Ultrasound-assisted Thoracic Epidural Catheter Insertion

14 января 2020 г. обновлено: Jong Hyuk Lee, Asan Medical Center

Evaluation of the Accuracy of Real-time Ultrasound-assisted Thoracic Epidural Catheter Insertion: a Pilot Study

The aim of the present study is to access the success rate of ultrasound-guided thoracic epidural catheter insertion, using fluoroscopy.

Обзор исследования

Подробное описание

Thoracic epidural anesthesia has been associated with reduced acute postoperative pain for a wide variety of surgical procedures. It has also been associated with reductions in perioperative cardiac stress, chronic post-thoracotomy pain, and improvements in postoperative pulmonary function. Although a variety of methods can be used to confirm the position of the epidural needle in the epidural space, a blind technique and fluoroscopic guided approach are a widely used method. A thoracic epidural block is a relatively more difficult procedure than procedures used in other regions, because the spinous process of the thoracic vertebra is longer than that of the lumbar vertebra, and the area through which the needle can approach the epidural space is relatively smaller due to an acute angle and larger distance between the skin and the epidural space. Therefore, the success rate of thoracic epidural intervention is only about 68% under a blind technique due to inadequate position of the needle tip, misplacement, occlusion, and migration of the catheter.

Although fluoroscopic guided thoracic epidural intervention is the safest and most accurate method to identify the correct anatomical structures and confirm the epidural space with contrast medium, its use is limited because of the difficulty of using fluoroscope and the burden of radiation exposure. As the use of ultrasound has become popularized and universal, it has been widely used in regional anesthesia and analgesia, has continuously replaced the modality such as a blind technique and fluoroscopic guidance. Ultrasound-guided thoracic epidural catheter insertion was also recently investigated, and then it was conducted successfully in 15 cases of thoracic and upper abdominal surgery. Moreover, it showed several advantages including lowering the number of needle passes and increasing the success rate. However, it has not yet been studied how accurately the catheter is located in the thoracic epidural space during thoracic epidural catheter insertion using real-time ultrasound. Although it is possible to speculate the success of the thoracic epidural catheterization clinically, the identification of the location of the catheter is only possible under fluoroscopic guidance. Therefore, in the present study, we aimed to confirm the success rate of ultrasound-guided thoracic epidural catheter insertion, using fluoroscopy with contrast medium.

Тип исследования

Интервенционный

Регистрация (Действительный)

38

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

От 20 лет до 79 лет (Взрослый, Пожилой взрослый)

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

  • Patients who will undergo upper abdomen or thoracic surgery
  • Scheduled for thoracic epidural catheter insertion
  • 20 ≤ age <80
  • When obtaining informed consent voluntarily

Exclusion Criteria:

  • Allergy to local anesthetics and contrast dye, and steroid
  • Use of anticoagulants or antiplatelet medication, coagulopathy
  • Infection at the insertion site
  • Neurological or psychiatric disorders
  • Prior spine instrumentation
  • Pregnancy

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Диагностика
  • Распределение: Н/Д
  • Интервенционная модель: Одногрупповое задание
  • Маскировка: Нет (открытая этикетка)

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: Ultrasound-guided TECI
After assessment of the epidural space using the loss of resistance technique with saline under ultrasound guidance, fluoroscopic views will be obtained to confirm which the catheter tip is located in the epidural space or not.
When performing an ultrasound-guided thoracic epidural catheter insertion (TECI), an 18-gauge Tuohy needle will be used for interlaminar epidural access. All procedures will be performed with a paramedian approach under ultrasound-guidance and using the loss of resistance technique with saline. If the needle is deemed to be in the epidural space when the loss of resistance occurred, fluoroscopic views will be obtained to confirm which the catheter tip is located in the epidural space or not.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Success rate of ultrasound-guided thoracic epidural catheter insertion
Временное ограничение: on the day of the procedure
Confirmation success of ultrasound-guided thoracic epidural catheter insertion using fluoroscopic images; success means that the catheter tip is located in the epidural space.
on the day of the procedure

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Number of skin punctures
Временное ограничение: on the day of the procedure
complete needle withdrawal from the skin and reinsertion at a new location
on the day of the procedure
Number of needle passes
Временное ограничение: on the day of the procedure
First needle pass + additional needle passes (the needle returned to a plane perpendicular to the skin before reinsertion. Needle tip maneuvers toward the midline and cephalad were considered standard needle walking technique and were counted as a single pass)
on the day of the procedure
First attempt success rate
Временное ограничение: on the day of the procedure
only first needle pass and first skin puncture
on the day of the procedure

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Следователи

  • Главный следователь: Jong-Hyuk Lee, MD, Asan Medical Center

Публикации и полезные ссылки

Лицо, ответственное за внесение сведений об исследовании, добровольно предоставляет эти публикации. Это может быть что угодно, связанное с исследованием.

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

4 июля 2019 г.

Первичное завершение (Действительный)

12 декабря 2019 г.

Завершение исследования (Действительный)

20 декабря 2019 г.

Даты регистрации исследования

Первый отправленный

25 марта 2019 г.

Впервые представлено, что соответствует критериям контроля качества

25 марта 2019 г.

Первый опубликованный (Действительный)

26 марта 2019 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

18 января 2020 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

14 января 2020 г.

Последняя проверка

1 января 2020 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • 2019-0320

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Клинические исследования Ultrasound-guided TECI

Подписаться