- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT04243460
Influence of Soft Tissue Thickness on the Bone Level Around Implants
Influence of Soft Tissue Thickness on the Marginal Bone Level Around Implants in Esthetic Zone: 1 Year Randomized Control Trail
Studieoversigt
Status
Betingelser
Detaljeret beskrivelse
Healthy soft tissue around the implant are considered as a biological seal to prevent inflammatory periimplant diseases and ensure healthy, stable and long-term survival of a dental implant. Due to the fact that the measurement methods in the literature differ, it is necessary to establish objective measurement method and to determine the minimum amount of tissue thickness to maintain a stable level of bone around the implant.
Purpose:
The aim of the study was to determine the effect of soft tissues in the implant area on the marginal bone level loss in the implant area and to define of the critical gingival thickness to minimize marginal bone level (MBL) loss.
Materials and methods:
75 bone level implants (Conelog® Camlog, Switzerland) were inserted in the aesthetic area. Thickening of soft tissues was performed both before and after implantation (group II and III), CTG and XCM were used (subgroup a and b). 12 months after the loading with final restoration, the thickness of soft tissues in the implant area was examined with ultrasonography (USG) device (Pirop®, Echoson, Poland), and each implant was subjected to Radiovisiography (RVG) RVG examination, where MBL loss was determined.
Undersøgelsestype
Tilmelding (Faktiske)
Fase
- Ikke anvendelig
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
To qualify for the study, the patients had to be >18 years and have missing teeth in the esthetic zone. Additional inclusion criteria were as follows:
- missing single or double teeth in the anterior area of their upper or lower jaw with a proper inter arch relationship (incisors, canines and first premolar) with a ridge width (bucco-lingual) greater than 5 mm at its narrowest point and a minimum keratinized gingiva height of 2 mm buccally.
- No previous soft tissue augmentation procedure at experimental site
Exclusion Criteria:
The criteria that disqualified patients from the study were previous grafting procedures in the area of interest and systemic or local diseases that could compromise healing or osteointegration. Smokers and patients with bruxism were also excluded from the study. Additional exclusion criteria were as follows:
- implants placed with an insertion torque of 35 Ncm or less;
- irradiation in the head and neck area;
- untreated periodontitis;
- poor oral hygiene (plaque score Approximal Plaque Index (API) 20%, bleeding score 10%) and
- poor motivation;
- fresh post extraction sockets
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Behandling
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Enkelt
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Eksperimentel: CTG connective tissue graft augmentation
CTG connective tissue graft (CTG) was used for soft tissue augmentation.
I
|
12 months after gingival augmentation Measurement of marginal bone level and soft tissue thickness were done.
STT (soft tissue thickness) was measured using ultrasonography with a Pirop® dental, ultrasound device (Echoson Company, Poland).
The patients underwent a clinical and ultrasound examination before, 3 and 12 months after gingival augmentation (GA) respectively to evaluate STT (soft tissue thickness) at two points using ultrasound equipment (Pirop®, Echoson).
|
|
Aktiv komparator: XCM Xenogeneic collagen matrix (XCM)graft augmentation
Xenogeneic collagen matrix (XCM) was used for soft tissue augmentation.
|
12 months after gingival augmentation Measurement of marginal bone level and soft tissue thickness were done. STT (soft tissue thickness) was measured using ultrasonography with a Pirop® dental, ultrasound device (Echoson Company, Poland). The patients underwent a clinical and ultrasound examination before, 3 and 12 months after gingival augmentation (GA) respectively to evaluate TKT at two points using ultrasound equipment (Pirop®, Echoson). Intraoral radiographs were taken using a paralleling technique with a Rinn-type film holder in high resolution mode (Visualixe HD®, Gendex®, USA). Two images of each region were selected to calculate the marginal bone changes: |
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Ultrasound examination
Tidsramme: 12 months
|
ultrasound USG examination of tissue hickness
|
12 months
|
|
Radiological examination
Tidsramme: 12 monhs
|
RVG examination of marginal bone level change
|
12 monhs
|
Samarbejdspartnere og efterforskere
Efterforskere
- Ledende efterforsker: Jakub Hadzik, PhD, DDS, jakub.hadzik@umed.wroc.pl
Publikationer og nyttige links
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Faktiske)
Studieafslutning (Faktiske)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- STT and MBL
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
produkt fremstillet i og eksporteret fra U.S.A.
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .