All trials were conducted to indoor gyms with the same environmental temperature and relative humidity, 26 - 30oC and 40-50% respectively, to ensure no difference in body temperature were due to the external thermal stress. The participants were instructed to refrain from intense exercise as well as alcohol and caffeine consumption for 24 hours prior to experimental trial and to had a light meal 2h before their arrival.
Upon arrival, participants would have to wear running shoes, light and short running shorts and light cotton socks. Participants received comprehensive instructions about the shuttle run test and the whole process of measurements. Firstly participants answered the International Physical Activity Questionnaire (IPAQ). Thereafter, anthropometrics data (weight and height) were evaluated as well as the body temperature in external ear canal and axillary. All participants followed five minutes warming up and then performed to 20 m shuttle run test until their volitional limit. Once the participants could no longer run, the test was over and the number of laps was recorded. After the end of the shuttle run, were evaluated the body temperature and the weight of each participants. No fluids consumptions were permitted until the second weighing. They were weighed twice, at baseline and at the end of the running test with a precision weight scale (Kern DE 150K2D, KERN & SOHN GmbH, Balingen, Germany).
Environmental data including air temperature and relative humidity were measured continuously using a portable weather station (LCD Digital Temperature & Humidity Meter HTC-1). The weather station was placed 1 meter above the ground according to the manufacturer's guidelines.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
Thessaly
-
Trikala, Thessaly, Grécia, 42100
- Department of Exercise Science, University of Thessaly
-
Tríkala, Thessaly, Grécia, 42100
- FAME Lab, Department of Exercise Science, University of Thessaly
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Healthy children and adults
Exclusion Criteria:
- Diagnosed chronic medical condition;
- Symptoms of acute illness;
- Recent (past 4 weeks) usage of medications known to affect the circulatory system, the thyroid, the pituitary function, or the metabolic status
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Prevenção
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Shuttle run test
At the shuttle run test, participants were required to run between two lines 20 meters apart, while keeping pace with audio signals emitted from a pre-recorded CD.
The frequency of the sound signals increases in such way that running speed was increased by 0.5 km h-1 each minute from the starting speed 8.5 km h-1.
|
At the shuttle run test, participants were required to run between two lines 20 meters apart, while keeping pace with audio signals emitted from a pre-recorded CD.
The frequency of the sound signals increases in such way that running speed was increased by 0.5 km h-1 each minute from the starting speed 8.5 km h-1.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Aerobic fitness level
Prazo: Through study completion (a shuttle run test), an average of 15 minutes
|
Aerobic fitness level was defined by peak oxygen uptake (VO2peak).
VO2peak was determined by a 20m shuttle run test.
The number of the last announced stage and the equivalent maximal speed from participants' performance were used for its VO2peak estimation
|
Through study completion (a shuttle run test), an average of 15 minutes
|
|
Change from baseline ear canal temperature
Prazo: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
|
Ear canal temperature was recorded twice, at baseline and at the end of the shuttle run test (three times each at the left ear and recorded the mean value), using ear thermometer (IR100, MicrolifeSwitzerland)
|
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
|
|
Change from baseline axillary temperature
Prazo: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
|
Axillary temperature was recorded twice, at baseline and at the end of the shuttle run test, using the electronic digital thermometer (EcoTemp, OMRON, Japan)
|
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
|
|
Physical activity levels
Prazo: Once before the shuttle run test
|
Physical activity of the subject in a usual week was recorded via International Physical Activity Questionnaire.
Scores include steps/day and METs/week, with no lower and upper limit
|
Once before the shuttle run test
|
|
Change from baseline body weight
Prazo: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
|
Weight was recorded twice, at baseline and at the end of the shuttle run test, using a precision weight scale (Kern DE 150K2D, KERN & SOHN GmbH, Balingen, Germany
|
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
|
|
Change from baseline whole Body Sweat Rate
Prazo: Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
|
Whole Body Sweat Rate was determined by the difference of the pre-test and post-test weight of the participants
|
Change from baseline to the end of study completion (a shuttle run test), an average of 15 minutes
|
|
Air temperature
Prazo: Up to 30 minutes, during a one complete shuttle run test
|
Air temperature was measured continuously using a portable weather station (LCD Digital Temperature & Humidity Meter HTC-1placed) 1 meter above the ground according to the manufacturer's guidelines
|
Up to 30 minutes, during a one complete shuttle run test
|
|
Relative humidity
Prazo: Up to 30 minutes, during a one complete shuttle run test
|
Relative humidity was measured continuously using a portable weather station (LCD Digital Temperature & Humidity Meter HTC-1) placed 1 meter above the ground according to the manufacturer's guidelines
|
Up to 30 minutes, during a one complete shuttle run test
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 10. Aging and heat loss
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .