- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT01164319
"UNMASKING Study" For Atrial Fibrillation Recurrences Typing in Early Postoperative Period
Typing of the Atrial Fibrillation Recurrences in Early Postoperative Period After Pulmonary Veins Isolation Through Continous Subcutaneous Monitoring.
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Studietype
Registrering (Faktiske)
Fase
- Fase 3
Kontakter og plasseringer
Studiesteder
-
-
-
Novosibirsk, Den russiske føderasjonen, 630055
- State Research Institute of Circulation Pathology
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- highly symptomatic patients refractory to at least two antiarrhythmic drugs
- patients with sustained PAF episodes and/or history of PersAF interrupted with cardioversion.
Exclusion Criteria:
- congestive heart failure
- ejection fraction <35%
- left atrial diameter >60 mm
- previous ablation procedure
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Behandling
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Enkelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Aktiv komparator: Group 1 (no early recurrence)
Patients without atrial fibrillation recurrences through the implantable cardiac monitors during the 3 months post-ablation period.
|
The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity. The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
|
Aktiv komparator: Group 2 (early AF recurrence)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period.
|
The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity. The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
|
Aktiv komparator: Group 3 (early recurrence-no reablation)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period from Group 2 would not receive reablation.
|
The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity. The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
|
Aktiv komparator: Group 4 (early recurrence-early reablation)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period from Group 2 will receive early reablation based on data stored by implanted monitor.
|
The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity. The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check. |
Hva måler studien?
Primære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Freedom from atrial fibrillation or atrial flutter/tachycardia in Group 4 vs Group 3
Tidsramme: 12 months
|
12 months
|
Sekundære resultatmål
Resultatmål |
Tidsramme |
|---|---|
|
Freedom from AF in each group and the comparison of any group to each other
Tidsramme: 12 months
|
12 months
|
Samarbeidspartnere og etterforskere
Publikasjoner og nyttige lenker
Studierekorddatoer
Studer hoveddatoer
Studiestart
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Anslag)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Anslag)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- AFERAWCLP-022
- RU AF 002 (Annen identifikator: State Research Institute of Circulation Pathology)
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .