Relief From Side Effects: Clinical Use of Electrodes With Direction (RESCUED)
2019年1月6日 更新者:Christopher Honey、University of British Columbia
Relief From Side Effects: Clinical Use of Electrodes With Direction: a Prospective, Open Label, Clinical Trial for Thalamic Deep Brain Stimulation
Deep Brain Stimulation (DBS) uses electrical pulses sent through a lead (insulated wire) to help stop unwanted symptoms in a variety of brain diseases, including the tremor seen in patients with Essential Tremor (ET).
The current standard lead allows this stimulation to spread out uniformly in all directions.
As these diseases progress, however, the amount of electrical stimulation required to stop the symptom usually increases.
This may become problematic because the increased electrical stimulation required for advanced symptoms may spread outside the desired targeted area, and effect other parts of the brain and causing unwanted side effects.
A new type of DBS lead has been developed which can steer, or focus, the electrical stimulation in a given direction toward the desired target area and away from areas that would cause side effects.
We would like to quantify the benefit seen in patients who have been switched from the traditional lead to this new directional lead.
調査の概要
状態
わからない
詳細な説明
Patients implanted with a DBS may experience unwanted side effects such as motor contractures, paresthesia, or dysarthria.
This occurs when the electrical field of the stimulation spreads out beyond the targeted area.
This is especially common in patients whose disease has progressed, and must use increasingly higher currents in order to regain control of their tremor.
Unfortunately, because the electrical field affects neurons in a symmetrical sphere around the DBS, it is often impossible to reach the additional desired neuronal elements without simultaneously affecting equidistant brain regions responsible for side effects.
For many of our advanced patients, this means choosing between a debilitating tremor or disabling side effects.The directional lead is a FDA and Health Canada approved DBS lead which features radially segmented electrodes which can selectively steer the electrical field in a predefined direction, orthogonal to the lead trajectory.
This will allow DBS clinicians to steer current towards desired structural areas, while avoiding locations, which produce negative side effects.
研究の種類
介入
入学 (予想される)
6
段階
- 適用できない
連絡先と場所
このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。
研究場所
-
-
British Columbia
-
Vancouver、British Columbia、カナダ、V5Z 4E3
- 募集
- The Vancouver General Hospital
-
コンタクト:
- Christopher R Honey, MD, DPhil
- 電話番号:604.875.5894
- メール:chris.honey@telus.net
-
-
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
18年~80年 (大人、高齢者)
健康ボランティアの受け入れ
いいえ
受講資格のある性別
全て
説明
Inclusion Criteria:
- Participants must have been implanted with the DBS
- Participants must have been diagnosed with Essential Tremor
- Participants must experience negative side effects from their DBS which limit control over their tremor
- Participants must be able to receive benefit from their stimulator, but at the cost of negative side effects
Exclusion Criteria:
- All individuals who meet criteria outlined in "inclusion criteria" may be eligible for this study
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Treatment
Patients who were previously implanted with a traditional DBS lead and have subsequently developed stimulation induced side effects will gain significantly more tremor control without side effects when re-implanted with a directional DBS lead.
We expect these patients' quality of life will improve.
These patients typically will have had significant tremor relief (greater than 75% reduction from preoperative tremor rating scale) without side effects at their one year post operative follow-up.
With the expected disease progression they will have had to increase their DBS stimulation to the degree that their DBS now causes side effects in order to block their tremor
|
Individuals in this arm will have their stimulator settings programmed to the point in which they have maximum tremor control with no side effects.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Tremor Control
時間枠:Assessed once all tests performed - 1 to 2 months post-operatively
|
Maximum percentage change in tremor (as measured by the Tremor Rating Scale) without side-effects (comparing DBS "on" versus "off") in each patient using the standard lead compared to the directional lead.
|
Assessed once all tests performed - 1 to 2 months post-operatively
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Quality of life based on participant's best real life setting
時間枠:Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
Quality of life will be based on each participant's subjective opinion using the Short Form 36 (SF36) (a patient-reported survey focusing on health and quality of life) assessment form.
|
Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
|
Quality of life based on tremor management participant's best real life setting
時間枠:Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
Quality of life will be based on each participant's subjective opinion using the Quality of Life in Essential Tremor Questionare.
|
Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
|
Quality of life based on voice handicap with participant's best real life setting
時間枠:Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
Quality of life will be based on each participant's subjective opinion using the Vocal handicap Index scale.
|
Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
出版物と役立つリンク
研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。
一般刊行物
- Toader E, Decre MM, Martens HC. Steering deep brain stimulation fields using a high resolution electrode array. Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:2061-4. doi: 10.1109/IEMBS.2010.5626472.
- Reinacher PC, Kruger MT, Coenen VA, Shah M, Roelz R, Jenkner C, Egger K. Determining the Orientation of Directional Deep Brain Stimulation Electrodes Using 3D Rotational Fluoroscopy. AJNR Am J Neuroradiol. 2017 Jun;38(6):1111-1116. doi: 10.3174/ajnr.A5153. Epub 2017 Apr 6.
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始 (実際)
2018年9月17日
一次修了 (予想される)
2019年7月1日
研究の完了 (予想される)
2019年8月1日
試験登録日
最初に提出
2018年9月17日
QC基準を満たした最初の提出物
2019年1月6日
最初の投稿 (実際)
2019年1月8日
学習記録の更新
投稿された最後の更新 (実際)
2019年1月8日
QC基準を満たした最後の更新が送信されました
2019年1月6日
最終確認日
2019年1月1日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。