Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Effect of Aging and Aerobic Fitness Level on Heat Dissipation

22 января 2020 г. обновлено: Petros Dinas

Effect of Aging and Aerobic Fitness Level on Heat Dissipation in Neutral Conditions

In the context of global aging, the health risk factors associated with exercising or working in the heat for aging population are exacerbated by the rising in global surface temperatures. The purpose of this investigation is to determine at what age the heat loss decrements occur and to examine if aerobic fitness level can affect the heat loss capacity in neutral environmental conditions.

Обзор исследования

Статус

Завершенный

Вмешательство/лечение

Подробное описание

All trials were conducted to indoor gyms with the same environmental temperature and relative humidity, 26 - 30oC and 40-50% respectively, to ensure no difference in body temperature were due to the external thermal stress. The participants were instructed to refrain from intense exercise as well as alcohol and caffeine consumption for 24 hours prior to experimental trial and to had a light meal 2h before their arrival.

Upon arrival, participants would have to wear running shoes, light and short running shorts and light cotton socks. Participants received comprehensive instructions about the shuttle run test and the whole process of measurements. Firstly participants answered the International Physical Activity Questionnaire (IPAQ). Thereafter, anthropometrics data (weight and height) were evaluated as well as the body temperature in external ear canal and axillary. All participants followed five minutes warming up and then performed to 20 m shuttle run test until their volitional limit. Once the participants could no longer run, the test was over and the number of laps was recorded. After the end of the shuttle run, were evaluated the body temperature and the weight of each participants. No fluids consumptions were permitted until the second weighing. They were weighed twice, at baseline and at the end of the running test with a precision weight scale (Kern DE 150K2D, KERN & SOHN GmbH, Balingen, Germany).

Environmental data including air temperature and relative humidity were measured continuously using a portable weather station (LCD Digital Temperature & Humidity Meter HTC-1). The weather station was placed 1 meter above the ground according to the manufacturer's guidelines.

Тип исследования

Интервенционный

Регистрация (Действительный)

431

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

    • Thessaly
      • Trikala, Thessaly, Греция, 42100
        • Department of Exercise Science, University of Thessaly
      • Tríkala, Thessaly, Греция, 42100
        • FAME Lab, Department of Exercise Science, University of Thessaly

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

От 9 лет до 60 лет (Ребенок, Взрослый)

Принимает здоровых добровольцев

Да

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

  • Healthy children and adults

Exclusion Criteria:

  • Diagnosed chronic medical condition;
  • Symptoms of acute illness;
  • Recent (past 4 weeks) usage of medications known to affect the circulatory system, the thyroid, the pituitary function, or the metabolic status

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Профилактика
  • Распределение: Н/Д
  • Интервенционная модель: Одногрупповое задание
  • Маскировка: Нет (открытая этикетка)

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: Shuttle run test
At the shuttle run test, participants were required to run between two lines 20 meters apart, while keeping pace with audio signals emitted from a pre-recorded CD. The frequency of the sound signals increases in such way that running speed was increased by 0.5 km h-1 each minute from the starting speed 8.5 km h-1.
At the shuttle run test, participants were required to run between two lines 20 meters apart, while keeping pace with audio signals emitted from a pre-recorded CD. The frequency of the sound signals increases in such way that running speed was increased by 0.5 km h-1 each minute from the starting speed 8.5 km h-1.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Aerobic fitness level
Временное ограничение: Through study completion (a shuttle run test), an average of 15 minutes
Aerobic fitness level was defined by peak oxygen uptake (VO2peak). VO2peak was determined by a 20m shuttle run test. The number of the last announced stage and the equivalent maximal speed from participants' performance were used for its VO2peak estimation
Through study completion (a shuttle run test), an average of 15 minutes
Change from baseline ear canal temperature
Временное ограничение: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Ear canal temperature was recorded twice, at baseline and at the end of the shuttle run test (three times each at the left ear and recorded the mean value), using ear thermometer (IR100, MicrolifeSwitzerland)
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Change from baseline axillary temperature
Временное ограничение: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Axillary temperature was recorded twice, at baseline and at the end of the shuttle run test, using the electronic digital thermometer (EcoTemp, OMRON, Japan)
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Physical activity levels
Временное ограничение: Once before the shuttle run test
Physical activity of the subject in a usual week was recorded via International Physical Activity Questionnaire. Scores include steps/day and METs/week, with no lower and upper limit
Once before the shuttle run test
Change from baseline body weight
Временное ограничение: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Weight was recorded twice, at baseline and at the end of the shuttle run test, using a precision weight scale (Kern DE 150K2D, KERN & SOHN GmbH, Balingen, Germany
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Change from baseline whole Body Sweat Rate
Временное ограничение: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Whole Body Sweat Rate was determined by the difference of the pre-test and post-test weight of the participants
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
Air temperature
Временное ограничение: Up to 30 minutes, during a one complete shuttle run test
Air temperature was measured continuously using a portable weather station (LCD Digital Temperature & Humidity Meter HTC-1placed) 1 meter above the ground according to the manufacturer's guidelines
Up to 30 minutes, during a one complete shuttle run test
Relative humidity
Временное ограничение: Up to 30 minutes, during a one complete shuttle run test
Relative humidity was measured continuously using a portable weather station (LCD Digital Temperature & Humidity Meter HTC-1) placed 1 meter above the ground according to the manufacturer's guidelines
Up to 30 minutes, during a one complete shuttle run test

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

1 мая 2014 г.

Первичное завершение (Действительный)

30 октября 2018 г.

Завершение исследования (Действительный)

30 октября 2018 г.

Даты регистрации исследования

Первый отправленный

16 января 2020 г.

Впервые представлено, что соответствует критериям контроля качества

22 января 2020 г.

Первый опубликованный (Действительный)

27 января 2020 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

27 января 2020 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

22 января 2020 г.

Последняя проверка

1 января 2020 г.

Дополнительная информация

Термины, связанные с этим исследованием

Дополнительные соответствующие термины MeSH

Другие идентификационные номера исследования

  • 10. Aging and heat loss

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕ РЕШЕНО

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться