- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT01074190
The Effect of Neuraxial Analgesia on Maternal Breastfeeding
A previous randomized trial showed a possible negative association with labor neuraxial analgesia with high compared to low doses of fentanyl, and breastfeeding at 6 weeks postpartum. The significance of this study would be to validate or refute these findings. In addition, we hope to better evaluate the impact of cumulative dose of fentanyl on breastfeeding success in the initial postpartum period as well as at 6 weeks and 6 months post delivery. In order to better assess the quality of breastfeeding, we will utilize a validated breastfeeding assessment tool, LATCH (Latch, Audible swallowing, Type of Nipple, Comfort, and Help). This validated tool can assess maternal and infant variables, define areas of needed intervention, and determine priorities in providing patient teaching. The LATCH assessment has been shown to be a predictor of breastfeeding duration. We also plan to vary the dosage of fentanyl analgesia to determine the relationship between doses below 150 micrograms and changes in breastfeeding assessments. If a clear association between decreased breastfeeding and total fentanyl is identified, then regimens to reduce cumulative doses of fentanyl can be developed to improve the likelihood of breastfeeding success in mothers that desire to breastfeed.
Prior observational studies have inferred epidurals negatively affect breastfeeding by decreasing maternal plasma oxytocin release which may adversely affect infant neurobehavioral development. In a study by Beilin et al., it was reported that mothers receiving a high cumulative dose (> 150 microgram) epidural fentanyl were more likely to have stopped nursing 6 weeks postpartum compared with groups receiving no fentanyl or those receiving < 150 microgram. The study however, was underpowered to detect differences in breastfeeding prior to hospital discharge. In addition, the breastfeeding assessment tool utilized resulted in binary assessments, and therefore, a global rating of the quality of breastfeeding was not available.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Participants in this study will be asked to complete a questionnaire called the Intrinsic Motivation Inventory (IMI).
Subjects will be randomized at the time they request neuraxial analgesia to one of three groups: Group 1: patient controlled epidural analgesia (PCEA) with bupivacaine 1mg/mL; Group 2: PCEA with fentanyl 1 mcg/mL plus bupivacaine 0.8 mg/mL; Group 3: PCEA with fentanyl 2 mcg/mL plus bupivacaine 0.625 mg/mL. Labor analgesia will be initiated in all groups using fentanyl 15 mcg plus bupivacaine 2.5 mg administered intrathecally. A basal infusion rate for the PCEA will be set at 8 mL/h with patient administered boluses of 8 mL every 10 minutes and a one hour limit of 32 mL. Breakthrough pain in all groups will be managed using anesthesiologist administered boluses of bupivacaine 1.25 mg/mL without fentanyl.
The patient as well as individuals who evaluate the study patient will be blinded to the group assignment. Samples of maternal venous blood ½ teaspoon (2 mls) and cord blood 2ml (1/2 teaspoon) will be collected after the delivery of the fetus. Blood concentrations of fentanyl and bupivacaine will be ascertained using high performance liquid chromatography (HPLC) analysis. Success of breastfeeding using the LATCH assessment tool will be measured by the lactation nurses within 24 hrs of delivery. At 6 weeks and at 3 months postpartum, follow-up phone calls by the anesthesia service will be made to assess for duration of breastfeeding. Also, the patient's obstetrician will be contacted to obtain the patient's Edinburgh Postnatal Depression Score to assess for postpartum depression, which may be a variable in decreasing breastfeeding success.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Illinois
-
Chicago, Illinois, États-Unis, 60611
- Northwestern University
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Age 18 and above
- English speaking
- Term gestation (> 38 weeks)
- Parous parturients presenting for attempted vaginal delivery with a cervical dilation less than 8 cm
- They must request neuraxial labor analgesia
- Have previously successfully breastfed their child postpartum for at least 6 weeks
- Are expressing an interest in exclusively breastfeeding postpartum
Exclusion Criteria:
- Under 18 years of age
- Parturients who have received parental opioids during labor or have taken opioids prenatally
- Patients whose neuraxial analgesia failed due to abnormal spinal anatomy including scoliosis or previous spinal instrumentation
- Supplemental epidural opioids during labor
- Had an expedited labor with the delivery of the fetus less than 90 minutes from the placement of the neuraxial anesthestic
- Underwent cesarean delivery
- Received general analgesia for an unanticipated postpartum procedure
- Dropout criteria include patients who wished to be taken out of the study or were lost to follow-up
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Double
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Group 1
spinal fentanyl 15 micrograms plus bupivacaine 2.5 mg followed by a patient controlled epidural analgesia (PCEA) maintenance infusion of bupivacaine 1mg/mL
|
A basal infusion rate for the PCEA will be set at 8 mL/h with patient administered boluses of 8 mL every 10 minutes and a one hour limit of 32 mL.
Breakthrough pain in all groups will be managed using anesthesiologist administered boluses of bupivacaine 1.25 mg/mL without fentanyl.
Autres noms:
|
|
Expérimental: Group 2
spinal fentanyl 15 micrograms plus bupivacaine 2.5 mg spinal followed by a PCEA infusion of fentanyl 1 micrograms/mL plus bupivacaine 0.8 mg/mL
|
A basal infusion rate for the PCEA will be set at 8 mL/h with patient administered boluses of 8 mL every 10 minutes and a one hour limit of 32 mL.
Breakthrough pain in all groups will be managed using anesthesiologist administered boluses of bupivacaine 1.25 mg/mL without fentanyl.
Autres noms:
|
|
Comparateur actif: Group 3
spinal fentanyl 15 micrograms plus bupivacaine 2.5mg followed by a PCEA infusion of fentanyl 2 micrograms/mL plus bupivacaine 0.625 mg/mL
|
A basal infusion rate for the PCEA will be set at 8 mL/h with patient administered boluses of 8 mL every 10 minutes and a one hour limit of 32 mL.
Breakthrough pain in all groups will be managed using anesthesiologist administered boluses of bupivacaine 1.25 mg/mL without fentanyl.
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Breastfeeding at 6 Weeks Post Delivery
Délai: 6 weeks post delivery
|
Breastfeeding continuing at 6 weeks after delivery of the baby.
|
6 weeks post delivery
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Breastfeeding at 3 Months After Delivery
Délai: 3 months after delivery
|
Breastfeeding at 3 months after delivery of baby
|
3 months after delivery
|
Autres mesures de résultats
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Cumulative Fentanyl Dose (Micrograms)
Délai: Time of epidural catheter removal
|
Total cumulative dose of fentanyl in micrograms
|
Time of epidural catheter removal
|
|
Plasma Fentanyl Concentration (ng/mL)
Délai: Time of epidural catheter removal
|
Blood plasma fentanyl concentraton (nanograms/milliliter).
|
Time of epidural catheter removal
|
|
Umbilical Vein Plasma Fentanyl Concentration (ng/mL)
Délai: Immediately after delivery
|
Umbilical venous blood plasma was analyzed for fentanyl concentration (ng/mL)
|
Immediately after delivery
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Paloma Toledo, M.D.,MPH, Northwestern University
Publications et liens utiles
Publications générales
- Baumgarder DJ, Muehl P, Fischer M, Pribbenow B. Effect of labor epidural anesthesia on breast-feeding of healthy full-term newborns delivered vaginally. J Am Board Fam Pract. 2003 Jan-Feb;16(1):7-13. doi: 10.3122/jabfm.16.1.7.
- Beilin Y, Bodian CA, Weiser J, Hossain S, Arnold I, Feierman DE, Martin G, Holzman I. Effect of labor epidural analgesia with and without fentanyl on infant breast-feeding: a prospective, randomized, double-blind study. Anesthesiology. 2005 Dec;103(6):1211-7. doi: 10.1097/00000542-200512000-00016.
- Jensen D, Wallace S, Kelsay P. LATCH: a breastfeeding charting system and documentation tool. J Obstet Gynecol Neonatal Nurs. 1994 Jan;23(1):27-32. doi: 10.1111/j.1552-6909.1994.tb01847.x.
- Rahm VA, Hallgren A, Hogberg H, Hurtig I, Odlind V. Plasma oxytocin levels in women during labor with or without epidural analgesia: a prospective study. Acta Obstet Gynecol Scand. 2002 Nov;81(11):1033-9. doi: 10.1034/j.1600-0412.2002.811107.x.
- Riordan J, Gross A, Angeron J, Krumwiede B, Melin J. The effect of labor pain relief medication on neonatal suckling and breastfeeding duration. J Hum Lact. 2000 Feb;16(1):7-12. doi: 10.1177/089033440001600103.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
- Effets physiologiques des médicaments
- Dépresseurs du système nerveux central
- Agents du système nerveux périphérique
- Analgésiques
- Agents du système sensoriel
- Anesthésiques intraveineux
- Anesthésiques, général
- Anesthésiques
- Analgésiques, Opioïdes
- Stupéfiants
- Adjuvants, Anesthésie
- Anesthésiques locaux
- Fentanyl
- Bupivacaïne
Autres numéros d'identification d'étude
- STU00007275
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .