- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT01164319
"UNMASKING Study" For Atrial Fibrillation Recurrences Typing in Early Postoperative Period
Typing of the Atrial Fibrillation Recurrences in Early Postoperative Period After Pulmonary Veins Isolation Through Continous Subcutaneous Monitoring.
연구 개요
연구 유형
등록 (실제)
단계
- 3단계
연락처 및 위치
연구 장소
-
-
-
Novosibirsk, 러시아 연방, 630055
- State Research Institute of Circulation Pathology
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- highly symptomatic patients refractory to at least two antiarrhythmic drugs
- patients with sustained PAF episodes and/or history of PersAF interrupted with cardioversion.
Exclusion Criteria:
- congestive heart failure
- ejection fraction <35%
- left atrial diameter >60 mm
- previous ablation procedure
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 하나의
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
활성 비교기: Group 1 (no early recurrence)
Patients without atrial fibrillation recurrences through the implantable cardiac monitors during the 3 months post-ablation period.
|
The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity. The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
|
활성 비교기: Group 2 (early AF recurrence)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period.
|
The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity. The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
|
활성 비교기: Group 3 (early recurrence-no reablation)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period from Group 2 would not receive reablation.
|
The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity. The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
|
활성 비교기: Group 4 (early recurrence-early reablation)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period from Group 2 will receive early reablation based on data stored by implanted monitor.
|
The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity. The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
|---|---|
|
Freedom from atrial fibrillation or atrial flutter/tachycardia in Group 4 vs Group 3
기간: 12 months
|
12 months
|
2차 결과 측정
결과 측정 |
기간 |
|---|---|
|
Freedom from AF in each group and the comparison of any group to each other
기간: 12 months
|
12 months
|
공동 작업자 및 조사자
간행물 및 유용한 링크
연구 기록 날짜
연구 주요 날짜
연구 시작
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (추정)
연구 기록 업데이트
마지막 업데이트 게시됨 (추정)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .