

Agreement between OSIS-derived mean follicle diameter measurements obtained from 3D volumes acquired by different operators will be assessed using the intraclass correlation coefficient (ICC, unitless). This analysis will be limited to participating centers in the United States, Spain and Portugal.

At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).
Difference in Time Between Manual 2D and OSIS-Based 3D Follicle Assessment (Minutes)
Lasso di tempo: At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).

The time required to complete manual 2D measurements of both ovaries will be compared with the sum of 3D ovarian volume acquisition time and OSIS automated processing time. The reported measure will be the paired time difference (manual 2D time minus 3D acquisition and OSIS processing time), in minutes.

At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).
Agreement Between Manual 2D and OSIS Automated Antral Follicle Counts (ICC)
Lasso di tempo: At the baseline ultrasound assessment, within the first 4 days after the onset of menstruation (one assessment per participant).

At baseline, the number of antral follicles measuring 2-10 mm identified by manual 2D ultrasound and by automated OSIS analysis of 3D ovarian volumes will be compared. Agreement will be reported as an intraclass correlation coefficient (ICC, unitless).

At the baseline ultrasound assessment, within the first 4 days after the onset of menstruation (one assessment per participant).
Mature Oocyte Yield Prediction Error Using OSIS and Manual 2D Ultrasound (MAE)
Lasso di tempo: At the final pre-trigger ultrasound visit and subsequent oocyte retrieval during the same stimulation cycle (approximately 2 weeks).

Follicle counts obtained at the final pre-trigger visit using OSIS and manual 2D ultrasound will be used in separate models to predict the number of mature oocytes (MII) retrieved. Prediction accuracy will be reported as mean absolute error (MAE), in number of MII oocytes, for each method.

At the final pre-trigger ultrasound visit and subsequent oocyte retrieval during the same stimulation cycle (approximately 2 weeks).
Follicle Diameter Agreement Across Geographic Regions and Operator Profiles (ICC)
Lasso di tempo: At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).

The intraclass correlation coefficient (ICC, unitless) for agreement between OSIS-derived 3D and manual 2D mean follicle diameter measurements will be estimated by geographic region (United States versus Europe) and operator profile (physicians, nurses or sonographers, where permitted).

At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).
Follicle Diameter Agreement Across Ultrasound Equipment Manufacturers (ICC)
Lasso di tempo: At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).

The intraclass correlation coefficient (ICC, unitless) for agreement between OSIS-derived 3D and manual 2D mean follicle diameter measurements will be estimated separately for each ultrasound equipment manufacturer to assess the consistency of software performance across equipment brands.

At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).
OSIS Ovary Ease-of-Use Score (7-Point Likert Scale)
Lasso di tempo: At completion of each operator's study assessments during the data collection period.

Healthcare professionals will rate the ease of use of OSIS Ovary on a 7-point Likert scale. The reported outcome is the ease-of-use score (points, 1-7). The association between this score and each user's number of previous OSIS cases will be examined as an indicator of the learning curve.

At completion of each operator's study assessments during the data collection period.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

1 gennaio 2027

Completamento primario (Stimato)

1 marzo 2027

Completamento dello studio (Stimato)

1 giugno 2027

Date di iscrizione allo studio

Primo inviato

14 novembre 2025

Primo inviato che soddisfa i criteri di controllo qualità

24 novembre 2026

Primo Inserito (Effettivo)

27 novembre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

27 novembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

24 novembre 2026

Ultimo verificato

1 novembre 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 2507-BCN-087-EL
  • Pro00091234 (Altro identificatore: Advarra IRB)

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Sì

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi