"UNMASKING Study" For Atrial Fibrillation Recurrences Typing in Early Postoperative Period

Typing of the Atrial Fibrillation Recurrences in Early Postoperative Period After Pulmonary Veins Isolation Through Continous Subcutaneous Monitoring.

The aim of this study is to identify the most appropriate method for managing patients with AF recurrences after the first ablation procedure, through the diagnostic data stored by a subcutaneous AF monitor.

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Real)

150

Estágio

  • Fase 3

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Novosibirsk, Federação Russa, 630055
        • State Research Institute of Circulation Pathology

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos a 70 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • highly symptomatic patients refractory to at least two antiarrhythmic drugs
  • patients with sustained PAF episodes and/or history of PersAF interrupted with cardioversion.

Exclusion Criteria:

  • congestive heart failure
  • ejection fraction <35%
  • left atrial diameter >60 mm
  • previous ablation procedure

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: Group 1 (no early recurrence)
Patients without atrial fibrillation recurrences through the implantable cardiac monitors during the 3 months post-ablation period.

The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity.

The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.

Comparador Ativo: Group 2 (early AF recurrence)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period.

The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity.

The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.

Comparador Ativo: Group 3 (early recurrence-no reablation)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period from Group 2 would not receive reablation.

The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity.

The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.

Comparador Ativo: Group 4 (early recurrence-early reablation)
Patients with AF recurrences documented by the ICM during the 3 months post-ablation period from Group 2 will receive early reablation based on data stored by implanted monitor.

The left atrium (LA) and PVs were explored through a transeptal approach. Real-time 3D LA maps were reconstructed by using a nonfluoroscopic navigation system (CARTO, Biosense-Webster Inc.). The ipsilateral left and right PVs were encircled in one lesion line by circumferential PV isolation. Radiofrequency energy was delivered at 43°C, 35 W, 0.5 cm away from the PV ostia at the anterior wall, and was reduced to 43°C, 30 W, 1 cm away from the PV ostia at the posterior wall, with a saline irrigation speed of 17 mL/min. The endpoint of ablation was PV isolation; this was confirmed when Lasso mapping showed the disappearance of all PV potentials or the dissociation of PV potentials from LA activity.

The ICM (Reveal XT, Medtronic Inc) was implanted the day of the ablation procedure or 1 week before.The Reveal XT was implanted in the parasternal area of the chest. The requirement for defining the exact final position was an R-wave amplitude ≥0.4 mV assessed through the Vector Check.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Prazo
Freedom from atrial fibrillation or atrial flutter/tachycardia in Group 4 vs Group 3
Prazo: 12 months
12 months

Medidas de resultados secundários

Medida de resultado
Prazo
Freedom from AF in each group and the comparison of any group to each other
Prazo: 12 months
12 months

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo

1 de fevereiro de 2008

Conclusão Primária (Real)

1 de fevereiro de 2010

Conclusão do estudo (Real)

1 de novembro de 2010

Datas de inscrição no estudo

Enviado pela primeira vez

15 de julho de 2010

Enviado pela primeira vez que atendeu aos critérios de CQ

15 de julho de 2010

Primeira postagem (Estimativa)

16 de julho de 2010

Atualizações de registro de estudo

Última Atualização Postada (Estimativa)

24 de abril de 2012

Última atualização enviada que atendeu aos critérios de controle de qualidade

23 de abril de 2012

Última verificação

1 de abril de 2012

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • AFERAWCLP-022
  • RU AF 002 (Outro identificador: State Research Institute of Circulation Pathology)

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever