Gemini Flash 3.6 Versus Human Observers for FIGO-Based Interpretation of Intrapartum Cardiotocography
Gemini Flash 3.6 Versus Human Observers for FIGO-Based Interpretation of Intrapartum Cardiotocography: A Diagnostic Accuracy Study
Cardiotocography (CTG) is the standard method for monitoring fetal heart rate and uterine contractions during labor to detect signs of fetal hypoxia. However, human CTG interpretation is often subjective and subject to high interobserver variability, even among experienced clinicians. Multimodal artificial intelligence (AI) models have emerged as potential diagnostic aids capable of evaluating CTG tracings. This prospective diagnostic accuracy study aims to evaluate the diagnostic performance of Gemini Flash 3.6 in interpreting intrapartum CTG recordings according to the 2015 International Federation of Gynecology and Obstetrics (FIGO) guidelines, and to compare its accuracy directly against independent human expert obstetricians.
Participants include pregnant women admitted in active labor at term with a singleton cephalic pregnancy undergoing continuous CTG monitoring. De-identified digital images of the final 60 minutes of CTG tracing prior to delivery will be independently evaluated by Gemini Flash 3.6 and three expert obstetricians. Each evaluator will classify the tracings into one of three FIGO categories: Normal, Suspicious, or Pathological. All evaluators will be blinded to clinical details, delivery outcomes, and other observers' interpretations.
The primary objective is to assess the diagnostic sensitivity of Gemini Flash 3.6 in identifying neonates with a 5-minute Apgar score less than 7. Secondary objectives include comparing the diagnostic performance of the AI model with that of individual expert obstetricians, measuring interobserver agreement among all raters, and assessing associations with 1-minute Apgar scores and umbilical artery blood gas parameters. The AI model will be used solely as an investigational research tool, and its evaluations will not be available to the clinical team or used to guide patient care.
Tutkimuksen yleiskatsaus
Tila
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
- Vanhempi Aikuinen
Hyväksyy terveitä vapaaehtoisia
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
- Singleton pregnancy
- Gestational age 37+0 weeks or greater
- Cephalic fetal presentation
- Admission to the labor ward in active labor
- Continuous intrapartum cardiotocography (CTG) monitoring
- Availability of an interpretable CTG tracing immediately preceding delivery
- Availability of documented 1-minute and 5-minute Apgar scores
- Written informed consent obtained prior to enrollment
Exclusion Criteria:
- Multiple pregnancy
- Major fetal congenital anomalies
- Antepartum stillbirth
- Elective cesarean delivery performed before the onset of labor without an adequate intrapartum CTG tracing
- CTG tracing with inadequate technical quality, including signal loss of 15% or greater
- Missing 5-minute Apgar score
- Technical problems preventing standardized CTG image preparation or interpretation
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Kohortit ja interventiot
Ryhmä/Kohortti |
|---|
|
Intrapartum CTG Monitoring Cohort
Women with singleton term pregnancies (gestational age ≥ 37 + 0 weeks) in cephalic presentation admitted to the labor ward in active labor who undergo routine continuous intrapartum cardiotocography (CTG) monitoring immediately preceding delivery.
De-identified digital CTG tracings from this cohort are independently evaluated by Gemini Flash 3.6 and three expert obstetricians according to the 2015 FIGO consensus guidelines, and validated against neonatal outcomes including 1-minute and 5-minute Apgar scores as well as umbilical artery blood-gas analysis where available.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Sensitivity of Gemini Flash 3.6 for Identifying Neonates With a 5-Minute Apgar Score Less Than 7
Aikaikkuna: 5 minutes after birth
|
Sensitivity is defined as the percentage of neonates with a confirmed 5-minute Apgar score less than 7 who are correctly identified as having a "Pathological" CTG tracing by Gemini Flash 3.6.
Intrapartum CTG tracings from the final 60 minutes of labor immediately preceding delivery are interpreted according to the 2015 FIGO guidelines.
For binary diagnostic performance analysis, a "Pathological" CTG represents a positive test result, while "Normal" and "Suspicious" CTGs represent negative test results.
Sensitivity is calculated as [True Positives / (True Positives + False Negatives)] * 100 and reported with a 95% confidence interval.
|
5 minutes after birth
|
Yhteistyökumppanit ja tutkijat
Sponsori
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Arvioitu)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
- Urogenitaaliset sairaudet
- Naisten virtsa- ja sukupuolielinten sairaudet ja raskauden komplikaatiot
- Raskauden komplikaatiot
- Sikiön sairaudet
- Merkit ja oireet, Hengityselimet
- Hypoksia
- Synnynnäiset, perinnölliset ja vastasyntyneiden sairaudet ja poikkeavuudet
- Patologiset tilat, merkit ja oireet
- Merkit ja oireet
- Sikiön ahdistus
- Sikiön hypoksia
Muut tutkimustunnusnumerot
- Gemini Flash vs Human FIGO CTG
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .