Low-Field MRI in Stroke Code Patients (LFMIS)
14 juli 2026 bijgewerkt door: Nyika D. Kruyt, Leiden University Medical Center
Validation of Low Field MRI in Patients With Stroke Symptoms Less Than 12 Hours
This study evaluates the accuracy and feasibility of a portable low-field MRI (Hyperfine) device in patients presenting to the emergency department with suspected acute stroke.
All enrolled patients undergo standard clinical imaging (CT, CT angiography, CT perfusion) and additionally receive a low-field MRI scan.
Low-field MRI findings are compared to routine CT imaging and final clinical diagnosis.
The study aims to determine whether low-field MRI can reliably detect acute ischemic stroke (including lacunar and large vessel occlusion), hemorrhagic stroke, and stroke mimics in the acute setting.
Secondary outcomes include feasibility measures such as scan time, completion rate, patient satisfaction, and adverse events.
Studie Overzicht
Toestand
Werving
Conditie
Interventie / Behandeling
Studietype
Observationeel
Inschrijving (Geschat)
80
Contacten en locaties
In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.
Studiecontact
- Naam: Nyika Kruyt, MD, PhD
- Telefoonnummer: +31 71 526 9111
- E-mail: n.d.kruyt@lumc.nl
Studie Contact Back-up
- Naam: Robert Croese
- E-mail: r.j.i.croese@lumc.nl
Studie Locaties
-
-
South Holland
-
Leiden, South Holland, Nederland, 2333ZA
- Werving
- Leiden University Medical Center
-
-
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Nee
Bemonsteringsmethode
Niet-waarschijnlijkheidssteekproef
Studie Bevolking
Adult patients presenting to the emergency department of a tertiary academic hospital (LUMC) with suspected acute stroke (stroke code activation) within 12 hours of symptom onset.
The study population includes patients with ischemic stroke (large vessel occlusion and lacunar), hemorrhagic stroke, and stroke mimics, reflecting real-world acute stroke diagnostics.
Beschrijving
Inclusion Criteria:
- Age ≥ 18 years
- Presentation with suspected acute stroke (stroke code activation by ambulance paramedics)
- Symptom onset < 12 hours prior to presentation
- Admission to the emergency department of the Leiden University Medical Center (LUMC) during office hours
- Undergoing standard-of-care head CT imaging at the emergency department
- Ability to provide informed consent (written or verbal in the acute setting, with deferred written consent if applicable)
Exclusion Criteria:
- Imminent death
- Severe claustrophobia preventing MRI
- Presence of MRI-incompatible implanted devices (e.g., pacemaker, cochlear implant, insulin pump)
- Known intra-ocular metallic foreign body or intracranial metallic clip/device identified on admission CT
- Pregnancy
- Acute life-threatening or disabling condition requiring immediate intervention that precludes study procedures
- Any study-related delay that could interfere with time-critical stroke treatments (intravenous thrombolysis or endovascular thrombectomy)
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Ischemic stroke - lacunar infarct
Patients with clinical and radiological suspicion of lacunar ischemic stroke (subcortical infarct).
These patients often receive additional conventional MRI during routine work-up for radiological confirmation.
All patients undergo low-field MRI scanning in addition to routine clinical imaging.
|
Low-field MRI (Hyperfine Swoop, 0.064 Tesla) is performed once, in addition to routine clinical imaging (non-contrast CT, CT angiography, and CT perfusion as clinically indicated).
The scan is acquired after routine imaging and after initial treatment decisions, during office hours, with the patient on their ED bed.
Scan duration and any interruptions are recorded.
|
|
Hemorrhagic stroke
Patients with hemorrhagic stroke (intracerebral hemorrhage) demonstrated on non-contrast CT at the emergency department.
All patients undergo low-field MRI scanning in addition to routine clinical imaging.
|
Low-field MRI (Hyperfine Swoop, 0.064 Tesla) is performed once, in addition to routine clinical imaging (non-contrast CT, CT angiography, and CT perfusion as clinically indicated).
The scan is acquired after routine imaging and after initial treatment decisions, during office hours, with the patient on their ED bed.
Scan duration and any interruptions are recorded.
|
|
Stroke mimic
Patients with non-stroke diagnosis based on clinical judgment and neuro-imaging at the emergency department (e.g., epilepsy, migraine, functional neurological disorder).
All patients undergo low-field MRI scanning in addition to routine clinical imaging.
|
Low-field MRI (Hyperfine Swoop, 0.064 Tesla) is performed once, in addition to routine clinical imaging (non-contrast CT, CT angiography, and CT perfusion as clinically indicated).
The scan is acquired after routine imaging and after initial treatment decisions, during office hours, with the patient on their ED bed.
Scan duration and any interruptions are recorded.
|
|
Ischemic stroke - proximal vessel occlusion
Patients with ischemic stroke due to proximal vessel occlusion in the anterior circulation (large vessel occlusion, LVO) diagnosed by CT angiography at the emergency department.
All patients in this group undergo low-field MRI scanning in addition to routine clinical imaging.
|
Low-field MRI (Hyperfine Swoop, 0.064 Tesla) is performed once, in addition to routine clinical imaging (non-contrast CT, CT angiography, and CT perfusion as clinically indicated).
The scan is acquired after routine imaging and after initial treatment decisions, during office hours, with the patient on their ED bed.
Scan duration and any interruptions are recorded.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Diagnostic accuracy of low-field MRI for acute stroke detection
Tijdsspanne: At time of low-field MRI scan (within 12 hours of symptom onset)
|
Sensitivity, specificity, positive predictive value, and negative predictive value of low-field MRI findings for detecting acute stroke (ischemic or hemorrhagic) and stroke mimics, using final clinical diagnosis at discharge as the reference standard.
Low-field MRI images are assessed by a neuroradiologist blinded to CT findings and final diagnosis.
|
At time of low-field MRI scan (within 12 hours of symptom onset)
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Adverse events during low-field MRI scanning
Tijdsspanne: During low-field MRI scan and up to 30 minutes thereafter
|
Number and type of adverse events (AEs) and serious adverse events (SAEs) occurring during the low-field MRI scanning procedure or within 30 minutes after completion.
|
During low-field MRI scan and up to 30 minutes thereafter
|
|
Patient satisfaction with low-field MRI procedure
Tijdsspanne: Within 24 hours after low-field MRI scan.
|
Patient-reported satisfaction with the low-field MRI scanning experience, assessed using a structured questionnaire or verbal interview.
|
Within 24 hours after low-field MRI scan.
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Sponsor
Publicaties en nuttige links
De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.
Algemene publicaties
- Mazurek MH, Cahn BA, Yuen MM, Prabhat AM, Chavva IR, Shah JT, Crawford AL, Welch EB, Rothberg J, Sacolick L, Poole M, Wira C, Matouk CC, Ward A, Timario N, Leasure A, Beekman R, Peng TJ, Witsch J, Antonios JP, Falcone GJ, Gobeske KT, Petersen N, Schindler J, Sansing L, Gilmore EJ, Hwang DY, Kim JA, Malhotra A, Sze G, Rosen MS, Kimberly WT, Sheth KN. Portable, bedside, low-field magnetic resonance imaging for evaluation of intracerebral hemorrhage. Nat Commun. 2021 Aug 25;12(1):5119. doi: 10.1038/s41467-021-25441-6.
- Sheth KN, Mazurek MH, Yuen MM, Cahn BA, Shah JT, Ward A, Kim JA, Gilmore EJ, Falcone GJ, Petersen N, Gobeske KT, Kaddouh F, Hwang DY, Schindler J, Sansing L, Matouk C, Rothberg J, Sze G, Siner J, Rosen MS, Spudich S, Kimberly WT. Assessment of Brain Injury Using Portable, Low-Field Magnetic Resonance Imaging at the Bedside of Critically Ill Patients. JAMA Neurol. 2020 Sep 8;78(1):41-7. doi: 10.1001/jamaneurol.2020.3263. Online ahead of print.
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start (Werkelijk)
20 april 2026
Primaire voltooiing (Geschat)
1 april 2027
Studie voltooiing (Geschat)
1 augustus 2027
Studieregistratiedata
Eerst ingediend
3 juli 2026
Eerst ingediend dat voldeed aan de QC-criteria
10 juli 2026
Eerst geplaatst (Werkelijk)
14 juli 2026
Updates van studierecords
Laatste update geplaatst (Werkelijk)
16 juli 2026
Laatste update ingediend die voldeed aan QC-criteria
14 juli 2026
Laatst geverifieerd
1 juli 2026
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- NL87809.058.24
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
NEE
Beschrijving IPD-plan
Due to the limited sample size, the single-centre design, and privacy considerations under GDPR, there is no plan to share individual participant data.
Aggregate results will be published in peer-reviewed journals and presented at scientific meetings.
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Nee
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Ja
product vervaardigd in en geëxporteerd uit de V.S.
Ja
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .