Comparison of Cardiac Output With LiDCO Rapid and TEE Against Thermodilution Technique in Cardiac Surgery
Validation of Measurement of Cardiac Output With LiDCO Rapid and TEE (Trans Esophageal Echocardiography) by Comparing With Intermittent Thermodilution Technique in Cardiac Surgical Patients
調査の概要
状態
条件
詳細な説明
Measurement of the cardiac output is one of the important hemodynamic monitoring tools in cardiac surgery. It helps determine the type of medications needed to maintain optimal hemodynamic status in the entire perioperative period. Thermodilution method using pulmonary artery catheter is considered has the gold standard for the measurement of cardiac output, however over the past 10 to 15 years it has been questioned about its safety and efficacy. There has been a surge in recent years of less invasive devices capable of measuring cardiac output by various means, including bioimpedance, transpulmonary thermodilution, transthoracic and transesophageal echocardiography, and arterial waveform analysis.
There is a variety of devices currently available for cardiac output measurement by arterial-waveform analysis. These devices have been compared to each other, and to the pulmonary artery catheter as the gold standard. However, the companies manufacturing these devices have made software upgrades that they believe improves their performance. No studies have been performed comparing the uncalibrated arterial waveform based cardiac output measurement device,LiDCORapid since the software upgrades. In addition to baseline cardiac output measurements, Investigators intend to study the effect of volume loading (by trendelenburg position), sympathetic stimulus (incision), a vasodilated state (15 minutes after separation from CPB) and chest closure on cardiac output measured by the three different techniques.
In addition to cardiac output the investigators would like to measure stroke volume ,Systemic Vascular Resistance, stroke volume variation with LiDCO . The main purpose is to validate the accuracy of measurements by these two minimally-invasive methods in comparison with thermodilution method in various hemodynamic states.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
Iowa
-
Iowa City、Iowa、アメリカ、52242
- University of Iowa
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Elective cardiac procedures other than those specified in the exclusion criteria
Exclusion Criteria:
- All emergency cardiac procedures, prisoners and pregnant women, patients who are scheduled for ventricular assist devices and those with severe aortic, mitral and tricuspid insufficiency will be excluded.
研究計画
研究はどのように設計されていますか?
デザインの詳細
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
The primary objective of the study is measured cardiac output by LiDCO Rapid is as equivalent ( within 30%) as measured by pulmonary artery catheter using intermittent thermodilution method among patients undergoing elective cardiac surgery.
時間枠:During intraoperative period.
|
During intraoperative period.
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
The secondary objective of the study is measured cardiac output by TEE using VTI at LVOT is as equivalent ( within 30%) as measured by pulmonary artery catheter using intermittent thermodilution method among patients undergoing elective cardiac surgery.
時間枠:During intraoperative period
|
During intraoperative period
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Sudhakar Subramani, M.D.、University of Iowa
出版物と役立つリンク
一般刊行物
- Hadian M, Kim HK, Severyn DA, Pinsky MR. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care. 2010;14(6):R212. doi: 10.1186/cc9335. Epub 2010 Nov 23.
- Cecconi M, Dawson D, Casaretti R, Grounds RM, Rhodes A. A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution. Minerva Anestesiol. 2010 Dec;76(12):1010-7. Epub 2010 Jul 16.
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。