Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

3D Printed Orthosis for Wrist Instability for Ehlers-Danlos Syndrome Patient

11 september 2026 bijgewerkt door: ELewis

Custom Orthotic Using 3D Printed and 3D Scanned Method

This study will determine if using 3D scanning and 3D printing technology to create an orthosis to improve the quality of life for people with Ehlers Danlos Syndrome (EDS) compared to existing prefabricated orthoses. Orthoses are often used by people with EDS to stabilize and support joints with hypermobile tissues. Improving the quality of life will mean that people can participate in daily self-care and/or recreational activities that they enjoy, such as gardening and cooking. The investigators also seek to find if this orthosis will decrease pain and reduce the number of dislocations and subluxations. All these changes could lead to better mental health, decreasing the fear and anxiety related to dislocations and pain.

Studie Overzicht

Gedetailleerde beschrijving

The purpose of this study is to examine the impact that a 3D-scanned and 3D-printed forearm wrist and hand orthosis has on function, pain and quality of life for people with Ehlers-Danlos Syndrome.

The goal of this research is to create a more supportive wrist hand orthosis for people with Ehlers-Danlos Syndrome (EDS) to prevent wrist dislocation using 3D scanning and 3D printing technologies with a biomedically safe material and address concerns for an underserved medical population. The investigators' goal is to create an orthosis that works better than the traditional ones by providing more support and decreasing pain for the participants with EDS. The investigators will create a custom 3D scanned and 3D printed wrist-hand orthotic for the participant and evaluate if there is a change on number of subluxation/dislocation due to Ehlers- Danlos syndrome as it relates to pain, activity participation and patient satisfaction. To assess this, the investigators will use patient-rated outcome measures, such as: the 0-100 Pain Scale, daily # of subluxation/dislocation occurrences, activity level via Health Assessment Questionnaire HAQ-D1, and the OPUS Satisfaction with Device and Services survey.

Aim 1: Develop a custom 3D-printed wrist-hand orthosis for participants with Ehlers-Danlos Syndrome (EDS) using 3D scanning and printing technologies.

The investigators will design and fabricate a custom orthosis tailored to each participant's unique anatomical needs using biomedically safe materials. The aim is to create an orthotic device that provides enhanced support to the wrist and hand, preventing subluxation and dislocation while minimizing pain compared to pre-fabricated orthoses.

Aim 2: Evaluate the effectiveness of the custom 3D-printed orthosis in changing the number of wrist subluxation/dislocation and changing the pain levels in participants with EDS.

The investigators will assess the effectiveness of the wrist-hand orthosis by measuring the frequency of subluxation/dislocation events and evaluating pain levels before and after wearing the device. The 0-100 Pain Scale will be used to quantify pain relief, and the occurrence of wrist subluxation/dislocation will be recorded to determine the device's impact on joint stability.

Aim 3: Assess the impact of the custom 3D-printed orthosis on activity participation and overall functional status in individuals with EDS.

The investigators will measure changes in activity levels and functional status using patient-reported outcome measures, including the Health Assessment Questionnaire HAQ-DI, and OPUS Satisfaction with Device and Services. These metrics will provide insight into the orthosis's ability to enhance participation in daily activities and improve overall quality of life for individuals with EDS.

Aim 4: Measure participant satisfaction with the custom 3D-printed orthosis. The investigators will use the OPUS Satisfaction with Device and Services survey to evaluate patient satisfaction with the orthosis. This will help determine whether the 3D-printed orthosis meets the unique needs and preferences of individuals with EDS in terms of comfort, functionality, and usability.

Studietype

Observationeel

Inschrijving (Werkelijk)

2

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Massachusetts
      • Lowell, Massachusetts, Verenigde Staten, 01854
        • UMass Lowell, Expanded Media Fabrication Lab

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Bemonsteringsmethode

Niet-waarschijnlijkheidssteekproef

Studie Bevolking

Individuals with hypermobile Ehlers-Danlos Syndrome with history of wrist pain and subluxations

Beschrijving

Inclusion Criteria:

  • English-speaking
  • 21 or older
  • Ehlers-Danlos syndrome
  • wrist hypermobility

Exclusion Criteria:

  • Under 21
  • pregnant women
  • prisoners
  • non-English-speaking
  • skin sensitivity

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
Interventie / Behandeling
Ehlers-Danlos Syndrome (EDS)
Individuals with EDS with symptoms of wrist subluxation or wrist dislocation causing limitation in participation in self-care and activities and social activities
Fabricate a Custom 3D scanned and 3D printed wrist-hand orthosis for a participant with EDS to measure the change in pain, number of daily wrist subluxation and change in participation in activities such as gardening and cooking. The investigators will use participant feedback to customize the fit and design of the orthosis for maximum comfort and effectiveness. The investigators are using HD (high definition) 3D scanning and 3D printing technology for a precise fit to prevent subluxation.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Wrist Joint Stability
Tijdsspanne: From enrollment to the end of intervention at 8 weeks
Change the frequency of daily wrist subluxations and dislocations over 8 weeks (0-100, lower number is better)
From enrollment to the end of intervention at 8 weeks
Change in Pain Rating in upper extremity for individuals with EDS
Tijdsspanne: From enrollment to the end of the intervention at 8 weeks
Change in pain as measured by the pain rating on the Health Assessment Questionnaire (HAQ-DI) (0-100 where 0=no pain and 100 = severe pain. Lower number is better)
From enrollment to the end of the intervention at 8 weeks
Change in Activity Participation for individuals with EDS
Tijdsspanne: From enrollment to the end of intervention at 8 weeks
Change in participation in daily activities, as indicated by improvements in the Health Assessment Questionnaire (HAQ-DI) (The 8 scores of the 8 sections are summed and divided by 8. The result is the DI or FDI, the disability index or functional disability index. Each question can be rated 0-3 with 0 representing better functional ability.)
From enrollment to the end of intervention at 8 weeks
Satisfaction of person with EDS with 3D Scanned and 3D printed orthosis
Tijdsspanne: From Enrollment to the end of intervention at 8 weeks
Change in satisfaction levels as measured by the OPUS Satisfaction with Device and Services survey Satisfaction With Device Score is the sum of the scores for items 1-11 (11 - 55). We will not use the "Satisfaction With Services Score is the sum of the scores for items 12-21 (10 - 50)". The higher the score the better the outcome
From Enrollment to the end of intervention at 8 weeks

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Sponsor

Onderzoekers

  • Hoofdonderzoeker: Erika S Lewis, PT, EdD, University of Massachusetts, Lowell

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

21 augustus 2025

Primaire voltooiing (Werkelijk)

6 augustus 2026

Studie voltooiing (Werkelijk)

6 augustus 2026

Studieregistratiedata

Eerst ingediend

30 mei 2025

Eerst ingediend dat voldeed aan de QC-criteria

29 april 2026

Eerst geplaatst (Werkelijk)

4 mei 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

14 september 2026

Laatste update ingediend die voldeed aan QC-criteria

11 september 2026

Laatst geverifieerd

1 april 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

JA

Beschrijving IPD-plan

Individual Participant Data Set - Pain rating, OPUS HQOL index, OPUS satisfaction with Device and Services survey (Devices only), # daily subluxations/dislocations Study Protocol Statistical Analysis Plan Informed Consent Form Data Monitoring Committee Charter - IRB Research integrity manager Clinical Study Report

IPD-tijdsbestek voor delen

June 2026 - June 2029

IPD-toegangscriteria voor delen

Other researchers in the field researching EDS or 3D scanning and 3D printed orthoses. We will share Pain rating, OPUS HQOL index, OPUS satisfaction with Device and Services survey. The researchers can contact us via email to access the information.

IPD delen Ondersteunend informatietype

  • LEERPROTOCOOL
  • SAP
  • ICF
  • MVO

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Ja

product vervaardigd in en geëxporteerd uit de V.S.

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren