- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07590908
CARA-VT: a Dosimetric in Silico Study (CARA-VT)
Non-invasive CArdiac RAdioablation for Ventricular Tachycardia: a Feasibility Dosimetric in Silico Study Based on a Prospective Cohort of Patients to Compare Photon to Proton and to Carbon Ion Radiotherapy
Ventricular tachycardia (VT) is a potentially deadly condition, common in patients with structural heart disease or dilated cardiomyopathy. VTpatients are currently treated with anti-arrhythmic drugs, implanted cardioverter defibrillators or invasive catheter ablation (CA) but the overall success rate of this techniqueis still suboptimal.
One of the main reasons is an anatomically inaccessible location of VT's origin (within the mid-wall of the myocardium, on the epicardial site or adjacent to critical structures). Moreover, repeated invasive ablation, technical difficulties or patient comorbidities can lead to non-eligibility for CA. Accordingly, a rationale exists to adopt more effective and less invasive therapies.
A promising novel non-invasive treatment option for refractory VT is stereotactic arrhythmia radio-ablation (STAR), originally born for cancer treatment, which consists in the application of high-energy photons in a single 25 Gy dose to limited areas of the ventricles, also to those inaccessible for CA, recognized through non-invasive surface ECG-mapping as the origin of VT. Preliminary small case series described good tolerance and improved VT burden during follow-up.
Due to the encouraging physical and biological characteristics of protons and carbon ions, the dose to surrounding healthy tissues could potentially be better spared in comparison with photons. Especially, the cardiac healthy sub-structures might benefit from the use of particle beams instead of photons. On the other hand, due to range uncertainties affecting particle beams, delivering an ideal radiation treatment with heavy ions to fast-moving targets such as the heart, is more complex. So far, the feasibility and the safety of cardiac radiotherapy with protons and heavy ions have only been evaluated in animal models and recently in the first in man case managed by the collaboration between CNAO and San Matteo Cardiology Department in a patient treated with compassionate aim.
To date, feasibility and safety data showing potential advantages of particles over photon therapy in dose distributions are missing.
Therefore, we propose a study aimed to compare different radiation therapy treatment modalities (photons vs. particle therapy: protons and carbon ions) simulating the RT treatment of ventricular arrhythmias on real patients candidates to invasive catheter ablation treatment.
STAR with photons was first reported in 2013 and an increasingly number of case reports and case series have been published ever since, showing an acceptable safety profile and promising efficacy.
Decreasing the dose to the surrounding healthy heart tissues is expected to be very advantageous for patients.
Particle therapy based on its dosimetric physical selectivity compared to SBRT (Stereotactic Body Radiotherapy) with photons might have the potential to both lower off-target doses and lower risk of possible side effects.
연구 개요
연구 유형
등록 (실제)
연락처 및 위치
연구 장소
-
-
Pavia
-
Pavia, Pavia, 이탈리아, 27100
- SC Cardiologia, Fondazione IRCCS Policlinico San Matteo
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Recurrent VT with clinical indication to receive catheter ablation
- Written informed consent
- Patient's ability to understand the characteristics and consequences of the clinical study
- Invasive mapping data
Exclusion Criteria:
- Allergy to iodinated contrast media
- Pregnancy and breastfeeding
- Younger than 18 years
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
|---|
|
Photons (control group)
"Stereotactic arrhythmia radioablation" (STAR) based on the delivery of a high, single dose (25 Gy) of photons to selected cardiac tissue (to limited areas of the ventricles), also to those inaccessible for CA, recognized through non-invasive surface ECG-mapping as the origin of VT.
|
|
Particle therapy with Protons and Carbon ions (Intervention group)
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Feasibility of particle therapy (protons and carbon ions)
기간: up to 3 years
|
To verify the feasibility of particle therapy plans in patients with refractory VT. Plans will be considered feasible whether the dosimetric criteria outlined will be achieved in no fewer than 90% of enrolled patients (30 enrolled patients). |
up to 3 years
|
|
Dose sparing on surrounding non-target tissues with particle therapy (protons and carbon ions)
기간: up to 3 years
|
To compare simulated RT plans with protons, carbon ions and photons, and quantify the differences in terms of dose released to surrounding cardiac and non-cardiac healthy tissues. Comparison of simulated RT plans, with protons, carbon ions and photons, by using cardiac motion management, optimizing the treatment plan on different cardiac phases at ECG-gated CT scan and ECG-gated radiotherapy beams delivery, for the same cardiac targets, will be done in terms of planned target coverage (target conformity index) and dose-volume histograms (DVH). |
up to 3 years
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Integration of ECGi Mapping into Planning CT for Target Contouring
기간: up to 3 years
|
To collect preliminary data of non-invasive electrocardiographic mapping (ECGi) usage for target definition in the setting of STAR, including the possibility of directly incorporating ECGi non-invasive mapping data into the planning CT to minimize potential mistakes in contouring the target.
|
up to 3 years
|
|
Feasibility and interferences of Ultrasound Probe on RT treatment planning
기간: up to 3 years
|
To verify the feasibility and possible interferences with simulated RT treatment planning of the use of an ultrasound probe (for online cardiac localization during beam delivery), positioned on the chest wall of patients during the imaging phase. The feasibility will not be achieved in case the limited beam angles due to the probe position do not allow to achieve the dosimetric plan criteria outlined in table 1 in more than 10% of the enrolled patients. |
up to 3 years
|
|
Development of Automatic Image Alignment
기간: up to 3 years
|
To develop and assess techniques for the automatic alignment of different images including CT and electroanatomic maps (EAM), to compose a single multimodal ventricular image where ablation planning can be more easily performed.
|
up to 3 years
|
|
Optimizing Arrhythmogenic Site Detection with Advanced Signal Processing Tools
기간: up to 3 years
|
To develop and assess techniques for the advanced simulation of the patient's ventricle by electrophysiological modelling customized on the EAM and the associated electrical information, to allow an in-silico test of the planned ablation strategy on a digital twin. Optimal identification of arrhythmogenic sites will also be pursued by the adoption of novel signal and information processing tools that have already demonstrated to be effective in the local identification of abnormal ventricular potentials. |
up to 3 years
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
추가 관련 MeSH 약관
기타 연구 ID 번호
- CARA-VT
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .