- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT04243460
Influence of Soft Tissue Thickness on the Bone Level Around Implants
Influence of Soft Tissue Thickness on the Marginal Bone Level Around Implants in Esthetic Zone: 1 Year Randomized Control Trail
연구 개요
상태
정황
상세 설명
Healthy soft tissue around the implant are considered as a biological seal to prevent inflammatory periimplant diseases and ensure healthy, stable and long-term survival of a dental implant. Due to the fact that the measurement methods in the literature differ, it is necessary to establish objective measurement method and to determine the minimum amount of tissue thickness to maintain a stable level of bone around the implant.
Purpose:
The aim of the study was to determine the effect of soft tissues in the implant area on the marginal bone level loss in the implant area and to define of the critical gingival thickness to minimize marginal bone level (MBL) loss.
Materials and methods:
75 bone level implants (Conelog® Camlog, Switzerland) were inserted in the aesthetic area. Thickening of soft tissues was performed both before and after implantation (group II and III), CTG and XCM were used (subgroup a and b). 12 months after the loading with final restoration, the thickness of soft tissues in the implant area was examined with ultrasonography (USG) device (Pirop®, Echoson, Poland), and each implant was subjected to Radiovisiography (RVG) RVG examination, where MBL loss was determined.
연구 유형
등록 (실제)
단계
- 해당 없음
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
To qualify for the study, the patients had to be >18 years and have missing teeth in the esthetic zone. Additional inclusion criteria were as follows:
- missing single or double teeth in the anterior area of their upper or lower jaw with a proper inter arch relationship (incisors, canines and first premolar) with a ridge width (bucco-lingual) greater than 5 mm at its narrowest point and a minimum keratinized gingiva height of 2 mm buccally.
- No previous soft tissue augmentation procedure at experimental site
Exclusion Criteria:
The criteria that disqualified patients from the study were previous grafting procedures in the area of interest and systemic or local diseases that could compromise healing or osteointegration. Smokers and patients with bruxism were also excluded from the study. Additional exclusion criteria were as follows:
- implants placed with an insertion torque of 35 Ncm or less;
- irradiation in the head and neck area;
- untreated periodontitis;
- poor oral hygiene (plaque score Approximal Plaque Index (API) 20%, bleeding score 10%) and
- poor motivation;
- fresh post extraction sockets
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 하나의
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: CTG connective tissue graft augmentation
CTG connective tissue graft (CTG) was used for soft tissue augmentation.
I
|
12 months after gingival augmentation Measurement of marginal bone level and soft tissue thickness were done.
STT (soft tissue thickness) was measured using ultrasonography with a Pirop® dental, ultrasound device (Echoson Company, Poland).
The patients underwent a clinical and ultrasound examination before, 3 and 12 months after gingival augmentation (GA) respectively to evaluate STT (soft tissue thickness) at two points using ultrasound equipment (Pirop®, Echoson).
|
|
활성 비교기: XCM Xenogeneic collagen matrix (XCM)graft augmentation
Xenogeneic collagen matrix (XCM) was used for soft tissue augmentation.
|
12 months after gingival augmentation Measurement of marginal bone level and soft tissue thickness were done. STT (soft tissue thickness) was measured using ultrasonography with a Pirop® dental, ultrasound device (Echoson Company, Poland). The patients underwent a clinical and ultrasound examination before, 3 and 12 months after gingival augmentation (GA) respectively to evaluate TKT at two points using ultrasound equipment (Pirop®, Echoson). Intraoral radiographs were taken using a paralleling technique with a Rinn-type film holder in high resolution mode (Visualixe HD®, Gendex®, USA). Two images of each region were selected to calculate the marginal bone changes: |
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Ultrasound examination
기간: 12 months
|
ultrasound USG examination of tissue hickness
|
12 months
|
|
Radiological examination
기간: 12 monhs
|
RVG examination of marginal bone level change
|
12 monhs
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Jakub Hadzik, PhD, DDS, jakub.hadzik@umed.wroc.pl
간행물 및 유용한 링크
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .