Changes in Tear Lipid Layer Thickness After Short Exposure to Light Emitting Diode Displays
Video display terminals (VDTs) are ubiquitous, and engagement in digital screens has grown substantially across all age groups worldwide. Prolonged exposure to VDTs is associated with the development of various health problems. By now, it is unclear whether transient exposure to VDTs leads to ocular surface changes, especially regarding lipid layer thickness (LLT). This study aim to determine if short-term exposure to light-emitting diodes (LEDs) leads to ocular parameter changes.
This is a prospective, cross-sectional study. Patients were recruited at the National Cheng-Kung University Hospital, a tertiary referral center in southern Taiwan, for examination, including best-corrected visual acuity (BCVA), intraocular pressure (IOP), lipid layer thickness (LLT), and blink rates and patterns before and after watching an LED display for 15 minutes. The estimated result is that the LLT and blink rates will decrease after VDT watching.
Przegląd badań
Status
Interwencja / Leczenie
Szczegółowy opis
Video display terminals (VDTs) are ubiquitous, and engagement in digital screens has grown substantially across all age groups worldwide. During the coronavirus disease 2019 (COVID-19) pandemic, lockdowns and increasing demand for digital learning and working have led to more frequent and sustained VDT use. Prolonged exposure to VDTs is associated with the development of various health problems, including psychosocial issues, venous thromboembolism, fatigue, and visual complaints.
Computer vision syndrome (CVS) is one of the most frequently encountered problems among VDT users. CVS comprises several visual and musculoskeletal symptoms resulting from VDT use, such as eye strain, dryness and burning sensation of the eye, blurred vision, and neck and shoulder pain. A major alteration is the development of dry eye disease (DED), occurring in 60 % of those with CVS. Dry eye symptoms, corneal erosions, short tear-film breakup time (BUT), low tear meniscus height, and meibomian gland dysfunction (MGD) are all DED presentations encountered by VDT users. The continuous use of VDTs is an established risk factor for CVS and DED. However, it is unclear whether transient exposure to VDTs leads to ocular surface changes, especially regarding lipid layer thickness (LLT).
This study investigated if the short-term use of light-emitting diode (LED) displays (one type of VDT) changed the ocular parameters, including best-corrected visual acuity (BCVA), intraocular ocular pressure (IOP), the CVS-Questionnaire (CVS-Q) score, the blink rate, the partial blink ratio, and LLT. To our knowledge, this is the first study to focus on the immediate effects of LEDs on the eye.
This prospective clinical study was conducted in the Ophthalmology Department of the National Cheng Kung University Hospital (NCKUH), Tainan, Taiwan. The study was approved by the Institutional Review Board of NCKUH and followed the tenets of the Declaration of Helsinki. Written informed consent was obtained from all the participants.
The inclusion criteria were generally healthy individuals aged between 20 and 65 years who were willing to participate in the study. The exclusion criteria were ages below 20 or over 65 years, a BCVA score of <0.1 on the Landolt C chart in either eye, a BCVA difference of >0.2 between the eyes, and a history of ocular diseases or previous ocular surgery.
Participants were instructed to fill out a basic information form, including their name, sex, age, and contact information. They were also informed to avoid wearing contact lenses for two days before the test. The experiment was conducted on August 22, 2020. For the baseline test, the participants were asked to complete the CVS-Q to assess their CVS. Next was a series of ocular examinations, including BCVA, IOP, LLT, an optical coherence tomography (OCT) scan of the macula, and fundus autofluorescence (FAF) imaging. The LLT and blink rates were measured using the LipiView II Ocular Surface Interferometer following the standard protocol (TearScience, Morrisville, NC, USA). After the examination, the participants watched a short movie on an LED screen (InnoLux, Taiwan) for 15 minutes in a bright room. The viewing distance was approximately 1.5 meters. After the movie ended, the participants were instructed to complete the CVS-Q and undergo the BCVA, IOP, and LLT tests again. The baseline BCVA, IOP, OCT, and FAF images of each participant were reviewed by three NCKUH ophthalmologists to screen for clinically significant ocular pathology.
Statistical analyses were performed using R software version 4.1.0 (R Core Team, Vienna, Austria) and SAS Enterprise Guide (version 9.4; SAS Institute Inc., Cary, NC, USA). Paired t-tests were used to compare the BCVA, IOP, CVS-Q score, LLT, blink rate, and the partial blink ratio before and after watching the LED display. Statistical significance was set at P <0.05.
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Tainan, Tajwan
- National Cheng Kung University Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- generally healthy individuals aged between 20 and 65 years who were willing to participate in the study
Exclusion Criteria:
- ages below 20 or over 65 years
- a BCVA score of <0.1 on the Landolt C chart in either eye
- a BCVA difference of >0.2 between the eyes
- a history of ocular diseases or previous ocular surgery
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Inny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: LED screen
|
Participants watch a short movie on an LED screen (InnoLux, Taiwan) for 15 minutes in a bright room.
The viewing distance was approximately 1.5 meters.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Ramy czasowe |
|---|---|
|
Lipid Layer Thickness
Ramy czasowe: Change from baseline lipid layer thickness at 15 minutes
|
Change from baseline lipid layer thickness at 15 minutes
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Visual Acuity
Ramy czasowe: Change from baseline visual acuity at 15 minutes
|
Change from baseline visual acuity at 15 minutes
|
|
|
Intraocular Pressure
Ramy czasowe: Change from baseline intraocular pressure at 15 minutes
|
Change from baseline intraocular pressure at 15 minutes
|
|
|
Blink rates
Ramy czasowe: Change from baseline blink rates at 15 minutes
|
Change from baseline blink rates at 15 minutes
|
|
|
Computer Vision Syndrome Questionnaire Score
Ramy czasowe: Change from Baseline Computer Vision Syndrome Questionnaire Score at 15 minutes
|
The Computer Vision Syndrome Questionnaire is a validated questionnaire to assess the severity of the computer vision syndrome.
|
Change from Baseline Computer Vision Syndrome Questionnaire Score at 15 minutes
|
Współpracownicy i badacze
Współpracownicy
Śledczy
- Krzesło do nauki: Yi-Hsun Huang, PhD, National Cheng-Kung University Hospital
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- A-ER-108-489
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Opis planu IPD
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .