Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Impact of Entropy Monitoring on Anesthetic Consumption and Recovery After Laparoscopic Cholecystectomy

23 september 2026 bijgewerkt door: Muhammad Ali, KRL Hospital, Islamabad

Effect of Entropy Monitoring on Sevoflurane Consumption and Recovery From General Anesthesia in Patients Undergoing Laparoscopic Cholecystectomy

The goal of this clinical trial is to learn if brainwave-guided anesthesia (entropy monitoring) can reduce anesthetic drug consumption and speed up recovery time in adult patients undergoing elective laparoscopic cholecystectomy surgery under general anesthesia.

The main questions it aims to answer are:

  • Does entropy monitoring significantly decrease the mean consumption rate of sevoflurane gas (in mL/hr) compared to traditional clinical monitoring during surgery?
  • Does entropy monitoring significantly reduce the mean recovery time (in minutes to open eyes on verbal command) after discontinuing anesthesia? Researchers will compare patients whose anesthesia depth is guided by real-time entropy monitoring (brainwave and facial muscle sensors) to patients whose anesthesia is guided by standard clinical signs (heart rate and blood pressure) to see if using entropy sensors reduces total anesthetic gas use and enables faster patient recovery.

Participants will:

  • Receive routine pre-medication and general anesthesia induction for elective laparoscopic cholecystectomy.
  • Have continuous monitoring during surgery using either entropy brain/muscle sensors (Group A) or standard clinical vital signs (Group B) to guide the delivery of sevoflurane gas.
  • Have their total sevoflurane gas consumption rate automatically recorded at the end of surgery.
  • Be assessed after surgery for recovery time, measured in minutes from the time sevoflurane is turned off until they open their eyes upon verbal command.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Geschat)

120

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Locaties

      • Islamabad, Pakistan, 44000
        • Werving
        • KRL Hospital Islamabad
        • Contact:

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 60 jaar (Volwassen)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • ASA I or II
  • Elective laparoscopic cholecystectomy under GA

Exclusion Criteria:

  • Emergency cholecystectomy
  • Co Morbid (Hypertension, Diabetes Mellitus, Ischemic Heart Disease, Chronic Kidney Disease, Asthma, Stroke)
  • Known allergy or contraindication to sevoflurane or study drugs
  • Addictions such as chronic use of sedatives, hypnotics or alcohol abuse on medical records
  • BMI of 30 or greater (Obese patients tend to have delated recovery from general anesthesia)
  • Pregnancy

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Dubbele

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: Group A: Entropy Monitored Group

Device/Protocol: General anesthesia managed with Entropy Monitoring (GE Carestation 650). The anesthesiologist adjusts sevoflurane depth using real-time brain (EEG) and muscle (EMG) signals to maintain Response Entropy (RE) and State Entropy (SE) levels between 40 and 60, keeping the RE-SE difference under 10

Participants will receive general anesthesia via GE Carestation 650 Anesthesia Workstation equipped with Entropy module, maintained with sevoflurane in oxygen and air. Standard pre-medication (Midazolam 0.01-0.1 mg/kg and Nalbuphine 0.1 mg/kg), induction (Propofol in 10 mg increments), and neuromuscular blockade (Atracurium 0.5 mg/kg with NMT monitoring) will be administered. Anesthetic depth will be continuously monitored using forehead EEG/EMG sensors. The anesthesiologist will titrate the concentration of inhaled sevoflurane to maintain:

  1. Response Entropy (RE) and State Entropy (SE) target values strictly between 40 and 60 throughout the surgical procedure.
  2. A Response-State Entropy difference (RE-SE) of less than 10.
Actieve vergelijker: Group B: Clinically Monitored Group

Standard Care: General anesthesia managed using Standard Clinical Signs. The anesthesiologist adjusts sevoflurane levels based on standard clinical indicators (blood pressure, heart rate within ±20% of baseline, tearing, etc.) without using entropy numbers to guide drug dosing.

Participants will receive identical general anesthesia premedication, induction, and airway management protocols (Midazolam, Nalbuphine, Propofol, Atracurium, and maintenance with sevoflurane in oxygen and air) as Group A. Anesthetic depth will be guided strictly using traditional clinical parameters without the aid of entropy numbers. The anesthesiologist will titrate the concentration of inhaled sevoflurane to maintain:

Heart rate (HR) within ±20% of the patient's baseline value. Mean Arterial Pressure (MAP) within ±20% of the patient's baseline value. Clinical signs of light anesthesia (e.g., somatic movement, excessive lacrimation, or sweating).

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Sevoflurane Consumption
Tijdsspanne: End of surgery (from induction of anesthesia until gas discontinuation)

Total volume of liquid sevoflurane vaporized and delivered to the patient per hour. Automatically recorded by the GE Carestation 650 workstation

End of surgery (from induction of anesthesia until gas discontinuation)
Recovery Time
Tijdsspanne: From discontinuation of sevoflurane gas up to 60 minutes post-procedure

Time required for the patient to open their eyes following a verbal command after the flow of sevoflurane gas is turned off at the end of surgery

From discontinuation of sevoflurane gas up to 60 minutes post-procedure

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Studie stoel: Dr Humaira Jadoon, MBBS, FCPS Anesthesia, KRL Hospital, Islamabad

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 juli 2026

Primaire voltooiing (Geschat)

1 oktober 2026

Studie voltooiing (Geschat)

1 december 2026

Studieregistratiedata

Eerst ingediend

23 september 2026

Eerst ingediend dat voldeed aan de QC-criteria

23 september 2026

Eerst geplaatst (Werkelijk)

29 september 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

29 september 2026

Laatste update ingediend die voldeed aan QC-criteria

23 september 2026

Laatst geverifieerd

1 september 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • KRLHIslamabad

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Beschrijving IPD-plan

There is no plan to make IPD available

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .