The Response Patterns to the Electrical Stimulation of Epidural Catheters With Varying Pulse Widths in Term Pregnant Women

Epidural analgesia is commonly used for labor pain relief due to its safety and effectiveness. Despite a very high success rate, the epidural technique remains a somewhat blind technique and failures continue to occur. Unfortunately, there are no imaging techniques that can be used at the bedside to determine the proper positioning of the epidural catheter. The trans-catheter electric stimulation test (TCEST) has been successfully used for this purpose. This test is occasionally performed in situations where the immediate confirmation of the proper epidural catheter location is deemed necessary. The test helps to predict which epidurals might fail so that appropriate measures could be immediately implemented.

There has been one duration of electrical stimulus (0.2 milliseconds) that has been used in the majority of studies and in clinical practice. With this duration of stimulation, the vast majority of cases show a unilateral motor response of the lower limbs during the TCEST. Studies on the stimulation of peripheral nerves (nerves in the arms and legs) have shown that an electrical stimulus with a longer duration is able to stimulate nerves which are farther away. Since nerves in the epidural space are similar in composition to peripheral nerves, the investigators expect to see a higher rate of bilateral response with the longer duration of stimulus. The investigators also hope to show that this bilateral response is predictive of a better functioning epidural.

The investigators hypothesize that the incidence of a bilateral response to the TCEST will be higher with the 1.0 ms pulse width compared to 0.1 ms pulse width. Furthermore, the investigators hypothesize that a bilateral motor response associated with the 1.0 ms pulse width will be predictive of symmetry of sensory and motor block and of lower consumption of local anesthetic.

Przegląd badań

Status

Zakończony

Warunki

Interwencja / Leczenie

Szczegółowy opis

This will be a randomized double-blind controlled study. After recruitment of the patient, epidural anesthesia will be performed in the standard fashion employed in the investigators' institution by a fellow or staff. Spinal ultrasound will be used prior to performing the epidural catheter insertion. The trans-catheter electric stimulation test (TCEST) will be performed at both a 0.1ms pulse width and a 1ms pulse width. The order in which the two pulse widths are applied will be randomly decided by computer. The test dose of local anesthetic will then be administered, and the TCEST will be repeated 5 minutes later. Again, both pulse widths (0.1ms, 1ms) will be used, and the order in which they are applied will be decided randomly.

Following the second testing, a loading dose of the standard anesthetic solution will be administered. The sensory level to ice will be tested at 20 minutes following injection of the loading dose of bupivacaine and fentanyl. The sensory level will be assessed from the sacral to the thoracic levels, bilaterally. The motor response pattern will be recorded for all TCESTs performed, and any relationship between pulse width and response pattern will be determined.

Typ studiów

Interwencyjne

Zapisy (Rzeczywisty)

20

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

    • Ontario
      • Toronto, Ontario, Kanada, M5G1X5
        • Mount Sinai Hospital

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

16 lat do 55 lat (Dziecko, Dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Kobieta

Opis

Inclusion Criteria:

  • Women 16 years of age and older requesting an epidural for labour analgesia
  • Ability to communicate in English
  • Informed consent

Exclusion criteria:

  • Refusal to provide written informed consent
  • Inability to communicate in English
  • Abnormal vertebral anatomy, including but not limited to previous spine surgery and scoliosis
  • Allergy or hypersensitivity to lidocaine, bupivacaine or fentanyl
  • Coexisting neurological disorders
  • Implanted electronic devices

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Podwójnie

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Aktywny komparator: 0.1ms pulse width
The nerve stimulator will be connected to the epidural catheter through an adapter, which will be primed with a standard volume of 3 ml of sterile normal saline to allow for effective electrical conduction. The cathode terminal of the stimulator will then be attached to the metal hub of the adapter and the anode terminal will be connected to the electrode placed over the deltoid muscle. All patients will have the trans-catheter electric stimulation test (TCEST) performed with both a 1 ms pulse width and 0.1 ms pulse width and the order of administration will be randomized.
The nerve stimulator (Stimpod NMS 450: Xavant technology (PTY) Ltd; Pretoria, South Africa or similar nerve stimulator) will be connected to the epidural catheter through an adapter (Johans ECG Adapter, Arrow International Inc., Reading). The epidural catheter and the adapter will be primed with a standard volume of 3 ml of sterile normal saline to allow for effective electrical conduction. Secured connections and avoidance of any air within in the system must be ensured to avoid high impedance in the circuit, which could result in false negatives. The cathode terminal of the stimulator will then be attached to the metal hub of the adapter and the anode terminal will be connected to the electrode placed over the deltoid muscle.
Inne nazwy:
  • Stimpod NMS 450
Aktywny komparator: 1ms pulse width
The nerve stimulator will be connected to the epidural catheter through an adapter, which will be primed with a standard volume of 3 ml of sterile normal saline to allow for effective electrical conduction. The cathode terminal of the stimulator will then be attached to the metal hub of the adapter and the anode terminal will be connected to the electrode placed over the deltoid muscle. All patients will have the trans-catheter electric stimulation test (TCEST) performed with both a 1 ms pulse width and 0.1 ms pulse width and the order of administration will be randomized.
The nerve stimulator (Stimpod NMS 450: Xavant technology (PTY) Ltd; Pretoria, South Africa or similar nerve stimulator) will be connected to the epidural catheter through an adapter (Johans ECG Adapter, Arrow International Inc., Reading). The epidural catheter and the adapter will be primed with a standard volume of 3 ml of sterile normal saline to allow for effective electrical conduction. Secured connections and avoidance of any air within in the system must be ensured to avoid high impedance in the circuit, which could result in false negatives. The cathode terminal of the stimulator will then be attached to the metal hub of the adapter and the anode terminal will be connected to the electrode placed over the deltoid muscle.
Inne nazwy:
  • Stimpod NMS 450

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Motor response pattern
Ramy czasowe: 5 minutes
Motor response pattern to the electrical stimulation of the epidural catheter, either unilateral or bilateral.
5 minutes

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Sensory level
Ramy czasowe: 2 hours
The sensory level to ice at 20 minutes and 2 hours following injection of the standard epidural loading dose. The sensory level will be assessed from the sacral to the thoracic levels, bilaterally.
2 hours
Motor block
Ramy czasowe: 2 hours

Lower extremity motor block as assessed by the Bromage score (Range: 0-3) bilaterally at 20 minutes and 2 hours following the loading dose.

0 = No motor block (full flexion of knees and feet)

  1. = Partial motor block (just able to move knees and feet)
  2. = Almost complete motor block (able to move feet only)
  3. = Complete motor block (unable to move feet or knees)
2 hours
Current (mA)
Ramy czasowe: 5 minutes
The current required to elicit a motor response on the initial TCEST and at 5 minutes after the test dose
5 minutes
Consumption of local anesthetic
Ramy czasowe: 2 hours
Amount of local anesthetic consumed as measured on the pump in the first 2 hours.
2 hours
Epidural block failure
Ramy czasowe: 2 hours
Failure of the epidural analgesia, defined as no evidence of a sensory block to ice and absent pain relief in the first 20 minutes, OR the need for epidural catheter replacement within 2 hours of the loading dose.
2 hours

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

1 maja 2016

Zakończenie podstawowe (Rzeczywisty)

1 sierpnia 2016

Ukończenie studiów (Rzeczywisty)

1 sierpnia 2016

Daty rejestracji na studia

Pierwszy przesłany

2 maja 2016

Pierwszy przesłany, który spełnia kryteria kontroli jakości

3 maja 2016

Pierwszy wysłany (Oszacować)

4 maja 2016

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

1 sierpnia 2017

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

31 lipca 2017

Ostatnia weryfikacja

1 lipca 2017

Więcej informacji

Terminy związane z tym badaniem

Dodatkowe istotne warunki MeSH

Inne numery identyfikacyjne badania

  • 16-04

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj