Comparing Validity of Non-Invasive Hemoglobin Monitoring to Laboratory Results in Critically Ill Children
Verifying the Accuracy of the Masimo Pronto Non-Invasive Hemoglobin (Hb) Monitor and Associated Rainbow Probes Compared to Measured Laboratory Values in Critically Ill Pediatric Patients
연구 개요
상태
상세 설명
This is a prospective study to determine the accuracy of the Masimo Pronto Non-Invasive Hemoglobin Monitor and associated Rainbow® probes in the detection of hemoglobin concentration in critically ill children. Data from at least 30 patients admitted to the Pediatric Intensive Care Unit (PICU) over a period of 2 months will be collected and analyzed for this study.
Note, that this device would not lead to deviations in routine patient care; specifically, the non-invasive monitor placed on the patient's finger is FDA approved. The proposed monitors are identical macroscopically to monitors, which are currently used to measure oxygen saturation at this institution. Clinical decisions, additional blood draws or alterations to the plan of care will not be made based on study data. The objective is to compare the validity of the hemoglobin values determined from non-invasive technology with measured laboratory values for hemoglobin utilized as standard of care.
연구 유형
등록 (실제)
연락처 및 위치
연구 장소
-
-
North Carolina
-
Chapel Hill, North Carolina, 미국, 27599
- Pediatric Intensive Care Unit, University of North Carolina
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Patient has been admitted to Pediatric Intensive Care Unit
- Patient age is ≥ 30 days old and ≤ 18 years old
- Patient weight ≥ 3 Kg.
- Patient requires hemoglobin monitoring
Exclusion Criteria:
- Patient does not have exposed fingers/toes,due to congenital anomalies wound dressing or injury.
- Patient weight is less than 3 Kg
- Patient is less than 30 days old
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 관찰 모델: 보병대
- 시간 관점: 유망한
코호트 및 개입
그룹/코호트 |
개입 / 치료 |
|---|---|
|
Arm A
Critically ill pediatric patients admitted to PICU requiring hemoglobin monitoring. Patients admitted to PICU requiring hemoglobin monitoring will have a reading total hemoglobin (SpHb) assessment done with the Masimo Pronto Rad 7 Non-Invasive hemoglobin monitor,prior to standard laboratory blood draw and hemoglobin analysis. |
Patients admitted to PICU requiring hemoglobin monitoring will have a total hemoglobin (SpHb) assessment from Masimo non-invasive monitor, prior to standard, required blood draw and laboratory analysis.
다른 이름들:
Patients admitted to PICU requiring hemoglobin monitoring will have a reading from Masimo non-invasive monitor, prior to standard, required blood draw and laboratory analysis.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Comparison of standard hemoglobin monitoring vs. the MASIO non-invasive hemoglobin monitor
기간: up to 48 hours, post PICU admission
|
We will obtain measurements using the Masimo Pronto device prior to the standard lab draw at the following time points: post admission to PICU, 12-48 hours. We will then perform analysis using Bland Altman methods to determine the degree of agreement. Data analysis will occur 1 year after enrollment completion. |
up to 48 hours, post PICU admission
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Michael Phillips, MD, University of North Carolina,Chapel Hill, NC
연구 기록 날짜
연구 주요 날짜
연구 시작
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (추정)
연구 기록 업데이트
마지막 업데이트 게시됨 (추정)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- 12-2019
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .