Effects of Inspiration Rise Time on Work of Breathing and Comfort of Conscious Patients on Mechanical Ventilation
Introduction Pressure Support Ventilation is widely used in patients in the ICU. Matching the patient's respiratory needs with adequate ventilator settings is necessary to ensure a low work of breathing (WOB) and maximal patient comfort. The inspiratory rise time (IRT) determines the time to reach the selected airway pressure. A short IRT results in a high peak inspiratory flow and a short time to reach that peak, but is also associated with the development of turbulent flow, resulting in increased WOB. Aim of this study is to investigate the effects of different IRT settings on WOB and patient comfort during pressure support ventilation.
Methods We will performed a prospective, single blind cohort study in patients on Pressure Support Ventilation. 10 healthy adult patients admitted to the ICU after elective facial or neck surgery will be included. All patients will be ventilated in pressure support mode using a Servo 300 ventilator (Siemens. Elema, Solna, Sweden), with a positive end expiratory pressure of 5 cm H2O, pressure support level of 12 cm H2O above PEEP and an inspiratory oxygen fraction of 0.40. Patients have to be awake and cooperative (Ramsay 2). WOB will be measured with an esophageal balloon, and miniature flowmeter (Bicore system). Breathing comfort will be evaluated using a visual analogue scale (VAS) ranging from 1 to 10. WOB and patient comfort will be measured (in random order) at 0, 5, and 10% IRT. For statistical analysis the two-way analysis of variance will used. A p value of < 0.05 will be considered statistically significant.
調査の概要
詳細な説明
Introduction Pressure Support Ventilation is widely used in patients in the ICU. Matching the patient's respiratory needs with adequate ventilator settings is necessary to ensure a low work of breathing (WOB) and maximal patient comfort. The inspiratory rise time (IRT) determines the time to reach the selected airway pressure. A short IRT results in a high peak inspiratory flow and a short time to reach that peak, but is also associated with the development of turbulent flow, resulting in increased WOB. Aim of this study is to investigate the effects of different IRT settings on WOB and patient comfort during pressure support ventilation.
Methods We will performed a prospective, single blind cohort study in patients on Pressure Support Ventilation. 10 healthy adult patients admitted to the ICU after elective facial or neck surgery will be included. All patients will be ventilated in pressure support mode using a Servo 300 ventilator (Siemens. Elema, Solna, Sweden), with a positive end expiratory pressure of 5 cm H2O, pressure support level of 12 cm H2O above PEEP and an inspiratory oxygen fraction of 0.40. Patients have to be awake and cooperative (Ramsay 2). WOB will be measured with an esophageal balloon, and miniature flowmeter (Bicore system). Breathing comfort will be evaluated using a visual analogue scale (VAS) ranging from 1 to 10. WOB and patient comfort will be measured (in random order) at 0, 5, and 10% IRT. For statistical analysis the two-way analysis of variance will used. A p value of < 0.05 will be considered statistically significant.
研究の種類
入学 (予想される)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Nijmegen、オランダ、6500 HB
- Radboud University Nijmegen Medical Centre
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- awake and cooperative patient
- ICU admission following surgery of head or neck
Exclusion Criteria:
- coagulopathy
- inability to sit
- hypoxemia and/or hypercapnia and /or hypocapnia
- Pain score > 5 (on scale 1-10)
- esophageal abnormalities
- Pregnancy
- COPD
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:独身
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
|---|
|
Work of breathing
|
二次結果の測定
結果測定 |
|---|
|
patient comfort
|
協力者と研究者
捜査官
- 主任研究者:Cornelia WE Hoedemaekers, MD PhD、Radboud University Medical Center
研究記録日
主要日程の研究
研究開始
一次修了
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- LBCH 0601
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。