- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT04243460
Influence of Soft Tissue Thickness on the Bone Level Around Implants
Influence of Soft Tissue Thickness on the Marginal Bone Level Around Implants in Esthetic Zone: 1 Year Randomized Control Trail
Tutkimuksen yleiskatsaus
Tila
Ehdot
Yksityiskohtainen kuvaus
Healthy soft tissue around the implant are considered as a biological seal to prevent inflammatory periimplant diseases and ensure healthy, stable and long-term survival of a dental implant. Due to the fact that the measurement methods in the literature differ, it is necessary to establish objective measurement method and to determine the minimum amount of tissue thickness to maintain a stable level of bone around the implant.
Purpose:
The aim of the study was to determine the effect of soft tissues in the implant area on the marginal bone level loss in the implant area and to define of the critical gingival thickness to minimize marginal bone level (MBL) loss.
Materials and methods:
75 bone level implants (Conelog® Camlog, Switzerland) were inserted in the aesthetic area. Thickening of soft tissues was performed both before and after implantation (group II and III), CTG and XCM were used (subgroup a and b). 12 months after the loading with final restoration, the thickness of soft tissues in the implant area was examined with ultrasonography (USG) device (Pirop®, Echoson, Poland), and each implant was subjected to Radiovisiography (RVG) RVG examination, where MBL loss was determined.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Vaihe
- Ei sovellettavissa
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
To qualify for the study, the patients had to be >18 years and have missing teeth in the esthetic zone. Additional inclusion criteria were as follows:
- missing single or double teeth in the anterior area of their upper or lower jaw with a proper inter arch relationship (incisors, canines and first premolar) with a ridge width (bucco-lingual) greater than 5 mm at its narrowest point and a minimum keratinized gingiva height of 2 mm buccally.
- No previous soft tissue augmentation procedure at experimental site
Exclusion Criteria:
The criteria that disqualified patients from the study were previous grafting procedures in the area of interest and systemic or local diseases that could compromise healing or osteointegration. Smokers and patients with bruxism were also excluded from the study. Additional exclusion criteria were as follows:
- implants placed with an insertion torque of 35 Ncm or less;
- irradiation in the head and neck area;
- untreated periodontitis;
- poor oral hygiene (plaque score Approximal Plaque Index (API) 20%, bleeding score 10%) and
- poor motivation;
- fresh post extraction sockets
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Yksittäinen
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: CTG connective tissue graft augmentation
CTG connective tissue graft (CTG) was used for soft tissue augmentation.
I
|
12 months after gingival augmentation Measurement of marginal bone level and soft tissue thickness were done.
STT (soft tissue thickness) was measured using ultrasonography with a Pirop® dental, ultrasound device (Echoson Company, Poland).
The patients underwent a clinical and ultrasound examination before, 3 and 12 months after gingival augmentation (GA) respectively to evaluate STT (soft tissue thickness) at two points using ultrasound equipment (Pirop®, Echoson).
|
|
Active Comparator: XCM Xenogeneic collagen matrix (XCM)graft augmentation
Xenogeneic collagen matrix (XCM) was used for soft tissue augmentation.
|
12 months after gingival augmentation Measurement of marginal bone level and soft tissue thickness were done. STT (soft tissue thickness) was measured using ultrasonography with a Pirop® dental, ultrasound device (Echoson Company, Poland). The patients underwent a clinical and ultrasound examination before, 3 and 12 months after gingival augmentation (GA) respectively to evaluate TKT at two points using ultrasound equipment (Pirop®, Echoson). Intraoral radiographs were taken using a paralleling technique with a Rinn-type film holder in high resolution mode (Visualixe HD®, Gendex®, USA). Two images of each region were selected to calculate the marginal bone changes: |
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Ultrasound examination
Aikaikkuna: 12 months
|
ultrasound USG examination of tissue hickness
|
12 months
|
|
Radiological examination
Aikaikkuna: 12 monhs
|
RVG examination of marginal bone level change
|
12 monhs
|
Yhteistyökumppanit ja tutkijat
Tutkijat
- Päätutkija: Jakub Hadzik, PhD, DDS, jakub.hadzik@umed.wroc.pl
Julkaisuja ja hyödyllisiä linkkejä
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- STT and MBL
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Yhdysvalloissa valmistettu ja sieltä viety tuote
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .