이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Ultrasound-assisted Thoracic Epidural Catheter Insertion

2020년 1월 14일 업데이트: Jong Hyuk Lee, Asan Medical Center

Evaluation of the Accuracy of Real-time Ultrasound-assisted Thoracic Epidural Catheter Insertion: a Pilot Study

The aim of the present study is to access the success rate of ultrasound-guided thoracic epidural catheter insertion, using fluoroscopy.

연구 개요

상세 설명

Thoracic epidural anesthesia has been associated with reduced acute postoperative pain for a wide variety of surgical procedures. It has also been associated with reductions in perioperative cardiac stress, chronic post-thoracotomy pain, and improvements in postoperative pulmonary function. Although a variety of methods can be used to confirm the position of the epidural needle in the epidural space, a blind technique and fluoroscopic guided approach are a widely used method. A thoracic epidural block is a relatively more difficult procedure than procedures used in other regions, because the spinous process of the thoracic vertebra is longer than that of the lumbar vertebra, and the area through which the needle can approach the epidural space is relatively smaller due to an acute angle and larger distance between the skin and the epidural space. Therefore, the success rate of thoracic epidural intervention is only about 68% under a blind technique due to inadequate position of the needle tip, misplacement, occlusion, and migration of the catheter.

Although fluoroscopic guided thoracic epidural intervention is the safest and most accurate method to identify the correct anatomical structures and confirm the epidural space with contrast medium, its use is limited because of the difficulty of using fluoroscope and the burden of radiation exposure. As the use of ultrasound has become popularized and universal, it has been widely used in regional anesthesia and analgesia, has continuously replaced the modality such as a blind technique and fluoroscopic guidance. Ultrasound-guided thoracic epidural catheter insertion was also recently investigated, and then it was conducted successfully in 15 cases of thoracic and upper abdominal surgery. Moreover, it showed several advantages including lowering the number of needle passes and increasing the success rate. However, it has not yet been studied how accurately the catheter is located in the thoracic epidural space during thoracic epidural catheter insertion using real-time ultrasound. Although it is possible to speculate the success of the thoracic epidural catheterization clinically, the identification of the location of the catheter is only possible under fluoroscopic guidance. Therefore, in the present study, we aimed to confirm the success rate of ultrasound-guided thoracic epidural catheter insertion, using fluoroscopy with contrast medium.

연구 유형

중재적

등록 (실제)

38

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

      • Seoul, 대한민국, 05505
        • Asan Medical Center

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

20년 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Patients who will undergo upper abdomen or thoracic surgery
  • Scheduled for thoracic epidural catheter insertion
  • 20 ≤ age <80
  • When obtaining informed consent voluntarily

Exclusion Criteria:

  • Allergy to local anesthetics and contrast dye, and steroid
  • Use of anticoagulants or antiplatelet medication, coagulopathy
  • Infection at the insertion site
  • Neurological or psychiatric disorders
  • Prior spine instrumentation
  • Pregnancy

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 특수 증상
  • 할당: 해당 없음
  • 중재 모델: 단일 그룹 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: Ultrasound-guided TECI
After assessment of the epidural space using the loss of resistance technique with saline under ultrasound guidance, fluoroscopic views will be obtained to confirm which the catheter tip is located in the epidural space or not.
When performing an ultrasound-guided thoracic epidural catheter insertion (TECI), an 18-gauge Tuohy needle will be used for interlaminar epidural access. All procedures will be performed with a paramedian approach under ultrasound-guidance and using the loss of resistance technique with saline. If the needle is deemed to be in the epidural space when the loss of resistance occurred, fluoroscopic views will be obtained to confirm which the catheter tip is located in the epidural space or not.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Success rate of ultrasound-guided thoracic epidural catheter insertion
기간: on the day of the procedure
Confirmation success of ultrasound-guided thoracic epidural catheter insertion using fluoroscopic images; success means that the catheter tip is located in the epidural space.
on the day of the procedure

2차 결과 측정

결과 측정
측정값 설명
기간
Number of skin punctures
기간: on the day of the procedure
complete needle withdrawal from the skin and reinsertion at a new location
on the day of the procedure
Number of needle passes
기간: on the day of the procedure
First needle pass + additional needle passes (the needle returned to a plane perpendicular to the skin before reinsertion. Needle tip maneuvers toward the midline and cephalad were considered standard needle walking technique and were counted as a single pass)
on the day of the procedure
First attempt success rate
기간: on the day of the procedure
only first needle pass and first skin puncture
on the day of the procedure

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Jong-Hyuk Lee, MD, Asan Medical Center

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2019년 7월 4일

기본 완료 (실제)

2019년 12월 12일

연구 완료 (실제)

2019년 12월 20일

연구 등록 날짜

최초 제출

2019년 3월 25일

QC 기준을 충족하는 최초 제출

2019년 3월 25일

처음 게시됨 (실제)

2019년 3월 26일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2020년 1월 18일

QC 기준을 충족하는 마지막 업데이트 제출

2020년 1월 14일

마지막으로 확인됨

2020년 1월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • 2019-0320

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다