Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

CARA-VT: a Dosimetric in Silico Study (CARA-VT)

12 maj 2026 uppdaterad av: Roberto Rordorf, Fondazione IRCCS Policlinico San Matteo di Pavia

Non-invasive CArdiac RAdioablation for Ventricular Tachycardia: a Feasibility Dosimetric in Silico Study Based on a Prospective Cohort of Patients to Compare Photon to Proton and to Carbon Ion Radiotherapy

Ventricular tachycardia (VT) is a potentially deadly condition, common in patients with structural heart disease or dilated cardiomyopathy. VTpatients are currently treated with anti-arrhythmic drugs, implanted cardioverter defibrillators or invasive catheter ablation (CA) but the overall success rate of this techniqueis still suboptimal.

One of the main reasons is an anatomically inaccessible location of VT's origin (within the mid-wall of the myocardium, on the epicardial site or adjacent to critical structures). Moreover, repeated invasive ablation, technical difficulties or patient comorbidities can lead to non-eligibility for CA. Accordingly, a rationale exists to adopt more effective and less invasive therapies.

A promising novel non-invasive treatment option for refractory VT is stereotactic arrhythmia radio-ablation (STAR), originally born for cancer treatment, which consists in the application of high-energy photons in a single 25 Gy dose to limited areas of the ventricles, also to those inaccessible for CA, recognized through non-invasive surface ECG-mapping as the origin of VT. Preliminary small case series described good tolerance and improved VT burden during follow-up.

Due to the encouraging physical and biological characteristics of protons and carbon ions, the dose to surrounding healthy tissues could potentially be better spared in comparison with photons. Especially, the cardiac healthy sub-structures might benefit from the use of particle beams instead of photons. On the other hand, due to range uncertainties affecting particle beams, delivering an ideal radiation treatment with heavy ions to fast-moving targets such as the heart, is more complex. So far, the feasibility and the safety of cardiac radiotherapy with protons and heavy ions have only been evaluated in animal models and recently in the first in man case managed by the collaboration between CNAO and San Matteo Cardiology Department in a patient treated with compassionate aim.

To date, feasibility and safety data showing potential advantages of particles over photon therapy in dose distributions are missing.

Therefore, we propose a study aimed to compare different radiation therapy treatment modalities (photons vs. particle therapy: protons and carbon ions) simulating the RT treatment of ventricular arrhythmias on real patients candidates to invasive catheter ablation treatment.

STAR with photons was first reported in 2013 and an increasingly number of case reports and case series have been published ever since, showing an acceptable safety profile and promising efficacy.

Decreasing the dose to the surrounding healthy heart tissues is expected to be very advantageous for patients.

Particle therapy based on its dosimetric physical selectivity compared to SBRT (Stereotactic Body Radiotherapy) with photons might have the potential to both lower off-target doses and lower risk of possible side effects.

Studieöversikt

Status

Avslutad

Studietyp

Observationell

Inskrivning (Faktisk)

23

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • Pavia
      • Pavia, Pavia, Italien, 27100
        • SC Cardiologia, Fondazione IRCCS Policlinico San Matteo

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen
  • Äldre vuxen

Tar emot friska volontärer

Nej

Testmetod

Sannolikhetsprov

Studera befolkning

Thirty patients suffering recurrent VT with clinical indication to receive invasive catheter ablation will be included in the study

Beskrivning

Inclusion Criteria:

  • Recurrent VT with clinical indication to receive catheter ablation
  • Written informed consent
  • Patient's ability to understand the characteristics and consequences of the clinical study
  • Invasive mapping data

Exclusion Criteria:

  • Allergy to iodinated contrast media
  • Pregnancy and breastfeeding
  • Younger than 18 years

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

Kohorter och interventioner

Grupp / Kohort
Photons (control group)
"Stereotactic arrhythmia radioablation" (STAR) based on the delivery of a high, single dose (25 Gy) of photons to selected cardiac tissue (to limited areas of the ventricles), also to those inaccessible for CA, recognized through non-invasive surface ECG-mapping as the origin of VT.
Particle therapy with Protons and Carbon ions (Intervention group)

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Feasibility of particle therapy (protons and carbon ions)
Tidsram: up to 3 years

To verify the feasibility of particle therapy plans in patients with refractory VT.

Plans will be considered feasible whether the dosimetric criteria outlined will be achieved in no fewer than 90% of enrolled patients (30 enrolled patients).

up to 3 years
Dose sparing on surrounding non-target tissues with particle therapy (protons and carbon ions)
Tidsram: up to 3 years

To compare simulated RT plans with protons, carbon ions and photons, and quantify the differences in terms of dose released to surrounding cardiac and non-cardiac healthy tissues.

Comparison of simulated RT plans, with protons, carbon ions and photons, by using cardiac motion management, optimizing the treatment plan on different cardiac phases at ECG-gated CT scan and ECG-gated radiotherapy beams delivery, for the same cardiac targets, will be done in terms of planned target coverage (target conformity index) and dose-volume histograms (DVH).

up to 3 years

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Integration of ECGi Mapping into Planning CT for Target Contouring
Tidsram: up to 3 years
To collect preliminary data of non-invasive electrocardiographic mapping (ECGi) usage for target definition in the setting of STAR, including the possibility of directly incorporating ECGi non-invasive mapping data into the planning CT to minimize potential mistakes in contouring the target.
up to 3 years
Feasibility and interferences of Ultrasound Probe on RT treatment planning
Tidsram: up to 3 years

To verify the feasibility and possible interferences with simulated RT treatment planning of the use of an ultrasound probe (for online cardiac localization during beam delivery), positioned on the chest wall of patients during the imaging phase.

The feasibility will not be achieved in case the limited beam angles due to the probe position do not allow to achieve the dosimetric plan criteria outlined in table 1 in more than 10% of the enrolled patients.

up to 3 years
Development of Automatic Image Alignment
Tidsram: up to 3 years
To develop and assess techniques for the automatic alignment of different images including CT and electroanatomic maps (EAM), to compose a single multimodal ventricular image where ablation planning can be more easily performed.
up to 3 years
Optimizing Arrhythmogenic Site Detection with Advanced Signal Processing Tools
Tidsram: up to 3 years

To develop and assess techniques for the advanced simulation of the patient's ventricle by electrophysiological modelling customized on the EAM and the associated electrical information, to allow an in-silico test of the planned ablation strategy on a digital twin.

Optimal identification of arrhythmogenic sites will also be pursued by the adoption of novel signal and information processing tools that have already demonstrated to be effective in the local identification of abnormal ventricular potentials.

up to 3 years

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

8 februari 2022

Primärt slutförande (Faktisk)

31 december 2025

Avslutad studie (Faktisk)

31 december 2025

Studieregistreringsdatum

Först inskickad

14 november 2025

Först inskickad som uppfyllde QC-kriterierna

12 maj 2026

Första postat (Faktisk)

15 maj 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

15 maj 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

12 maj 2026

Senast verifierad

1 maj 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

OBESLUTSAM

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera