Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Comparative Effects of Sensorimotor Interventions on Hand Performance With Stroke

15 mei 2026 bijgewerkt door: Gamze Demircioğlu, Atlas University

Comparative Effects of Sensorimotor Interventions on Hand Motor Function and Performance in Patients With Stroke

This randomized controlled trial investigated the comparative effects of sensory, motor, and combined sensorimotor interventions on hand motor function and behavioral performance in patients with stroke. The study focused on upper-extremity impairments, particularly deficits in hand strength, dexterity, and reaction time, which are common following stroke and substantially limit functional independence. Sensorimotor integration plays a critical role in motor recovery, as effective hand function depends on the interaction between sensory feedback and motor control mechanisms.

Participants with stroke were randomly assigned to sensory, motor, or combined sensorimotor intervention groups. The interventions were designed to target tactile perception, motor coordination, and integrated sensorimotor processing through attended active and passive stimulation approaches. Outcome measures included hand grip strength, manual dexterity, and reaction time, which were evaluated before and after the intervention period.

The findings demonstrated that sensorimotor-based rehabilitation approaches positively influenced upper-extremity motor performance and behavioral responses in stroke patients. In particular, combined sensorimotor interventions appeared to provide more comprehensive improvements by simultaneously enhancing sensory processing and motor execution. These results support the importance of integrating sensory-focused strategies into conventional motor rehabilitation programs to optimize neuroplasticity and functional recovery after stroke. The study contributes to the growing evidence supporting multidimensional rehabilitation approaches for improving hand function and sensorimotor performance in individuals with stroke.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Werkelijk)

81

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Istanbul
      • Kâğıthane, Istanbul, Turkije (Türkiye), 34408
        • Istanbul Atlas University

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Beschrijving

Inclusion Criteria:

  • Having the ability to verbally communicate to answer questions
  • Willingness to participate in the study
  • Having read and signed the informed consent form

Exclusion Criteria:

  • Having joint movement restriction in the upper extremity
  • Presence of skin injury or scarring on the hand or wrist
  • History of surgery on the upper extremity
  • Having an orthopedic problem in the upper extremity
  • Having a rheumatic disease
  • Having a neurological condition in the upper extremity
  • Having a severe mental or cognitive impairment

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Ander
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Sensory Exercise Group
The Sensory Exercise Group (SEG) participated in an intervention designed to enhance sensory awareness and integration. The protocol included tactile stimuli such as sand, sensory balls, fabrics with different textures, multisensory gels, brushing, vibration, and superficial massage to stimulate cutaneous receptors and enrich sensory input. Massage was applied with the participant in a supine position, elbows extended, and hands in a neutral position. All sessions were standardized using a digital stopwatch, and each intervention lasted approximately 15 minutes with equal time allocation across groups. This standardized timing ensured that observed effects were related to the intervention content rather than differences in exposure duration.
Experimenteel: Motor Exercise Group
The Motor Exercise Group (MEG) performed structured hand exercises including active range of motion exercises for the wrist and fingers, grip strengthening, stabilization exercises, and wrist flexion-extension exercises using elastic bands and dumbbells. Resistance levels were adjusted according to participant tolerance, and the protocol was applied only to the dominant side. Each exercise consisted of 5-7 repetitions and two sets, with 30-second rest intervals between sets.
Experimenteel: Combined Sensory and Motor Exercise Group
In the Combined Sensorimotor Group (CSMG), sensory and motor exercises were applied according to the protocols used in the Sensory Exercise Group (SEG) and Motor Exercise Group (MEG). However, each exercise was performed as a single set, with the remaining session time allocated to superficial massage and sensory stimulation. The sensory and motor components were administered sequentially, with each phase lasting approximately 7-8 minutes to maintain temporal balance within the session.
Geen tussenkomst: Control
The control group did not receive any additional treatments during the study period, allowing for a clear comparison between the experimental group and the baseline conditions.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Moberg Pick-up Test (MPUT)
Tijdsspanne: immediately after the intervention
Hand function was evaluated using the Moberg Pick-up Test (MPUT), a standardized method for assessing functional hand use and fine-motor skills, specifically measuring the ability to grasp and manipulate small objects. During the test, participants were instructed to pick up various small objects (e.g., coins and small blocks) and place them in a container as quickly as possible. During the test, the participants were instructed to pick up various small objects and place them in a container as quickly as possible. The assessment was conducted with the dominant hand, first with eyes open and then with eyes closed, to test sensory function. For each condition, the test was repeated three times, and the best performance time, recorded in seconds, was used for analysis. The objects used in the test were of similar size and required coordinated hand movements for successful completion, ensuring consistency in task difficulty
immediately after the intervention
Muscle Reaction Time
Tijdsspanne: immediately after the intervention
Light Trainer® system, which consists of a wireless lighting system with LED pods and a central controller. The participants were seated with their hands on the table, 40 cm apart, palms down, and elbows at 90°. The Light Trainer was positioned centrally 20 cm away from each hand. When the pod was illuminated, the participants were instructed to turn off the light as quickly as possible by touching it. Light activation was randomized to avoid predictability, requiring participants to respond based on light cues each time. In the first task, the participants used their dominant hand to turn off the light as quickly as possible. In the second task, they responded to a light signal by deactivating a predetermined light from two different colors using their dominant hand. Scale Range: No minimum or maximum value in milliseconds (lower time is better). Interpretation: Lower reaction times signify better outcomes, as they reflect faster muscle response to visual stimuli.
immediately after the intervention
Grip Strength (Measured Using Jamar Electronic Dynamometer)
Tijdsspanne: immediately after the intervention
Hand performance was assessed based on grip strength using a Takei Handheld Dynamometer (Takei Scientific Instruments Co., Tokyo, Japan). Participants were seated with elbows flexed at 90 degrees and forearms in a neutral position, and were instructed to squeeze the dynamometer with maximum force for 3-5 seconds, with the palm facing upwards. Each hand was tested three times with a 20-second rest between trials, and the highest value was recorded. This protocol ensures standardized and consistent results, with measurements documented in kilograms (kg) to provide reliable grip strength assessment. Scale Range: The dynamometer measures from 0 to 90 kg. Interpretation: Higher scores reflect stronger grip strength, which is indicative of better hand function.
immediately after the intervention

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

6 maart 2026

Primaire voltooiing (Werkelijk)

25 april 2026

Studie voltooiing (Werkelijk)

1 mei 2026

Studieregistratiedata

Eerst ingediend

11 mei 2026

Eerst ingediend dat voldeed aan de QC-criteria

11 mei 2026

Eerst geplaatst (Werkelijk)

15 mei 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

18 mei 2026

Laatste update ingediend die voldeed aan QC-criteria

15 mei 2026

Laatst geverifieerd

1 maart 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren