Effects of Catheter Ablation on Burden of Atrial Fibrillation (MRICEMAN) (MRICEMAN)
A Nationwide Multicenter Trial Assessing the Effects of Catheter Ablation on Burden of Atrial Fibrillation Recorded by Implantable Cardiac Monitor
調査の概要
詳細な説明
A total of 300 patients will be randomized to three different catheter ablation techniques (100 patients/group); radiofrequency ablation using remote magnet navigation, radiofrequency ablation using manual method, and cryoablation. A loop recorder (REVEAL) is implanted one month before the catheter ablation of paroxysmal atrial fibrillation and the effects of atrial fibrillation burden will be compared between the three methods at 12 and 24 months after ablation excluding the first three months´ blanking period.
The primary endpoints are:
- the proportion of patients remaining free from atrial fibrillation, atrial flutter or atrial tachycardia (> 2 minutes) recorded by the implantable cardiac monitor (Medtronic) at 24 months follow-up and
- total atrial fibrillation burden recorded by the loop recorder.
Other endpoints:
- Atrial fibrillation burden in 7 days Holter recording at 12 and 24 months compared to baseline,
- the time to first documented symptomatic and asymptomatic recurrence of atrial fibrillation
- prescription of antiarrhythmic drugs after the 3 months blanking period following the ablation
- re-ablation after the index ablation procedure,
- total procedural duration;
- total time of fluoroscopy and radiation dose;
- number and duration of cardiovascular hospitalization;
- quality of life questionnaires at 12 months and 24 month compared with baseline,
- cognitive function at 12 and 24 month compared with baseline,
- cost-efficacy of the different ablation techniques.
研究の種類
入学 (予想される)
段階
- フェーズ 4
連絡先と場所
研究場所
-
-
-
Oulu、フィンランド、90014
- UOulu
-
Oulu、フィンランド
- Heikki Huikuri
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion criteria:
- Patients with symptomatic paroxysmal atrial fibrillation fulfilling the contemporary guideline criteria for AF ablation
Exclusion Criteria:
- Any contraindication to catheter ablation
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:manual radiofrequency ablation
Radiofrequency catheter ablation using manual catheter manipulation will be used as an ablation technique.
|
Three different catheter ablation techniques will be used aimed at isolating the pulmonary veins from left atrium.The endpoint is defined as absence or dissociation of all pulmonary vein potentials as confirmed by the circular mapping catheter after a waiting period of 30 minutes after the last ablation.
The use of adenosine or isoproterenol to detect concealed pulmonary vein conduction is voluntary.
|
|
アクティブコンパレータ:magnet navigation ablation
Radiofrequency catheter ablation using remote magnet navigation will be used as an ablation technique.
|
Three different catheter ablation techniques will be used aimed at isolating the pulmonary veins from left atrium.The endpoint is defined as absence or dissociation of all pulmonary vein potentials as confirmed by the circular mapping catheter after a waiting period of 30 minutes after the last ablation.
The use of adenosine or isoproterenol to detect concealed pulmonary vein conduction is voluntary.
|
|
アクティブコンパレータ:cryoablation
Catheter ablation using cryoablation technique will be used as an ablation technique of atrial fibrillation.
|
Three different catheter ablation techniques will be used aimed at isolating the pulmonary veins from left atrium.The endpoint is defined as absence or dissociation of all pulmonary vein potentials as confirmed by the circular mapping catheter after a waiting period of 30 minutes after the last ablation.
The use of adenosine or isoproterenol to detect concealed pulmonary vein conduction is voluntary.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Free of atrial fibrillation
時間枠:24 months
|
the proportion of patients remaining free from AF, atrial flutter (AFL) or atrial tachycardia (AT) (> 2 minutes) recorded by the implantable cardiac monitor (ICM, Reveal, Medtronic Co.) at 24 months.
|
24 months
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Total AF burden
時間枠:24 months
|
total AF burden recorded by the implantable loop recorder during the 24 month follow-up.
|
24 months
|
|
Incidence of adverse events
時間枠:24 months
|
Safety is one of the secondary endpoints. The following potential adverse events will be monitored: Any previous left atrial ablation or surgery Any cardiac surgery or percutaneous coronary intervention within three months prior to enrolment. Secondary AF Stroke or transient ischemic attack within six months prior to enrolment Myocardial infarction within three months prior to enrolment Left ventricular ejection fraction < 40 % Anteroposterior left atrial diameter >55 mm by transthoracic or transesophageal echocardiography Implanted prosthetic valve |
24 months
|
協力者と研究者
出版物と役立つリンク
便利なリンク
研究記録日
主要日程の研究
研究開始
一次修了 (予想される)
研究の完了 (予想される)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (見積もり)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。