- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07590908
CARA-VT: a Dosimetric in Silico Study (CARA-VT)
Non-invasive CArdiac RAdioablation for Ventricular Tachycardia: a Feasibility Dosimetric in Silico Study Based on a Prospective Cohort of Patients to Compare Photon to Proton and to Carbon Ion Radiotherapy
Ventricular tachycardia (VT) is a potentially deadly condition, common in patients with structural heart disease or dilated cardiomyopathy. VTpatients are currently treated with anti-arrhythmic drugs, implanted cardioverter defibrillators or invasive catheter ablation (CA) but the overall success rate of this techniqueis still suboptimal.
One of the main reasons is an anatomically inaccessible location of VT's origin (within the mid-wall of the myocardium, on the epicardial site or adjacent to critical structures). Moreover, repeated invasive ablation, technical difficulties or patient comorbidities can lead to non-eligibility for CA. Accordingly, a rationale exists to adopt more effective and less invasive therapies.
A promising novel non-invasive treatment option for refractory VT is stereotactic arrhythmia radio-ablation (STAR), originally born for cancer treatment, which consists in the application of high-energy photons in a single 25 Gy dose to limited areas of the ventricles, also to those inaccessible for CA, recognized through non-invasive surface ECG-mapping as the origin of VT. Preliminary small case series described good tolerance and improved VT burden during follow-up.
Due to the encouraging physical and biological characteristics of protons and carbon ions, the dose to surrounding healthy tissues could potentially be better spared in comparison with photons. Especially, the cardiac healthy sub-structures might benefit from the use of particle beams instead of photons. On the other hand, due to range uncertainties affecting particle beams, delivering an ideal radiation treatment with heavy ions to fast-moving targets such as the heart, is more complex. So far, the feasibility and the safety of cardiac radiotherapy with protons and heavy ions have only been evaluated in animal models and recently in the first in man case managed by the collaboration between CNAO and San Matteo Cardiology Department in a patient treated with compassionate aim.
To date, feasibility and safety data showing potential advantages of particles over photon therapy in dose distributions are missing.
Therefore, we propose a study aimed to compare different radiation therapy treatment modalities (photons vs. particle therapy: protons and carbon ions) simulating the RT treatment of ventricular arrhythmias on real patients candidates to invasive catheter ablation treatment.
STAR with photons was first reported in 2013 and an increasingly number of case reports and case series have been published ever since, showing an acceptable safety profile and promising efficacy.
Decreasing the dose to the surrounding healthy heart tissues is expected to be very advantageous for patients.
Particle therapy based on its dosimetric physical selectivity compared to SBRT (Stereotactic Body Radiotherapy) with photons might have the potential to both lower off-target doses and lower risk of possible side effects.
Przegląd badań
Status
Warunki
Typ studiów
Zapisy (Rzeczywisty)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Pavia
-
Pavia, Pavia, Włochy, 27100
- SC Cardiologia, Fondazione IRCCS Policlinico San Matteo
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Recurrent VT with clinical indication to receive catheter ablation
- Written informed consent
- Patient's ability to understand the characteristics and consequences of the clinical study
- Invasive mapping data
Exclusion Criteria:
- Allergy to iodinated contrast media
- Pregnancy and breastfeeding
- Younger than 18 years
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Kohorty i interwencje
Grupa / Kohorta |
|---|
|
Photons (control group)
"Stereotactic arrhythmia radioablation" (STAR) based on the delivery of a high, single dose (25 Gy) of photons to selected cardiac tissue (to limited areas of the ventricles), also to those inaccessible for CA, recognized through non-invasive surface ECG-mapping as the origin of VT.
|
|
Particle therapy with Protons and Carbon ions (Intervention group)
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Feasibility of particle therapy (protons and carbon ions)
Ramy czasowe: up to 3 years
|
To verify the feasibility of particle therapy plans in patients with refractory VT. Plans will be considered feasible whether the dosimetric criteria outlined will be achieved in no fewer than 90% of enrolled patients (30 enrolled patients). |
up to 3 years
|
|
Dose sparing on surrounding non-target tissues with particle therapy (protons and carbon ions)
Ramy czasowe: up to 3 years
|
To compare simulated RT plans with protons, carbon ions and photons, and quantify the differences in terms of dose released to surrounding cardiac and non-cardiac healthy tissues. Comparison of simulated RT plans, with protons, carbon ions and photons, by using cardiac motion management, optimizing the treatment plan on different cardiac phases at ECG-gated CT scan and ECG-gated radiotherapy beams delivery, for the same cardiac targets, will be done in terms of planned target coverage (target conformity index) and dose-volume histograms (DVH). |
up to 3 years
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Integration of ECGi Mapping into Planning CT for Target Contouring
Ramy czasowe: up to 3 years
|
To collect preliminary data of non-invasive electrocardiographic mapping (ECGi) usage for target definition in the setting of STAR, including the possibility of directly incorporating ECGi non-invasive mapping data into the planning CT to minimize potential mistakes in contouring the target.
|
up to 3 years
|
|
Feasibility and interferences of Ultrasound Probe on RT treatment planning
Ramy czasowe: up to 3 years
|
To verify the feasibility and possible interferences with simulated RT treatment planning of the use of an ultrasound probe (for online cardiac localization during beam delivery), positioned on the chest wall of patients during the imaging phase. The feasibility will not be achieved in case the limited beam angles due to the probe position do not allow to achieve the dosimetric plan criteria outlined in table 1 in more than 10% of the enrolled patients. |
up to 3 years
|
|
Development of Automatic Image Alignment
Ramy czasowe: up to 3 years
|
To develop and assess techniques for the automatic alignment of different images including CT and electroanatomic maps (EAM), to compose a single multimodal ventricular image where ablation planning can be more easily performed.
|
up to 3 years
|
|
Optimizing Arrhythmogenic Site Detection with Advanced Signal Processing Tools
Ramy czasowe: up to 3 years
|
To develop and assess techniques for the advanced simulation of the patient's ventricle by electrophysiological modelling customized on the EAM and the associated electrical information, to allow an in-silico test of the planned ablation strategy on a digital twin. Optimal identification of arrhythmogenic sites will also be pursued by the adoption of novel signal and information processing tools that have already demonstrated to be effective in the local identification of abnormal ventricular potentials. |
up to 3 years
|
Współpracownicy i badacze
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- CARA-VT
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Tachykardia komorowa
-
Institute for Clinical and Experimental MedicineZakończony
-
Columbia UniversityJeszcze nie rekrutacjaNiewydolność serca | Uderzenie | Krwawienie | Transplantacja serca | Zakrzepica LVAD (Left Ventricular Assist Device). | Zakrzepica; Tętnica
-
Shanghai MicroPort EP MedTech Co., Ltd.ZakończonyNapadowy częstoskurcz nadkomorowy | Częstoskurcz węzłowy nawrotny przedsionkowo-komorowy | Tachykardia wzajemna przedsionkowo -komorowaChiny
-
China National Center for Cardiovascular DiseasesXijing Hospital; Shanghai Zhongshan Hospital; First Affiliated Hospital Xi'an... i inni współpracownicyJeszcze nie rekrutacjaUderzenie | Zakrzepica | Krwawienie | Aspiryna | Terapia przeciwzakrzepowa | Krwawienie z przewodu pokarmowego związane z LVAD | Terapia przeciwpłytkowa | LVAD | Urządzenie wspomagające komorę | Zakrzepica LVAD (Left Ventricular Assist Device). | LVAD (urządzenie wspomagające lewą komorę) | Niepożądane zdarzenie związane...