"UNMASKING Study" For Atrial Fibrillation Recurrences Typing in Early Postoperative Period

Typing of the Atrial Fibrillation Recurrences in Early Postoperative Period After Pulmonary Veins Isolation Through Continous Subcutaneous Monitoring.

The aim of this study is to identify the most appropriate method for managing patients with AF recurrences after the first ablation procedure, through the diagnostic data stored by a subcutaneous AF monitor.

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Réel)

150

Phase

  • Phase 3

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Novosibirsk, Fédération Russe, 630055
        • State Research Institute of Circulation Pathology

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 70 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • highly symptomatic patients refractory to at least two antiarrhythmic drugs
  • patients with sustained PAF episodes and/or history of PersAF interrupted with cardioversion.

Exclusion Criteria:

  • congestive heart failure
  • ejection fraction <35%
  • left atrial diameter >60 mm
  • previous ablation procedure

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Seul

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Comparateur actif: Group 1 (no early recurrence)
Patients without atrial fibrillation recurrences through the implantable cardiac monitors during the 3 months post-ablation period.

The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity.

The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.

Comparateur actif: Group 2 (early AF recurrence)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period.

The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity.

The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.

Comparateur actif: Group 3 (early recurrence-no reablation)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period from Group 2 would not receive reablation.

The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity.

The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.

Comparateur actif: Group 4 (early recurrence-early reablation)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period from Group 2 will receive early reablation based on data stored by implanted monitor.

The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity.

The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Délai
Freedom from atrial fibrillation or atrial flutter/tachycardia in Group 4 vs Group 3
Délai: 12 months
12 months

Mesures de résultats secondaires

Mesure des résultats
Délai
Freedom from AF in each group and the comparison of any group to each other
Délai: 12 months
12 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 février 2008

Achèvement primaire (Réel)

1 février 2010

Achèvement de l'étude (Réel)

1 novembre 2010

Dates d'inscription aux études

Première soumission

15 juillet 2010

Première soumission répondant aux critères de contrôle qualité

15 juillet 2010

Première publication (Estimation)

16 juillet 2010

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

24 avril 2012

Dernière mise à jour soumise répondant aux critères de contrôle qualité

23 avril 2012

Dernière vérification

1 avril 2012

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • AFERAWCLP-022
  • RU AF 002 (Autre identifiant: State Research Institute of Circulation Pathology)

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .