Comparison of Cardiac Output With LiDCO Rapid and TEE Against Thermodilution Technique in Cardiac Surgery
Validation of Measurement of Cardiac Output With LiDCO Rapid and TEE (Trans Esophageal Echocardiography) by Comparing With Intermittent Thermodilution Technique in Cardiac Surgical Patients
Aperçu de l'étude
Statut
Les conditions
Description détaillée
Measurement of the cardiac output is one of the important hemodynamic monitoring tools in cardiac surgery. It helps determine the type of medications needed to maintain optimal hemodynamic status in the entire perioperative period. Thermodilution method using pulmonary artery catheter is considered has the gold standard for the measurement of cardiac output, however over the past 10 to 15 years it has been questioned about its safety and efficacy. There has been a surge in recent years of less invasive devices capable of measuring cardiac output by various means, including bioimpedance, transpulmonary thermodilution, transthoracic and transesophageal echocardiography, and arterial waveform analysis.
There is a variety of devices currently available for cardiac output measurement by arterial-waveform analysis. These devices have been compared to each other, and to the pulmonary artery catheter as the gold standard. However, the companies manufacturing these devices have made software upgrades that they believe improves their performance. No studies have been performed comparing the uncalibrated arterial waveform based cardiac output measurement device,LiDCORapid since the software upgrades. In addition to baseline cardiac output measurements, Investigators intend to study the effect of volume loading (by trendelenburg position), sympathetic stimulus (incision), a vasodilated state (15 minutes after separation from CPB) and chest closure on cardiac output measured by the three different techniques.
In addition to cardiac output the investigators would like to measure stroke volume ,Systemic Vascular Resistance, stroke volume variation with LiDCO . The main purpose is to validate the accuracy of measurements by these two minimally-invasive methods in comparison with thermodilution method in various hemodynamic states.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
Iowa
-
Iowa City, Iowa, États-Unis, 52242
- University of Iowa
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Elective cardiac procedures other than those specified in the exclusion criteria
Exclusion Criteria:
- All emergency cardiac procedures, prisoners and pregnant women, patients who are scheduled for ventricular assist devices and those with severe aortic, mitral and tricuspid insufficiency will be excluded.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
The primary objective of the study is measured cardiac output by LiDCO Rapid is as equivalent ( within 30%) as measured by pulmonary artery catheter using intermittent thermodilution method among patients undergoing elective cardiac surgery.
Délai: During intraoperative period.
|
During intraoperative period.
|
Mesures de résultats secondaires
Mesure des résultats |
Délai |
|---|---|
|
The secondary objective of the study is measured cardiac output by TEE using VTI at LVOT is as equivalent ( within 30%) as measured by pulmonary artery catheter using intermittent thermodilution method among patients undergoing elective cardiac surgery.
Délai: During intraoperative period
|
During intraoperative period
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Sudhakar Subramani, M.D., University of Iowa
Publications et liens utiles
Publications générales
- Hadian M, Kim HK, Severyn DA, Pinsky MR. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care. 2010;14(6):R212. doi: 10.1186/cc9335. Epub 2010 Nov 23.
- Cecconi M, Dawson D, Casaretti R, Grounds RM, Rhodes A. A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution. Minerva Anestesiol. 2010 Dec;76(12):1010-7. Epub 2010 Jul 16.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 201205760
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .