- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT05003128
Changes in Tear Lipid Layer Thickness After Short Exposure to Light Emitting Diode Displays
Video display terminals (VDTs) are ubiquitous, and engagement in digital screens has grown substantially across all age groups worldwide. Prolonged exposure to VDTs is associated with the development of various health problems. By now, it is unclear whether transient exposure to VDTs leads to ocular surface changes, especially regarding lipid layer thickness (LLT). This study aim to determine if short-term exposure to light-emitting diodes (LEDs) leads to ocular parameter changes.
This is a prospective, cross-sectional study. Patients were recruited at the National Cheng-Kung University Hospital, a tertiary referral center in southern Taiwan, for examination, including best-corrected visual acuity (BCVA), intraocular pressure (IOP), lipid layer thickness (LLT), and blink rates and patterns before and after watching an LED display for 15 minutes. The estimated result is that the LLT and blink rates will decrease after VDT watching.
Descripción general del estudio
Estado
Intervención / Tratamiento
Descripción detallada
Video display terminals (VDTs) are ubiquitous, and engagement in digital screens has grown substantially across all age groups worldwide. During the coronavirus disease 2019 (COVID-19) pandemic, lockdowns and increasing demand for digital learning and working have led to more frequent and sustained VDT use. Prolonged exposure to VDTs is associated with the development of various health problems, including psychosocial issues, venous thromboembolism, fatigue, and visual complaints.
Computer vision syndrome (CVS) is one of the most frequently encountered problems among VDT users. CVS comprises several visual and musculoskeletal symptoms resulting from VDT use, such as eye strain, dryness and burning sensation of the eye, blurred vision, and neck and shoulder pain. A major alteration is the development of dry eye disease (DED), occurring in 60 % of those with CVS. Dry eye symptoms, corneal erosions, short tear-film breakup time (BUT), low tear meniscus height, and meibomian gland dysfunction (MGD) are all DED presentations encountered by VDT users. The continuous use of VDTs is an established risk factor for CVS and DED. However, it is unclear whether transient exposure to VDTs leads to ocular surface changes, especially regarding lipid layer thickness (LLT).
This study investigated if the short-term use of light-emitting diode (LED) displays (one type of VDT) changed the ocular parameters, including best-corrected visual acuity (BCVA), intraocular ocular pressure (IOP), the CVS-Questionnaire (CVS-Q) score, the blink rate, the partial blink ratio, and LLT. To our knowledge, this is the first study to focus on the immediate effects of LEDs on the eye.
This prospective clinical study was conducted in the Ophthalmology Department of the National Cheng Kung University Hospital (NCKUH), Tainan, Taiwan. The study was approved by the Institutional Review Board of NCKUH and followed the tenets of the Declaration of Helsinki. Written informed consent was obtained from all the participants.
The inclusion criteria were generally healthy individuals aged between 20 and 65 years who were willing to participate in the study. The exclusion criteria were ages below 20 or over 65 years, a BCVA score of <0.1 on the Landolt C chart in either eye, a BCVA difference of >0.2 between the eyes, and a history of ocular diseases or previous ocular surgery.
Participants were instructed to fill out a basic information form, including their name, sex, age, and contact information. They were also informed to avoid wearing contact lenses for two days before the test. The experiment was conducted on August 22, 2020. For the baseline test, the participants were asked to complete the CVS-Q to assess their CVS. Next was a series of ocular examinations, including BCVA, IOP, LLT, an optical coherence tomography (OCT) scan of the macula, and fundus autofluorescence (FAF) imaging. The LLT and blink rates were measured using the LipiView II Ocular Surface Interferometer following the standard protocol (TearScience, Morrisville, NC, USA). After the examination, the participants watched a short movie on an LED screen (InnoLux, Taiwan) for 15 minutes in a bright room. The viewing distance was approximately 1.5 meters. After the movie ended, the participants were instructed to complete the CVS-Q and undergo the BCVA, IOP, and LLT tests again. The baseline BCVA, IOP, OCT, and FAF images of each participant were reviewed by three NCKUH ophthalmologists to screen for clinically significant ocular pathology.
Statistical analyses were performed using R software version 4.1.0 (R Core Team, Vienna, Austria) and SAS Enterprise Guide (version 9.4; SAS Institute Inc., Cary, NC, USA). Paired t-tests were used to compare the BCVA, IOP, CVS-Q score, LLT, blink rate, and the partial blink ratio before and after watching the LED display. Statistical significance was set at P <0.05.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Tainan, Taiwán
- National Cheng Kung University Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- generally healthy individuals aged between 20 and 65 years who were willing to participate in the study
Exclusion Criteria:
- ages below 20 or over 65 years
- a BCVA score of <0.1 on the Landolt C chart in either eye
- a BCVA difference of >0.2 between the eyes
- a history of ocular diseases or previous ocular surgery
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Otro
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: LED screen
|
Participants watch a short movie on an LED screen (InnoLux, Taiwan) for 15 minutes in a bright room.
The viewing distance was approximately 1.5 meters.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Lipid Layer Thickness
Periodo de tiempo: Change from baseline lipid layer thickness at 15 minutes
|
Change from baseline lipid layer thickness at 15 minutes
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Visual Acuity
Periodo de tiempo: Change from baseline visual acuity at 15 minutes
|
Change from baseline visual acuity at 15 minutes
|
|
|
Intraocular Pressure
Periodo de tiempo: Change from baseline intraocular pressure at 15 minutes
|
Change from baseline intraocular pressure at 15 minutes
|
|
|
Blink rates
Periodo de tiempo: Change from baseline blink rates at 15 minutes
|
Change from baseline blink rates at 15 minutes
|
|
|
Computer Vision Syndrome Questionnaire Score
Periodo de tiempo: Change from Baseline Computer Vision Syndrome Questionnaire Score at 15 minutes
|
The Computer Vision Syndrome Questionnaire is a validated questionnaire to assess the severity of the computer vision syndrome.
|
Change from Baseline Computer Vision Syndrome Questionnaire Score at 15 minutes
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Silla de estudio: Yi-Hsun Huang, PhD, National Cheng-Kung University Hospital
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- A-ER-108-489
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Descripción del plan IPD
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .