CARA-VT: a Dosimetric in Silico Study (CARA-VT)
Non-invasive CArdiac RAdioablation for Ventricular Tachycardia: a Feasibility Dosimetric in Silico Study Based on a Prospective Cohort of Patients to Compare Photon to Proton and to Carbon Ion Radiotherapy
Ventricular tachycardia (VT) is a potentially deadly condition, common in patients with structural heart disease or dilated cardiomyopathy. VTpatients are currently treated with anti-arrhythmic drugs, implanted cardioverter defibrillators or invasive catheter ablation (CA) but the overall success rate of this techniqueis still suboptimal.
One of the main reasons is an anatomically inaccessible location of VT's origin (within the mid-wall of the myocardium, on the epicardial site or adjacent to critical structures). Moreover, repeated invasive ablation, technical difficulties or patient comorbidities can lead to non-eligibility for CA. Accordingly, a rationale exists to adopt more effective and less invasive therapies.
A promising novel non-invasive treatment option for refractory VT is stereotactic arrhythmia radio-ablation (STAR), originally born for cancer treatment, which consists in the application of high-energy photons in a single 25 Gy dose to limited areas of the ventricles, also to those inaccessible for CA, recognized through non-invasive surface ECG-mapping as the origin of VT. Preliminary small case series described good tolerance and improved VT burden during follow-up.
Due to the encouraging physical and biological characteristics of protons and carbon ions, the dose to surrounding healthy tissues could potentially be better spared in comparison with photons. Especially, the cardiac healthy sub-structures might benefit from the use of particle beams instead of photons. On the other hand, due to range uncertainties affecting particle beams, delivering an ideal radiation treatment with heavy ions to fast-moving targets such as the heart, is more complex. So far, the feasibility and the safety of cardiac radiotherapy with protons and heavy ions have only been evaluated in animal models and recently in the first in man case managed by the collaboration between CNAO and San Matteo Cardiology Department in a patient treated with compassionate aim.
To date, feasibility and safety data showing potential advantages of particles over photon therapy in dose distributions are missing.
Therefore, we propose a study aimed to compare different radiation therapy treatment modalities (photons vs. particle therapy: protons and carbon ions) simulating the RT treatment of ventricular arrhythmias on real patients candidates to invasive catheter ablation treatment.
STAR with photons was first reported in 2013 and an increasingly number of case reports and case series have been published ever since, showing an acceptable safety profile and promising efficacy.
Decreasing the dose to the surrounding healthy heart tissues is expected to be very advantageous for patients.
Particle therapy based on its dosimetric physical selectivity compared to SBRT (Stereotactic Body Radiotherapy) with photons might have the potential to both lower off-target doses and lower risk of possible side effects.
研究概览
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
Pavia
-
Pavia、Pavia、意大利、27100
- SC Cardiologia, Fondazione IRCCS Policlinico San Matteo
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
- Recurrent VT with clinical indication to receive catheter ablation
- Written informed consent
- Patient's ability to understand the characteristics and consequences of the clinical study
- Invasive mapping data
Exclusion Criteria:
- Allergy to iodinated contrast media
- Pregnancy and breastfeeding
- Younger than 18 years
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
|---|
|
Photons (control group)
"Stereotactic arrhythmia radioablation" (STAR) based on the delivery of a high, single dose (25 Gy) of photons to selected cardiac tissue (to limited areas of the ventricles), also to those inaccessible for CA, recognized through non-invasive surface ECG-mapping as the origin of VT.
|
|
Particle therapy with Protons and Carbon ions (Intervention group)
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Feasibility of particle therapy (protons and carbon ions)
大体时间:up to 3 years
|
To verify the feasibility of particle therapy plans in patients with refractory VT. Plans will be considered feasible whether the dosimetric criteria outlined will be achieved in no fewer than 90% of enrolled patients (30 enrolled patients). |
up to 3 years
|
|
Dose sparing on surrounding non-target tissues with particle therapy (protons and carbon ions)
大体时间:up to 3 years
|
To compare simulated RT plans with protons, carbon ions and photons, and quantify the differences in terms of dose released to surrounding cardiac and non-cardiac healthy tissues. Comparison of simulated RT plans, with protons, carbon ions and photons, by using cardiac motion management, optimizing the treatment plan on different cardiac phases at ECG-gated CT scan and ECG-gated radiotherapy beams delivery, for the same cardiac targets, will be done in terms of planned target coverage (target conformity index) and dose-volume histograms (DVH). |
up to 3 years
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Integration of ECGi Mapping into Planning CT for Target Contouring
大体时间:up to 3 years
|
To collect preliminary data of non-invasive electrocardiographic mapping (ECGi) usage for target definition in the setting of STAR, including the possibility of directly incorporating ECGi non-invasive mapping data into the planning CT to minimize potential mistakes in contouring the target.
|
up to 3 years
|
|
Feasibility and interferences of Ultrasound Probe on RT treatment planning
大体时间:up to 3 years
|
To verify the feasibility and possible interferences with simulated RT treatment planning of the use of an ultrasound probe (for online cardiac localization during beam delivery), positioned on the chest wall of patients during the imaging phase. The feasibility will not be achieved in case the limited beam angles due to the probe position do not allow to achieve the dosimetric plan criteria outlined in table 1 in more than 10% of the enrolled patients. |
up to 3 years
|
|
Development of Automatic Image Alignment
大体时间:up to 3 years
|
To develop and assess techniques for the automatic alignment of different images including CT and electroanatomic maps (EAM), to compose a single multimodal ventricular image where ablation planning can be more easily performed.
|
up to 3 years
|
|
Optimizing Arrhythmogenic Site Detection with Advanced Signal Processing Tools
大体时间:up to 3 years
|
To develop and assess techniques for the advanced simulation of the patient's ventricle by electrophysiological modelling customized on the EAM and the associated electrical information, to allow an in-silico test of the planned ablation strategy on a digital twin. Optimal identification of arrhythmogenic sites will also be pursued by the adoption of novel signal and information processing tools that have already demonstrated to be effective in the local identification of abnormal ventricular potentials. |
up to 3 years
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
关键字
其他研究编号
- CARA-VT
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.