Comparison of Cardiac Output With LiDCO Rapid and TEE Against Thermodilution Technique in Cardiac Surgery
Validation of Measurement of Cardiac Output With LiDCO Rapid and TEE (Trans Esophageal Echocardiography) by Comparing With Intermittent Thermodilution Technique in Cardiac Surgical Patients
Обзор исследования
Статус
Условия
Подробное описание
Measurement of the cardiac output is one of the important hemodynamic monitoring tools in cardiac surgery. It helps determine the type of medications needed to maintain optimal hemodynamic status in the entire perioperative period. Thermodilution method using pulmonary artery catheter is considered has the gold standard for the measurement of cardiac output, however over the past 10 to 15 years it has been questioned about its safety and efficacy. There has been a surge in recent years of less invasive devices capable of measuring cardiac output by various means, including bioimpedance, transpulmonary thermodilution, transthoracic and transesophageal echocardiography, and arterial waveform analysis.
There is a variety of devices currently available for cardiac output measurement by arterial-waveform analysis. These devices have been compared to each other, and to the pulmonary artery catheter as the gold standard. However, the companies manufacturing these devices have made software upgrades that they believe improves their performance. No studies have been performed comparing the uncalibrated arterial waveform based cardiac output measurement device,LiDCORapid since the software upgrades. In addition to baseline cardiac output measurements, Investigators intend to study the effect of volume loading (by trendelenburg position), sympathetic stimulus (incision), a vasodilated state (15 minutes after separation from CPB) and chest closure on cardiac output measured by the three different techniques.
In addition to cardiac output the investigators would like to measure stroke volume ,Systemic Vascular Resistance, stroke volume variation with LiDCO . The main purpose is to validate the accuracy of measurements by these two minimally-invasive methods in comparison with thermodilution method in various hemodynamic states.
Тип исследования
Регистрация (Действительный)
Контакты и местонахождение
Места учебы
-
-
Iowa
-
Iowa City, Iowa, Соединенные Штаты, 52242
- University of Iowa
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Метод выборки
Исследуемая популяция
Описание
Inclusion Criteria:
- Elective cardiac procedures other than those specified in the exclusion criteria
Exclusion Criteria:
- All emergency cardiac procedures, prisoners and pregnant women, patients who are scheduled for ventricular assist devices and those with severe aortic, mitral and tricuspid insufficiency will be excluded.
Учебный план
Как устроено исследование?
Детали дизайна
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
The primary objective of the study is measured cardiac output by LiDCO Rapid is as equivalent ( within 30%) as measured by pulmonary artery catheter using intermittent thermodilution method among patients undergoing elective cardiac surgery.
Временное ограничение: During intraoperative period.
|
During intraoperative period.
|
Вторичные показатели результатов
Мера результата |
Временное ограничение |
|---|---|
|
The secondary objective of the study is measured cardiac output by TEE using VTI at LVOT is as equivalent ( within 30%) as measured by pulmonary artery catheter using intermittent thermodilution method among patients undergoing elective cardiac surgery.
Временное ограничение: During intraoperative period
|
During intraoperative period
|
Соавторы и исследователи
Спонсор
Следователи
- Главный следователь: Sudhakar Subramani, M.D., University of Iowa
Публикации и полезные ссылки
Общие публикации
- Hadian M, Kim HK, Severyn DA, Pinsky MR. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit Care. 2010;14(6):R212. doi: 10.1186/cc9335. Epub 2010 Nov 23.
- Cecconi M, Dawson D, Casaretti R, Grounds RM, Rhodes A. A prospective study of the accuracy and precision of continuous cardiac output monitoring devices as compared to intermittent thermodilution. Minerva Anestesiol. 2010 Dec;76(12):1010-7. Epub 2010 Jul 16.
Даты записи исследования
Изучение основных дат
Начало исследования
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Оценивать)
Обновления учебных записей
Последнее опубликованное обновление (Оценивать)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- 201205760
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .