The Effect of Neuraxial Analgesia on Maternal Breastfeeding
A previous randomized trial showed a possible negative association with labor neuraxial analgesia with high compared to low doses of fentanyl, and breastfeeding at 6 weeks postpartum. The significance of this study would be to validate or refute these findings. In addition, we hope to better evaluate the impact of cumulative dose of fentanyl on breastfeeding success in the initial postpartum period as well as at 6 weeks and 6 months post delivery. In order to better assess the quality of breastfeeding, we will utilize a validated breastfeeding assessment tool, LATCH (Latch, Audible swallowing, Type of Nipple, Comfort, and Help). This validated tool can assess maternal and infant variables, define areas of needed intervention, and determine priorities in providing patient teaching. The LATCH assessment has been shown to be a predictor of breastfeeding duration. We also plan to vary the dosage of fentanyl analgesia to determine the relationship between doses below 150 micrograms and changes in breastfeeding assessments. If a clear association between decreased breastfeeding and total fentanyl is identified, then regimens to reduce cumulative doses of fentanyl can be developed to improve the likelihood of breastfeeding success in mothers that desire to breastfeed.
Prior observational studies have inferred epidurals negatively affect breastfeeding by decreasing maternal plasma oxytocin release which may adversely affect infant neurobehavioral development. In a study by Beilin et al., it was reported that mothers receiving a high cumulative dose (> 150 microgram) epidural fentanyl were more likely to have stopped nursing 6 weeks postpartum compared with groups receiving no fentanyl or those receiving < 150 microgram. The study however, was underpowered to detect differences in breastfeeding prior to hospital discharge. In addition, the breastfeeding assessment tool utilized resulted in binary assessments, and therefore, a global rating of the quality of breastfeeding was not available.
調査の概要
詳細な説明
Participants in this study will be asked to complete a questionnaire called the Intrinsic Motivation Inventory (IMI).
Subjects will be randomized at the time they request neuraxial analgesia to one of three groups: Group 1: patient controlled epidural analgesia (PCEA) with bupivacaine 1mg/mL; Group 2: PCEA with fentanyl 1 mcg/mL plus bupivacaine 0.8 mg/mL; Group 3: PCEA with fentanyl 2 mcg/mL plus bupivacaine 0.625 mg/mL. Labor analgesia will be initiated in all groups using fentanyl 15 mcg plus bupivacaine 2.5 mg administered intrathecally. A basal infusion rate for the PCEA will be set at 8 mL/h with patient administered boluses of 8 mL every 10 minutes and a one hour limit of 32 mL. Breakthrough pain in all groups will be managed using anesthesiologist administered boluses of bupivacaine 1.25 mg/mL without fentanyl.
The patient as well as individuals who evaluate the study patient will be blinded to the group assignment. Samples of maternal venous blood ½ teaspoon (2 mls) and cord blood 2ml (1/2 teaspoon) will be collected after the delivery of the fetus. Blood concentrations of fentanyl and bupivacaine will be ascertained using high performance liquid chromatography (HPLC) analysis. Success of breastfeeding using the LATCH assessment tool will be measured by the lactation nurses within 24 hrs of delivery. At 6 weeks and at 3 months postpartum, follow-up phone calls by the anesthesia service will be made to assess for duration of breastfeeding. Also, the patient's obstetrician will be contacted to obtain the patient's Edinburgh Postnatal Depression Score to assess for postpartum depression, which may be a variable in decreasing breastfeeding success.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Illinois
-
Chicago、Illinois、アメリカ、60611
- Northwestern University
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Age 18 and above
- English speaking
- Term gestation (> 38 weeks)
- Parous parturients presenting for attempted vaginal delivery with a cervical dilation less than 8 cm
- They must request neuraxial labor analgesia
- Have previously successfully breastfed their child postpartum for at least 6 weeks
- Are expressing an interest in exclusively breastfeeding postpartum
Exclusion Criteria:
- Under 18 years of age
- Parturients who have received parental opioids during labor or have taken opioids prenatally
- Patients whose neuraxial analgesia failed due to abnormal spinal anatomy including scoliosis or previous spinal instrumentation
- Supplemental epidural opioids during labor
- Had an expedited labor with the delivery of the fetus less than 90 minutes from the placement of the neuraxial anesthestic
- Underwent cesarean delivery
- Received general analgesia for an unanticipated postpartum procedure
- Dropout criteria include patients who wished to be taken out of the study or were lost to follow-up
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Group 1
spinal fentanyl 15 micrograms plus bupivacaine 2.5 mg followed by a patient controlled epidural analgesia (PCEA) maintenance infusion of bupivacaine 1mg/mL
|
A basal infusion rate for the PCEA will be set at 8 mL/h with patient administered boluses of 8 mL every 10 minutes and a one hour limit of 32 mL.
Breakthrough pain in all groups will be managed using anesthesiologist administered boluses of bupivacaine 1.25 mg/mL without fentanyl.
他の名前:
|
|
実験的:Group 2
spinal fentanyl 15 micrograms plus bupivacaine 2.5 mg spinal followed by a PCEA infusion of fentanyl 1 micrograms/mL plus bupivacaine 0.8 mg/mL
|
A basal infusion rate for the PCEA will be set at 8 mL/h with patient administered boluses of 8 mL every 10 minutes and a one hour limit of 32 mL.
Breakthrough pain in all groups will be managed using anesthesiologist administered boluses of bupivacaine 1.25 mg/mL without fentanyl.
他の名前:
|
|
アクティブコンパレータ:Group 3
spinal fentanyl 15 micrograms plus bupivacaine 2.5mg followed by a PCEA infusion of fentanyl 2 micrograms/mL plus bupivacaine 0.625 mg/mL
|
A basal infusion rate for the PCEA will be set at 8 mL/h with patient administered boluses of 8 mL every 10 minutes and a one hour limit of 32 mL.
Breakthrough pain in all groups will be managed using anesthesiologist administered boluses of bupivacaine 1.25 mg/mL without fentanyl.
他の名前:
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Breastfeeding at 6 Weeks Post Delivery
時間枠:6 weeks post delivery
|
Breastfeeding continuing at 6 weeks after delivery of the baby.
|
6 weeks post delivery
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Breastfeeding at 3 Months After Delivery
時間枠:3 months after delivery
|
Breastfeeding at 3 months after delivery of baby
|
3 months after delivery
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Cumulative Fentanyl Dose (Micrograms)
時間枠:Time of epidural catheter removal
|
Total cumulative dose of fentanyl in micrograms
|
Time of epidural catheter removal
|
|
Plasma Fentanyl Concentration (ng/mL)
時間枠:Time of epidural catheter removal
|
Blood plasma fentanyl concentraton (nanograms/milliliter).
|
Time of epidural catheter removal
|
|
Umbilical Vein Plasma Fentanyl Concentration (ng/mL)
時間枠:Immediately after delivery
|
Umbilical venous blood plasma was analyzed for fentanyl concentration (ng/mL)
|
Immediately after delivery
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Paloma Toledo, M.D.,MPH、Northwestern University
出版物と役立つリンク
一般刊行物
- Baumgarder DJ, Muehl P, Fischer M, Pribbenow B. Effect of labor epidural anesthesia on breast-feeding of healthy full-term newborns delivered vaginally. J Am Board Fam Pract. 2003 Jan-Feb;16(1):7-13. doi: 10.3122/jabfm.16.1.7.
- Beilin Y, Bodian CA, Weiser J, Hossain S, Arnold I, Feierman DE, Martin G, Holzman I. Effect of labor epidural analgesia with and without fentanyl on infant breast-feeding: a prospective, randomized, double-blind study. Anesthesiology. 2005 Dec;103(6):1211-7. doi: 10.1097/00000542-200512000-00016.
- Jensen D, Wallace S, Kelsay P. LATCH: a breastfeeding charting system and documentation tool. J Obstet Gynecol Neonatal Nurs. 1994 Jan;23(1):27-32. doi: 10.1111/j.1552-6909.1994.tb01847.x.
- Rahm VA, Hallgren A, Hogberg H, Hurtig I, Odlind V. Plasma oxytocin levels in women during labor with or without epidural analgesia: a prospective study. Acta Obstet Gynecol Scand. 2002 Nov;81(11):1033-9. doi: 10.1034/j.1600-0412.2002.811107.x.
- Riordan J, Gross A, Angeron J, Krumwiede B, Melin J. The effect of labor pain relief medication on neonatal suckling and breastfeeding duration. J Hum Lact. 2000 Feb;16(1):7-12. doi: 10.1177/089033440001600103.
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。