Posterior Flap Hydration of Clear Corneal Incisions in Cataract Surgery: Influence on Corneal Wound Tightness and Architecture (CCI hydration)
Posterior Flap Hydration of Clear Corneal Incisions: Influence on Wound Tightness and Architecture
Sutureless clear corneal incision (CCI) is the most commonly used technique for creating an entrance wound in cataract surgery. Corneal incision hydration enhances wound tightness and reduces postoperative fluid suction from the ocular surface into the anterior chamber; thereby, loweres the risk of postoperative endophthalmitis. Various hydration methods have been employed to close corneal incisions. Standard CCI hydration may be ineffective in sutureless incisions with central wound gaping.
Authors described a new technique of hydration: a posterior flap hydration technique. This study evaluates its effect on corneal wound tightness immediately after hydration, and assess wound architecture on the first postoperative day using anterior segment optical coherence tomography (AS-OCT).
調査の概要
詳細な説明
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Czechia
-
Pilsen、Czechia、チェコ、30100
- University Hospital Pilsen
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- cataract
- visible central wound gap of CCI at the end of the surgery
Exclusion Criteria:
- any other ocular pathology
- serious systhemic diseases
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Central wound gap of CCI
Patient with visible central wound gap of the CCI were treated with posterial flap hydration. Standard hydrodissection and hydrodelineation cannulas are used for hydration. Cannulas with flat ends, including the cortical cleaving hydrodissector 27 G × 7/8 (BVI Visitec) and a hydrodissector 27 G × 7/8 (Sterimedix Ltd.), are employed. The morphology of the central wound before and after hydration is evaluated using video recordings. On the first postoperative day (20-24 hours after surgery), anterior segment optical coherence tomography (AS-OCT) analysis of corneal incisions is performed with a Tomey Casia 2 device using the Post-op Cataract AS Global Scan application. |
Patient with visible central wound gap of the CCI were treated with posterial flap hydration. Standard hydrodissection and hydrodelineation cannulas are used for hydration. Cannulas with flat ends, including the cortical cleaving hydrodissector 27 G × 7/8 (BVI Visitec) and a hydrodissector 27 G × 7/8 (Sterimedix Ltd.), are employed. The morphology of the central wound before and after hydration is evaluated using video recordings. On the first postoperative day (20-24 hours after surgery), anterior segment optical coherence tomography (AS-OCT) analysis of corneal incisions is performed with a Tomey Casia 2 device using the Post-op Cataract AS Global Scan application. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
posterior flap hydration
時間枠:1 day after surgery
|
The Primary Outcome Measure is to evaluate the tightness of the corneal wound after the posterior flap hydration peroperatively (at the end fo the surgery) - no leakage of the intraocular fluid schould by observed after the hydration.
|
1 day after surgery
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Corneal wound morphology on the first postoperative day
時間枠:20-24 hours after surgery
|
The other Outcome Measure is the corneal wound morphology on the first postoperative day (20-24 hours after surgery) using anterior segment optical coherence tomography (AS-OCT).
The corneal incision pathology (central wound gaping, posterior flap prominence, tongue eversion, tongue retraction and focal Descemet's membrane detachment ) will be serached on OCT pictures and their incidence among study patients will be reported as a percentage (%).
|
20-24 hours after surgery
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- Posterior flap hydration
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。