- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT03795935
Relief From Side Effects: Clinical Use of Electrodes With Direction (RESCUED)
6 janvier 2019 mis à jour par: Christopher Honey, University of British Columbia
Relief From Side Effects: Clinical Use of Electrodes With Direction: a Prospective, Open Label, Clinical Trial for Thalamic Deep Brain Stimulation
Deep Brain Stimulation (DBS) uses electrical pulses sent through a lead (insulated wire) to help stop unwanted symptoms in a variety of brain diseases, including the tremor seen in patients with Essential Tremor (ET).
The current standard lead allows this stimulation to spread out uniformly in all directions.
As these diseases progress, however, the amount of electrical stimulation required to stop the symptom usually increases.
This may become problematic because the increased electrical stimulation required for advanced symptoms may spread outside the desired targeted area, and effect other parts of the brain and causing unwanted side effects.
A new type of DBS lead has been developed which can steer, or focus, the electrical stimulation in a given direction toward the desired target area and away from areas that would cause side effects.
We would like to quantify the benefit seen in patients who have been switched from the traditional lead to this new directional lead.
Aperçu de l'étude
Statut
Inconnue
Les conditions
Intervention / Traitement
Description détaillée
Patients implanted with a DBS may experience unwanted side effects such as motor contractures, paresthesia, or dysarthria.
This occurs when the electrical field of the stimulation spreads out beyond the targeted area.
This is especially common in patients whose disease has progressed, and must use increasingly higher currents in order to regain control of their tremor.
Unfortunately, because the electrical field affects neurons in a symmetrical sphere around the DBS, it is often impossible to reach the additional desired neuronal elements without simultaneously affecting equidistant brain regions responsible for side effects.
For many of our advanced patients, this means choosing between a debilitating tremor or disabling side effects.The directional lead is a FDA and Health Canada approved DBS lead which features radially segmented electrodes which can selectively steer the electrical field in a predefined direction, orthogonal to the lead trajectory.
This will allow DBS clinicians to steer current towards desired structural areas, while avoiding locations, which produce negative side effects.
Type d'étude
Interventionnel
Inscription (Anticipé)
6
Phase
- N'est pas applicable
Contacts et emplacements
Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.
Lieux d'étude
-
-
British Columbia
-
Vancouver, British Columbia, Canada, V5Z 4E3
- Recrutement
- The Vancouver General Hospital
-
Contact:
- Christopher R Honey, MD, DPhil
- Numéro de téléphone: 604.875.5894
- E-mail: chris.honey@telus.net
-
-
Critères de participation
Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.
Critère d'éligibilité
Âges éligibles pour étudier
18 ans à 80 ans (Adulte, Adulte plus âgé)
Accepte les volontaires sains
Non
Sexes éligibles pour l'étude
Tout
La description
Inclusion Criteria:
- Participants must have been implanted with the DBS
- Participants must have been diagnosed with Essential Tremor
- Participants must experience negative side effects from their DBS which limit control over their tremor
- Participants must be able to receive benefit from their stimulator, but at the cost of negative side effects
Exclusion Criteria:
- All individuals who meet criteria outlined in "inclusion criteria" may be eligible for this study
Plan d'étude
Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Treatment
Patients who were previously implanted with a traditional DBS lead and have subsequently developed stimulation induced side effects will gain significantly more tremor control without side effects when re-implanted with a directional DBS lead.
We expect these patients' quality of life will improve.
These patients typically will have had significant tremor relief (greater than 75% reduction from preoperative tremor rating scale) without side effects at their one year post operative follow-up.
With the expected disease progression they will have had to increase their DBS stimulation to the degree that their DBS now causes side effects in order to block their tremor
|
Individuals in this arm will have their stimulator settings programmed to the point in which they have maximum tremor control with no side effects.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Tremor Control
Délai: Assessed once all tests performed - 1 to 2 months post-operatively
|
Maximum percentage change in tremor (as measured by the Tremor Rating Scale) without side-effects (comparing DBS "on" versus "off") in each patient using the standard lead compared to the directional lead.
|
Assessed once all tests performed - 1 to 2 months post-operatively
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Quality of life based on participant's best real life setting
Délai: Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
Quality of life will be based on each participant's subjective opinion using the Short Form 36 (SF36) (a patient-reported survey focusing on health and quality of life) assessment form.
|
Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
|
Quality of life based on tremor management participant's best real life setting
Délai: Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
Quality of life will be based on each participant's subjective opinion using the Quality of Life in Essential Tremor Questionare.
|
Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
|
Quality of life based on voice handicap with participant's best real life setting
Délai: Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
Quality of life will be based on each participant's subjective opinion using the Vocal handicap Index scale.
|
Assessed during study visits - The initial assessment will occur during a pre-operative study visit which will be compared post operatively 3 months after outcome 1 has been measured
|
Collaborateurs et enquêteurs
C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.
Parrainer
Collaborateurs
Publications et liens utiles
La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.
Publications générales
- Toader E, Decre MM, Martens HC. Steering deep brain stimulation fields using a high resolution electrode array. Annu Int Conf IEEE Eng Med Biol Soc. 2010;2010:2061-4. doi: 10.1109/IEMBS.2010.5626472.
- Reinacher PC, Kruger MT, Coenen VA, Shah M, Roelz R, Jenkner C, Egger K. Determining the Orientation of Directional Deep Brain Stimulation Electrodes Using 3D Rotational Fluoroscopy. AJNR Am J Neuroradiol. 2017 Jun;38(6):1111-1116. doi: 10.3174/ajnr.A5153. Epub 2017 Apr 6.
Dates d'enregistrement des études
Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.
Dates principales de l'étude
Début de l'étude (Réel)
17 septembre 2018
Achèvement primaire (Anticipé)
1 juillet 2019
Achèvement de l'étude (Anticipé)
1 août 2019
Dates d'inscription aux études
Première soumission
17 septembre 2018
Première soumission répondant aux critères de contrôle qualité
6 janvier 2019
Première publication (Réel)
8 janvier 2019
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
8 janvier 2019
Dernière mise à jour soumise répondant aux critères de contrôle qualité
6 janvier 2019
Dernière vérification
1 janvier 2019
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- H17-00672
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
NON
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Non
Étudie un produit d'appareil réglementé par la FDA américaine
Non
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .