Ultrasound-assisted Thoracic Epidural Catheter Insertion
Evaluation of the Accuracy of Real-time Ultrasound-assisted Thoracic Epidural Catheter Insertion: a Pilot Study
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
Thoracic epidural anesthesia has been associated with reduced acute postoperative pain for a wide variety of surgical procedures. It has also been associated with reductions in perioperative cardiac stress, chronic post-thoracotomy pain, and improvements in postoperative pulmonary function. Although a variety of methods can be used to confirm the position of the epidural needle in the epidural space, a blind technique and fluoroscopic guided approach are a widely used method. A thoracic epidural block is a relatively more difficult procedure than procedures used in other regions, because the spinous process of the thoracic vertebra is longer than that of the lumbar vertebra, and the area through which the needle can approach the epidural space is relatively smaller due to an acute angle and larger distance between the skin and the epidural space. Therefore, the success rate of thoracic epidural intervention is only about 68% under a blind technique due to inadequate position of the needle tip, misplacement, occlusion, and migration of the catheter.
Although fluoroscopic guided thoracic epidural intervention is the safest and most accurate method to identify the correct anatomical structures and confirm the epidural space with contrast medium, its use is limited because of the difficulty of using fluoroscope and the burden of radiation exposure. As the use of ultrasound has become popularized and universal, it has been widely used in regional anesthesia and analgesia, has continuously replaced the modality such as a blind technique and fluoroscopic guidance. Ultrasound-guided thoracic epidural catheter insertion was also recently investigated, and then it was conducted successfully in 15 cases of thoracic and upper abdominal surgery. Moreover, it showed several advantages including lowering the number of needle passes and increasing the success rate. However, it has not yet been studied how accurately the catheter is located in the thoracic epidural space during thoracic epidural catheter insertion using real-time ultrasound. Although it is possible to speculate the success of the thoracic epidural catheterization clinically, the identification of the location of the catheter is only possible under fluoroscopic guidance. Therefore, in the present study, we aimed to confirm the success rate of ultrasound-guided thoracic epidural catheter insertion, using fluoroscopy with contrast medium.
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Seoul, Korea, republiek van, 05505
- Asan Medical Center
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Patients who will undergo upper abdomen or thoracic surgery
- Scheduled for thoracic epidural catheter insertion
- 20 ≤ age <80
- When obtaining informed consent voluntarily
Exclusion Criteria:
- Allergy to local anesthetics and contrast dye, and steroid
- Use of anticoagulants or antiplatelet medication, coagulopathy
- Infection at the insertion site
- Neurological or psychiatric disorders
- Prior spine instrumentation
- Pregnancy
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Diagnostisch
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Ultrasound-guided TECI
After assessment of the epidural space using the loss of resistance technique with saline under ultrasound guidance, fluoroscopic views will be obtained to confirm which the catheter tip is located in the epidural space or not.
|
When performing an ultrasound-guided thoracic epidural catheter insertion (TECI), an 18-gauge Tuohy needle will be used for interlaminar epidural access.
All procedures will be performed with a paramedian approach under ultrasound-guidance and using the loss of resistance technique with saline.
If the needle is deemed to be in the epidural space when the loss of resistance occurred, fluoroscopic views will be obtained to confirm which the catheter tip is located in the epidural space or not.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Success rate of ultrasound-guided thoracic epidural catheter insertion
Tijdsspanne: on the day of the procedure
|
Confirmation success of ultrasound-guided thoracic epidural catheter insertion using fluoroscopic images; success means that the catheter tip is located in the epidural space.
|
on the day of the procedure
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Number of skin punctures
Tijdsspanne: on the day of the procedure
|
complete needle withdrawal from the skin and reinsertion at a new location
|
on the day of the procedure
|
|
Number of needle passes
Tijdsspanne: on the day of the procedure
|
First needle pass + additional needle passes (the needle returned to a plane perpendicular to the skin before reinsertion.
Needle tip maneuvers toward the midline and cephalad were considered standard needle walking technique and were counted as a single pass)
|
on the day of the procedure
|
|
First attempt success rate
Tijdsspanne: on the day of the procedure
|
only first needle pass and first skin puncture
|
on the day of the procedure
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Jong-Hyuk Lee, MD, Asan Medical Center
Publicaties en nuttige links
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 2019-0320
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .