このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Gemini Flash 3.6 Versus Human Observers for FIGO-Based Interpretation of Intrapartum Cardiotocography

2026年9月14日 更新者:Abdelrhman Ahmed Kamel、Assiut University

Gemini Flash 3.6 Versus Human Observers for FIGO-Based Interpretation of Intrapartum Cardiotocography: A Diagnostic Accuracy Study

Cardiotocography (CTG) is the standard method for monitoring fetal heart rate and uterine contractions during labor to detect signs of fetal hypoxia. However, human CTG interpretation is often subjective and subject to high interobserver variability, even among experienced clinicians. Multimodal artificial intelligence (AI) models have emerged as potential diagnostic aids capable of evaluating CTG tracings. This prospective diagnostic accuracy study aims to evaluate the diagnostic performance of Gemini Flash 3.6 in interpreting intrapartum CTG recordings according to the 2015 International Federation of Gynecology and Obstetrics (FIGO) guidelines, and to compare its accuracy directly against independent human expert obstetricians.

Participants include pregnant women admitted in active labor at term with a singleton cephalic pregnancy undergoing continuous CTG monitoring. De-identified digital images of the final 60 minutes of CTG tracing prior to delivery will be independently evaluated by Gemini Flash 3.6 and three expert obstetricians. Each evaluator will classify the tracings into one of three FIGO categories: Normal, Suspicious, or Pathological. All evaluators will be blinded to clinical details, delivery outcomes, and other observers' interpretations.

The primary objective is to assess the diagnostic sensitivity of Gemini Flash 3.6 in identifying neonates with a 5-minute Apgar score less than 7. Secondary objectives include comparing the diagnostic performance of the AI model with that of individual expert obstetricians, measuring interobserver agreement among all raters, and assessing associations with 1-minute Apgar scores and umbilical artery blood gas parameters. The AI model will be used solely as an investigational research tool, and its evaluations will not be available to the clinical team or used to guide patient care.

調査の概要

状態

まだ募集していません

研究の種類

観察的

入学 (推定)

415

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

なし

サンプリング方法

非確率サンプル

調査対象母集団

Pregnant women admitted in active labor at term (gestational age 37+0 weeks or greater) with singleton pregnancies in cephalic presentation undergoing routine continuous intrapartum cardiotocography (CTG) monitoring at Abutig Specialized Hospital and Women's Health Hospital, Assiut University, Egypt.

説明

Inclusion Criteria:

  • Singleton pregnancy
  • Gestational age 37+0 weeks or greater
  • Cephalic fetal presentation
  • Admission to the labor ward in active labor
  • Continuous intrapartum cardiotocography (CTG) monitoring
  • Availability of an interpretable CTG tracing immediately preceding delivery
  • Availability of documented 1-minute and 5-minute Apgar scores
  • Written informed consent obtained prior to enrollment

Exclusion Criteria:

  • Multiple pregnancy
  • Major fetal congenital anomalies
  • Antepartum stillbirth
  • Elective cesarean delivery performed before the onset of labor without an adequate intrapartum CTG tracing
  • CTG tracing with inadequate technical quality, including signal loss of 15% or greater
  • Missing 5-minute Apgar score
  • Technical problems preventing standardized CTG image preparation or interpretation

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
Intrapartum CTG Monitoring Cohort
Women with singleton term pregnancies (gestational age ≥ 37 + 0 weeks) in cephalic presentation admitted to the labor ward in active labor who undergo routine continuous intrapartum cardiotocography (CTG) monitoring immediately preceding delivery. De-identified digital CTG tracings from this cohort are independently evaluated by Gemini Flash 3.6 and three expert obstetricians according to the 2015 FIGO consensus guidelines, and validated against neonatal outcomes including 1-minute and 5-minute Apgar scores as well as umbilical artery blood-gas analysis where available.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Sensitivity of Gemini Flash 3.6 for Identifying Neonates With a 5-Minute Apgar Score Less Than 7
時間枠:5 minutes after birth
Sensitivity is defined as the percentage of neonates with a confirmed 5-minute Apgar score less than 7 who are correctly identified as having a "Pathological" CTG tracing by Gemini Flash 3.6. Intrapartum CTG tracings from the final 60 minutes of labor immediately preceding delivery are interpreted according to the 2015 FIGO guidelines. For binary diagnostic performance analysis, a "Pathological" CTG represents a positive test result, while "Normal" and "Suspicious" CTGs represent negative test results. Sensitivity is calculated as [True Positives / (True Positives + False Negatives)] * 100 and reported with a 95% confidence interval.
5 minutes after birth

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年10月1日

一次修了 (推定)

2027年10月1日

研究の完了 (推定)

2027年11月1日

試験登録日

最初に提出

2026年9月14日

QC基準を満たした最初の提出物

2026年9月14日

最初の投稿 (実際)

2026年9月18日

学習記録の更新

投稿された最後の更新 (実際)

2026年9月18日

QC基準を満たした最後の更新が送信されました

2026年9月14日

最終確認日

2026年9月1日

詳しくは

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する