Ultrasound-assisted Thoracic Epidural Catheter Insertion
Evaluation of the Accuracy of Real-time Ultrasound-assisted Thoracic Epidural Catheter Insertion: a Pilot Study
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Thoracic epidural anesthesia has been associated with reduced acute postoperative pain for a wide variety of surgical procedures. It has also been associated with reductions in perioperative cardiac stress, chronic post-thoracotomy pain, and improvements in postoperative pulmonary function. Although a variety of methods can be used to confirm the position of the epidural needle in the epidural space, a blind technique and fluoroscopic guided approach are a widely used method. A thoracic epidural block is a relatively more difficult procedure than procedures used in other regions, because the spinous process of the thoracic vertebra is longer than that of the lumbar vertebra, and the area through which the needle can approach the epidural space is relatively smaller due to an acute angle and larger distance between the skin and the epidural space. Therefore, the success rate of thoracic epidural intervention is only about 68% under a blind technique due to inadequate position of the needle tip, misplacement, occlusion, and migration of the catheter.
Although fluoroscopic guided thoracic epidural intervention is the safest and most accurate method to identify the correct anatomical structures and confirm the epidural space with contrast medium, its use is limited because of the difficulty of using fluoroscope and the burden of radiation exposure. As the use of ultrasound has become popularized and universal, it has been widely used in regional anesthesia and analgesia, has continuously replaced the modality such as a blind technique and fluoroscopic guidance. Ultrasound-guided thoracic epidural catheter insertion was also recently investigated, and then it was conducted successfully in 15 cases of thoracic and upper abdominal surgery. Moreover, it showed several advantages including lowering the number of needle passes and increasing the success rate. However, it has not yet been studied how accurately the catheter is located in the thoracic epidural space during thoracic epidural catheter insertion using real-time ultrasound. Although it is possible to speculate the success of the thoracic epidural catheterization clinically, the identification of the location of the catheter is only possible under fluoroscopic guidance. Therefore, in the present study, we aimed to confirm the success rate of ultrasound-guided thoracic epidural catheter insertion, using fluoroscopy with contrast medium.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Seoul, Republica da Coréia, 05505
- Asan Medical Center
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Patients who will undergo upper abdomen or thoracic surgery
- Scheduled for thoracic epidural catheter insertion
- 20 ≤ age <80
- When obtaining informed consent voluntarily
Exclusion Criteria:
- Allergy to local anesthetics and contrast dye, and steroid
- Use of anticoagulants or antiplatelet medication, coagulopathy
- Infection at the insertion site
- Neurological or psychiatric disorders
- Prior spine instrumentation
- Pregnancy
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Diagnóstico
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Ultrasound-guided TECI
After assessment of the epidural space using the loss of resistance technique with saline under ultrasound guidance, fluoroscopic views will be obtained to confirm which the catheter tip is located in the epidural space or not.
|
When performing an ultrasound-guided thoracic epidural catheter insertion (TECI), an 18-gauge Tuohy needle will be used for interlaminar epidural access.
All procedures will be performed with a paramedian approach under ultrasound-guidance and using the loss of resistance technique with saline.
If the needle is deemed to be in the epidural space when the loss of resistance occurred, fluoroscopic views will be obtained to confirm which the catheter tip is located in the epidural space or not.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Success rate of ultrasound-guided thoracic epidural catheter insertion
Prazo: on the day of the procedure
|
Confirmation success of ultrasound-guided thoracic epidural catheter insertion using fluoroscopic images; success means that the catheter tip is located in the epidural space.
|
on the day of the procedure
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Number of skin punctures
Prazo: on the day of the procedure
|
complete needle withdrawal from the skin and reinsertion at a new location
|
on the day of the procedure
|
|
Number of needle passes
Prazo: on the day of the procedure
|
First needle pass + additional needle passes (the needle returned to a plane perpendicular to the skin before reinsertion.
Needle tip maneuvers toward the midline and cephalad were considered standard needle walking technique and were counted as a single pass)
|
on the day of the procedure
|
|
First attempt success rate
Prazo: on the day of the procedure
|
only first needle pass and first skin puncture
|
on the day of the procedure
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Jong-Hyuk Lee, MD, Asan Medical Center
Publicações e links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 2019-0320
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .