- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT00294879
Effects of Inspiration Rise Time on Work of Breathing and Comfort of Conscious Patients on Mechanical Ventilation
Introduction Pressure Support Ventilation is widely used in patients in the ICU. Matching the patient's respiratory needs with adequate ventilator settings is necessary to ensure a low work of breathing (WOB) and maximal patient comfort. The inspiratory rise time (IRT) determines the time to reach the selected airway pressure. A short IRT results in a high peak inspiratory flow and a short time to reach that peak, but is also associated with the development of turbulent flow, resulting in increased WOB. Aim of this study is to investigate the effects of different IRT settings on WOB and patient comfort during pressure support ventilation.
Methods We will performed a prospective, single blind cohort study in patients on Pressure Support Ventilation. 10 healthy adult patients admitted to the ICU after elective facial or neck surgery will be included. All patients will be ventilated in pressure support mode using a Servo 300 ventilator (Siemens. Elema, Solna, Sweden), with a positive end expiratory pressure of 5 cm H2O, pressure support level of 12 cm H2O above PEEP and an inspiratory oxygen fraction of 0.40. Patients have to be awake and cooperative (Ramsay 2). WOB will be measured with an esophageal balloon, and miniature flowmeter (Bicore system). Breathing comfort will be evaluated using a visual analogue scale (VAS) ranging from 1 to 10. WOB and patient comfort will be measured (in random order) at 0, 5, and 10% IRT. For statistical analysis the two-way analysis of variance will used. A p value of < 0.05 will be considered statistically significant.
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
Introduction Pressure Support Ventilation is widely used in patients in the ICU. Matching the patient's respiratory needs with adequate ventilator settings is necessary to ensure a low work of breathing (WOB) and maximal patient comfort. The inspiratory rise time (IRT) determines the time to reach the selected airway pressure. A short IRT results in a high peak inspiratory flow and a short time to reach that peak, but is also associated with the development of turbulent flow, resulting in increased WOB. Aim of this study is to investigate the effects of different IRT settings on WOB and patient comfort during pressure support ventilation.
Methods We will performed a prospective, single blind cohort study in patients on Pressure Support Ventilation. 10 healthy adult patients admitted to the ICU after elective facial or neck surgery will be included. All patients will be ventilated in pressure support mode using a Servo 300 ventilator (Siemens. Elema, Solna, Sweden), with a positive end expiratory pressure of 5 cm H2O, pressure support level of 12 cm H2O above PEEP and an inspiratory oxygen fraction of 0.40. Patients have to be awake and cooperative (Ramsay 2). WOB will be measured with an esophageal balloon, and miniature flowmeter (Bicore system). Breathing comfort will be evaluated using a visual analogue scale (VAS) ranging from 1 to 10. WOB and patient comfort will be measured (in random order) at 0, 5, and 10% IRT. For statistical analysis the two-way analysis of variance will used. A p value of < 0.05 will be considered statistically significant.
Typ studiów
Zapisy (Oczekiwany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Nijmegen, Holandia, 6500 HB
- Radboud University Nijmegen Medical Centre
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- awake and cooperative patient
- ICU admission following surgery of head or neck
Exclusion Criteria:
- coagulopathy
- inability to sit
- hypoxemia and/or hypercapnia and /or hypocapnia
- Pain score > 5 (on scale 1-10)
- esophageal abnormalities
- Pregnancy
- COPD
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Przydział: Randomizowane
- Model interwencyjny: Zadanie krzyżowe
- Maskowanie: Pojedynczy
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
|---|
|
Work of breathing
|
Miary wyników drugorzędnych
Miara wyniku |
|---|
|
patient comfort
|
Współpracownicy i badacze
Śledczy
- Główny śledczy: Cornelia WE Hoedemaekers, MD PhD, Radboud University Medical Center
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Inne numery identyfikacyjne badania
- LBCH 0601
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .