이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Effect of Aging and Aerobic Fitness Level on Heat Dissipation

2020년 1월 22일 업데이트: Petros Dinas

Effect of Aging and Aerobic Fitness Level on Heat Dissipation in Neutral Conditions

In the context of global aging, the health risk factors associated with exercising or working in the heat for aging population are exacerbated by the rising in global surface temperatures. The purpose of this investigation is to determine at what age the heat loss decrements occur and to examine if aerobic fitness level can affect the heat loss capacity in neutral environmental conditions.

연구 개요

상태

완전한

상세 설명

All trials were conducted to indoor gyms with the same environmental temperature and relative humidity, 26 - 30oC and 40-50% respectively, to ensure no difference in body temperature were due to the external thermal stress. The participants were instructed to refrain from intense exercise as well as alcohol and caffeine consumption for 24 hours prior to experimental trial and to had a light meal 2h before their arrival.

Upon arrival, participants would have to wear running shoes, light and short running shorts and light cotton socks. Participants received comprehensive instructions about the shuttle run test and the whole process of measurements. Firstly participants answered the International Physical Activity Questionnaire (IPAQ). Thereafter, anthropometrics data (weight and height) were evaluated as well as the body temperature in external ear canal and axillary. All participants followed five minutes warming up and then performed to 20 m shuttle run test until their volitional limit. Once the participants could no longer run, the test was over and the number of laps was recorded. After the end of the shuttle run, were evaluated the body temperature and the weight of each participants. No fluids consumptions were permitted until the second weighing. They were weighed twice, at baseline and at the end of the running test with a precision weight scale (Kern DE 150K2D, KERN & SOHN GmbH, Balingen, Germany).

Environmental data including air temperature and relative humidity were measured continuously using a portable weather station (LCD Digital Temperature & Humidity Meter HTC-1). The weather station was placed 1 meter above the ground according to the manufacturer's guidelines.

연구 유형

중재적

등록 (실제)

431

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Thessaly
      • Trikala, Thessaly, 그리스, 42100
        • Department of Exercise Science, University of Thessaly
      • Tríkala, Thessaly, 그리스, 42100
        • FAME Lab, Department of Exercise Science, University of Thessaly

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

9년 (어린이, 성인)

건강한 자원 봉사자를 받아들입니다

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Healthy children and adults

Exclusion Criteria:

  • Diagnosed chronic medical condition;
  • Symptoms of acute illness;
  • Recent (past 4 weeks) usage of medications known to affect the circulatory system, the thyroid, the pituitary function, or the metabolic status

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 방지
  • 할당: 해당 없음
  • 중재 모델: 단일 그룹 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: Shuttle run test
At the shuttle run test, participants were required to run between two lines 20 meters apart, while keeping pace with audio signals emitted from a pre-recorded CD. The frequency of the sound signals increases in such way that running speed was increased by 0.5 km h-1 each minute from the starting speed 8.5 km h-1.
At the shuttle run test, participants were required to run between two lines 20 meters apart, while keeping pace with audio signals emitted from a pre-recorded CD. The frequency of the sound signals increases in such way that running speed was increased by 0.5 km h-1 each minute from the starting speed 8.5 km h-1.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Aerobic fitness level
기간: Through study completion (a shuttle run test), an average of 15 minutes
Aerobic fitness level was defined by peak oxygen uptake (VO2peak). VO2peak was determined by a 20m shuttle run test. The number of the last announced stage and the equivalent maximal speed from participants' performance were used for its VO2peak estimation
Through study completion (a shuttle run test), an average of 15 minutes
Change from baseline ear canal temperature
기간: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Ear canal temperature was recorded twice, at baseline and at the end of the shuttle run test (three times each at the left ear and recorded the mean value), using ear thermometer (IR100, MicrolifeSwitzerland)
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Change from baseline axillary temperature
기간: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Axillary temperature was recorded twice, at baseline and at the end of the shuttle run test, using the electronic digital thermometer (EcoTemp, OMRON, Japan)
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Physical activity levels
기간: Once before the shuttle run test
Physical activity of the subject in a usual week was recorded via International Physical Activity Questionnaire. Scores include steps/day and METs/week, with no lower and upper limit
Once before the shuttle run test
Change from baseline body weight
기간: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Weight was recorded twice, at baseline and at the end of the shuttle run test, using a precision weight scale (Kern DE 150K2D, KERN & SOHN GmbH, Balingen, Germany
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Change from baseline whole Body Sweat Rate
기간: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Whole Body Sweat Rate was determined by the difference of the pre-test and post-test weight of the participants
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Air temperature
기간: Up to 30 minutes, during a one complete shuttle run test
Air temperature was measured continuously using a portable weather station (LCD Digital Temperature & Humidity Meter HTC-1placed) 1 meter above the ground according to the manufacturer's guidelines
Up to 30 minutes, during a one complete shuttle run test
Relative humidity
기간: Up to 30 minutes, during a one complete shuttle run test
Relative humidity was measured continuously using a portable weather station (LCD Digital Temperature & Humidity Meter HTC-1) placed 1 meter above the ground according to the manufacturer's guidelines
Up to 30 minutes, during a one complete shuttle run test

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2014년 5월 1일

기본 완료 (실제)

2018년 10월 30일

연구 완료 (실제)

2018년 10월 30일

연구 등록 날짜

최초 제출

2020년 1월 16일

QC 기준을 충족하는 최초 제출

2020년 1월 22일

처음 게시됨 (실제)

2020년 1월 27일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2020년 1월 27일

QC 기준을 충족하는 마지막 업데이트 제출

2020년 1월 22일

마지막으로 확인됨

2020년 1월 1일

추가 정보

이 연구와 관련된 용어

추가 관련 MeSH 약관

기타 연구 ID 번호

  • 10. Aging and heat loss

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

미정

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

Shuttle run test에 대한 임상 시험

구독하다