Observational Data Collection for Blood Hemoglobin Algorithm Validation in Pediatrics
Prospective Observational Data Collection Study for Validation of a Near-Infrared Spectroscopy-Based Blood Hemoglobin Algorithm in Pediatric Patients Undergoing Cardiac Surgery or Cardiac Catheterization
This study will enroll children and young adults who are scheduled to undergo planned heart surgery or a heart catheterization procedure while under general anesthesia. Researchers will collect information from a forehead sensor that measures oxygen levels in the body's tissues, along with blood hemoglobin measurements obtained from blood samples that are already being collected as part of routine medical care.
The goal of the study is to determine whether a blood hemoglobin monitoring method that has already been cleared by the U.S. Food and Drug Administration (FDA) for use in adults may also work well in pediatric patients.
Studie Overzicht
Toestand
Interventie / Behandeling
Gedetailleerde beschrijving
Background:
Continuous monitoring of blood hemoglobin levels may help clinicians identify changes in a patient's blood status during surgery and support decisions regarding blood transfusion. A noninvasive blood hemoglobin monitoring method has been developed using near-infrared spectroscopy (NIRS) technology incorporated into the ForeSight Tissue Oximetry System. This technology uses near-infrared light to measure tissue oxygenation and derive information related to blood hemoglobin levels. An algorithm based on these measurements has been validated and cleared by the U.S. Food and Drug Administration (FDA) for use in adult patients.
Study Purpose:
The purpose of this study is to collect synchronized physiologic and laboratory data from pediatric patients to evaluate the feasibility and performance of applying an FDA-cleared adult blood hemoglobin algorithm to pediatric populations. The study will compare hemoglobin values estimated by the algorithm with reference hemoglobin values measured from arterial blood samples using standard blood-gas/co-oximetry analysis.
Study Design:
This is a prospective observational study conducted at Boston Children's Hospital. Pediatric patients undergoing elective cardiac surgery or elective cardiac catheterization procedures under general anesthesia will be eligible for participation. No investigational devices will be used, and participation in the study will not alter routine clinical care.
Study Procedures:
Following enrollment and informed consent, ForeSight tissue oximetry sensors will be placed on the patient's forehead as part of routine monitoring. One or two sensors may be used depending on patient size and available forehead surface area. The sensors will remain in place during the procedure and will continuously record tissue oxygenation and related physiologic signals.
Arterial blood samples obtained as part of routine clinical care will be used to measure blood hemoglobin levels using a blood-gas/co-oximetry analyzer. In some patients, up to two additional blood samples may be collected to strengthen the evaluation dataset. The amount of blood collected for these additional samples will be minimal.
Additional data collected will include demographic information, procedure type, standard physiologic monitoring parameters (such as heart rate, blood pressure, oxygen saturation, respiratory measurements, and temperature), laboratory values, administered medications and blood products, and clinically significant hemodynamic events documented during the procedure.
Data Handling:
Data collected from the monitoring system and clinical records will be linked and subsequently de-identified by authorized study personnel. Personal identifiers will be removed before data are shared with the study sponsor. The sponsor will have access only to de-identified study data.
Outcome Evaluation:
The primary objective is to assess the agreement between hemoglobin values estimated by the NIRS-based algorithm and reference hemoglobin values measured from arterial blood samples. Study analyses will evaluate the accuracy, bias, precision, and agreement of algorithm-derived hemoglobin measurements in pediatric patients. The results will help determine whether the adult FDA-cleared algorithm performs adequately in pediatric populations and will provide information to guide future clinical evaluation and regulatory activities related to noninvasive hemoglobin monitoring in children and adolescents.
Studietype
Inschrijving (Geschat)
Contacten en locaties
Studiecontact
- Naam: Dima Daaboul, MD
- Telefoonnummer: (617) 355-1370
- E-mail: dima.daaboul@childrens.harvard.edu
Studie Contact Back-up
- Naam: Barry Kussman, MBBCh, FFA(SA)
- Telefoonnummer: (617) 355-1370
- E-mail: Barry.Kussman@childrens.harvard.edu
Studie Locaties
-
-
Massachusetts
-
Boston, Massachusetts, Verenigde Staten, 02115
- Boston Children's Hospital
-
Contact:
- Rachel Bernier, MPH
- Telefoonnummer: 857-218-5348
- E-mail: rachel.bernier@childrens.harvard.edu
-
Contact:
- Jocelyn Booth, BSN
- Telefoonnummer: 857-218-4585
- E-mail: jocelyn.booth@childrens.harvard.edu
-
Hoofdonderzoeker:
- Dima Daaboul, MD
-
Onderonderzoeker:
- Barry Kussman, MBBCh, FFA(SA)
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Kind
- Volwassen
Accepteert gezonde vrijwilligers
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Age less than 21 years at the time of enrollment.
- Scheduled for elective cardiac surgery or elective cardiac catheterization under general anesthesia.
- Placement of an arterial catheter as part of routine clinical care for the procedure.
Exclusion Criteria:
- Presence of skin, scalp, or craniofacial abnormalities that prevent proper placement of the near-infrared spectroscopy (NIRS) sensor or may significantly affect measurement quality.
- Inability to obtain arterial blood hemoglobin measurements using standard clinical methods.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Pediatric Cardiac Surgery and Pediatric Catheterization Patients
This cohort includes pediatric patients undergoing elective cardiac surgery or elective cardiac catheterization under general anesthesia. All participants receive standard clinical care, including routine physiologic monitoring and arterial blood sampling when clinically indicated. As part of routine monitoring, a FDA-cleared near-infrared spectroscopy (NIRS)-based tissue oximetry system (ForeSight Tissue Oximetry System) will be placed on the forehead to continuously record cerebral tissue oxygenation during the procedure. Arterial blood samples obtained for clinical care will be analyzed using standard blood-gas/co-oximetry methods to measure blood hemoglobin levels. In select cases, a small number of additional blood samples may be collected to support data analysis. This is an observational study only. No investigational devices are used, no interventions are assigned, and there is no change to clinical management. All collected data are de-identified prior to analysis. |
This study evaluates noninvasive hemoglobin monitoring using a near-infrared spectroscopy (NIRS)-based tissue oximetry system in pediatric patients undergoing cardiac surgery or cardiac catheterization under general anesthesia. A FDA-cleared ForeSight Tissue Oximetry sensor is placed on the forehead to continuously measure tissue oxygenation, and an algorithm is derived to estimate hemoglobin. Reference hemoglobin values are obtained from arterial blood samples analyzed using standard blood-gas/co-oximetry methods as part of routine clinical care. A small number of additional samples may be collected if needed. The study compares noninvasive hemoglobin estimates with laboratory hemoglobin measurements. No investigational devices are used, and there is no change to clinical care. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Agreement Between Noninvasive and Invasive Hemoglobin Measurements
Tijdsspanne: Intraoperative period (from induction of general anesthesia until end of procedure)
|
The primary outcome measure is the agreement between NIRS-estimated hemoglobin and hemoglobin measured from arterial blood samples.
Both assessments measure hemoglobin concentration and will be reported in grams per deciliter (g/dL).
Agreement will be assessed by comparing paired hemoglobin measurements from the two methods.
The reported outcome will include the mean difference between the two measurements (g/dL) and the range of differences observed (g/dL).
|
Intraoperative period (from induction of general anesthesia until end of procedure)
|
Medewerkers en onderzoekers
Sponsor
Medewerkers
Onderzoekers
- Hoofdonderzoeker: Dima Daaboul, Boston Children's Hospital
Publicaties en nuttige links
Algemene publicaties
- Kussman BD, Wypij D, DiNardo JA, Newburger J, Jonas RA, Bartlett J, McGrath E, Laussen PC. An evaluation of bilateral monitoring of cerebral oxygen saturation during pediatric cardiac surgery. Anesth Analg. 2005 Nov;101(5):1294-1300. doi: 10.1213/01.ANE.0000180205.85490.85.
- van Wonderen SF, Aguirre A, Benni P, van den Dool REC, Macias Pingarron JP, Solares GJ, Hatib F, Veelo DP, Vlaar APJ, Jian Z. Continuous and Noninvasive Total Blood Hemoglobin Measurement Using Near-Infrared Reflectance Spectrometry. Anesth Analg. 2025 Nov 1;141(5):1107-1115. doi: 10.1213/ANE.0000000000007618. Epub 2025 Jul 2.
Nuttige links
- Manufacturer information for the HemoSphere advanced patient monitoring platform used to acquire tissue oximetry and hemodynamic data in this study.
- Manufacturer information for the ForeSight tissue oximetry sensor, which provides continuous noninvasive cerebral tissue oxygenation monitoring and tissue hemoglobin measurements used in this study
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- IRB-P00054090
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Beschrijving IPD-plan
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .