Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Temporal Interference Methods for Non-invasive Deep Brain Stimulation, Study 1.3

8 września 2026 zaktualizowane przez: Joshua Brown, PHD, Indiana University

Temporal Interference Methods for Non-invasive Deep Brain Stimulation

This grant aims to develop a line of research using temporal interference (TI) electrical neurostimulation technology to understand the causal role of deep brain structures in cognition. In the short term, the investigators aim to validate and characterize the effects of TI on brain activity as measured by fMRI and demonstrate its ability to focally stimulate deep brain regions without affecting overlying cortex. In the longer term, investigators aim to use these data to resolve longstanding debates about the function of deeper brain regions and lay the foundation for future clinical applications of TI for treating addiction, Obsessive-Compulsive Disorder (OCD), Parkinson's disease, and other disorders involving deep brain dysfunction. The grant supports 2 distinct aims, each of which will be evaluated through a series of independent studies.

Przegląd badań

Szczegółowy opis

Through the grant's duration, the investigators hypothesize that temporal interference (TI) electrical neurostimulation will be well tolerated and effective at focally manipulating deep brain activity as measured by functional MRI (fMRI) BOLD signals. The investigators will investigate whether TI stimulation can increase BOLD activity in targeted deep brain regions including the nucleus accumbens (NAcc) and dorsal anterior cingulate cortex (dACC), and whether this stimulation can influence cognitive functions controlled by these regions. TI works by applying alternating currents of slightly different frequencies through multiple electrode pairs, creating an interference pattern that can stimulate deep brain regions without significantly affecting superficial cortical areas. This method is similar to traditional transcranial direct current stimulation (tDCS), however TI can stimulate deeper brain structures that tDCS cannot reach effectively. The study is broken up into two main aims with multiple sub-studies. In Aim 1, the investigators will characterize the effects of TI on fMRI BOLD signals, test different beat frequencies, and compare TI effects in the nucleus accumbens versus dorsal anterior cingulate cortex. In Aim 2, the investigators will apply TI to the dorsal anterior cingulate cortex to test causal theories about its role in cognitive control, conflict monitoring, risk avoidance, and foraging behavior using established cognitive tasks while subjects undergo fMRI scanning.

Study 1.3 (Aim 1, Study 1.3) will test whether TI can focally modulate activity in the dorsal anterior cingulate cortex, around MNI coordinates 0, 30, 30, as measured by fMRI BOLD signal. Healthy subjects (n=30) will complete a single study visit during which they will undergo fMRI while receiving TI stimulation through carbon fiber electrodes attached to the scalp with conductive gel. Electrode placement may vary by participant to optimize dACC targeting using individualized finite element modeling.

Participants will receive active and sham TI stimulation at a selected beat frequency potentially including 5 Hz, 30 Hz, 40 Hz, or another frequency in the 1-100 Hz range. Stimulation will follow an on/off sequence of 2 minutes on, 2 minutes off, 2 minutes on, and 2 minutes off, with 30-second ramp up and ramp down periods beginning at the start of each 2-minute stimulation period. Study 1.3 will also examine whether increased stimulation intensity improves modulation of BOLD activity in the dACC. Stimulation may be delivered up to ±5 mA per channel, corresponding to 10 mA peak-to-peak, with the second stimulation channel linearly scaled based on individualized modeling to maintain optimal targeting. Active and sham stimulation blocks will be counterbalanced across subjects.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

30

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

  • Nazwa: Joshua W Brown, PhD
  • Numer telefonu: 812-855-9282
  • E-mail: cclab@iu.edu

Kopia zapasowa kontaktu do badania

  • Nazwa: Irene Jang, BS
  • Numer telefonu: 812-856-1846
  • E-mail: cclabmgr@iu.edu

Lokalizacje studiów

    • Indiana
      • Bloomington, Indiana, Stany Zjednoczone, 47408
        • Rekrutacyjny
        • Indiana University Bloomington, Imaging Research Facility
        • Kontakt:
          • Josh W Brown, PhD
          • Numer telefonu: 812-856-1846
          • E-mail: cclab@iu.edu
        • Kontakt:

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły

Akceptuje zdrowych ochotników

Tak

Opis

Inclusion Criteria:

  • Between the ages of 18 and 50
  • Must have at least a 6th grade education
  • Ability to speak and read English for all phases

Exclusion Criteria:

  • Currently taking psychotropic medications for ADHD, other mental illness, or medications for cancer
  • History of epilepsy or seizure disorders
  • History of migraines or other neurological syndromes
  • History of AIDS (due to potential cognitive deficits)
  • History of head trauma or cognitive impairments
  • Personal experiences consistent with symptoms of psychosis (e.g., hallucinations, delusions of control or special powers)
  • History of skull defects (e.g., holes bored into the skull or known cranial fissures)
  • Metal implants in the head or under the scalp
  • Does not meet fMRI safety screening criteria (e.g., metal implants in the body, permanent jewelry, tattoos on the head or neck)
  • Uses an intrauterine device (IUD) for birth control and cannot provide documentation to verify MRI safety
  • Pregnancy (self-reported; no pregnancy test administered)
  • Weight over 440 lbs (scanner weight limit)
  • Presence of pacemakers

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Podstawowa nauka
  • Przydział: Randomizowane
  • Model interwencyjny: Zadanie krzyżowe
  • Maskowanie: Pojedynczy

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Aktywny komparator: dACC 20Hz Active then Sham; Comparison frequency Active then Sham
Participants in this arm receive temporal interference (TI) electrical stimulation targeting the dorsal anterior cingulate cortex using two pairs of carbon fiber electrodes in the following order: 20 Hz TI Active, 20 Hz TI Sham, selected comparison frequency TI Active, then selected comparison frequency TI Sham. The comparison frequency will be within the 1-100 Hz range.
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC 20 Hz TI Active condition, one channel will deliver 2000 Hz and the other 2020 Hz, producing a 20 Hz beat frequency targeting the dorsal anterior cingulate cortex. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Same setup as the dACC 20 Hz TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC comparison frequency TI Active condition, stimulation will be delivered using a selected beat frequency in the 1-100 Hz range. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Same setup as the dACC comparison frequency TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Aktywny komparator: dACC 20Hz Sham then Active; Comparison Frequency Sham then Active
Participants in this arm receive temporal interference (TI) electrical stimulation targeting the dorsal anterior cingulate cortex using scalp electrodes. The stimulation order is: 20 Hz TI Sham, 20 Hz TI Active, selected comparison frequency TI Sham, then selected comparison frequency TI Active. The comparison frequency will be in the 1-100 Hz range.
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC 20 Hz TI Active condition, one channel will deliver 2000 Hz and the other 2020 Hz, producing a 20 Hz beat frequency targeting the dorsal anterior cingulate cortex. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Same setup as the dACC 20 Hz TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC comparison frequency TI Active condition, stimulation will be delivered using a selected beat frequency in the 1-100 Hz range. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Same setup as the dACC comparison frequency TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Aktywny komparator: dACC Comparison Frequency Sham then Active; 20Hz Sham then Active
Participants in this arm receive temporal interference (TI) electrical stimulation targeting the dorsal anterior cingulate cortex using scalp electrodes. The stimulation order is: selected comparison frequency TI Sham, selected comparison frequency TI Active, 20 Hz TI Sham, then 20 Hz TI Active. The comparison frequency will be in the 1-100 Hz range.
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC 20 Hz TI Active condition, one channel will deliver 2000 Hz and the other 2020 Hz, producing a 20 Hz beat frequency targeting the dorsal anterior cingulate cortex. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Same setup as the dACC 20 Hz TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC comparison frequency TI Active condition, stimulation will be delivered using a selected beat frequency in the 1-100 Hz range. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Same setup as the dACC comparison frequency TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Aktywny komparator: dACC Comparison Frequency Active then Sham; 20Hz Active then Sham
Participants in this arm receive temporal interference (TI) electrical stimulation targeting the dorsal anterior cingulate cortex using scalp electrodes. The stimulation order is: selected comparison frequency TI Active, selected comparison frequency TI Sham, 20 Hz TI Active, then 20 Hz TI Sham. The comparison frequency will be in the 1-100 Hz range.
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC 20 Hz TI Active condition, one channel will deliver 2000 Hz and the other 2020 Hz, producing a 20 Hz beat frequency targeting the dorsal anterior cingulate cortex. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Same setup as the dACC 20 Hz TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC comparison frequency TI Active condition, stimulation will be delivered using a selected beat frequency in the 1-100 Hz range. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI
Same setup as the dACC comparison frequency TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Inne nazwy:
  • Neurostymulacja elektryczna TI
  • Neurostymulacja TI

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Change in brain activity in the dorsal anterior cingulate cortex during 20 Hz versus selected comparison frequency temporal interference stimulation
Ramy czasowe: During fMRI scan on study day (approximately 60 minutes)
Brain activity in the dorsal anterior cingulate cortex will be measured using functional magnetic resonance imaging (fMRI) during temporal interference (TI) stimulation at 20 Hz compared to a selected comparison beat frequency. The comparison frequency will be in the 1-100 Hz range. Activity will be reported as the percent change in blood-oxygen-level-dependent (BOLD) signal, which reflects changes in neural activity. Higher BOLD values indicate stronger brain activation.
During fMRI scan on study day (approximately 60 minutes)

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Change in brain activity in the dorsal anterior cingulate cortex during active versus sham stimulation at 20 Hz
Ramy czasowe: During fMRI scan on study day (approximately 60 minutes)
Brain activity in the dorsal anterior cingulate cortex will be measured using fMRI during active versus sham temporal interference stimulation at a 20 Hz beat frequency. Activity will be reported as the percent change in blood-oxygen-level-dependent (BOLD) signal.
During fMRI scan on study day (approximately 60 minutes)
Change in brain activity in the dorsal anterior cingulate cortex during active versus sham stimulation at the selected comparison frequency
Ramy czasowe: During fMRI scan on study day (approximately 60 minutes)
Brain activity in the dorsal anterior cingulate cortex will be measured using fMRI during active versus sham temporal interference stimulation at the selected comparison beat frequency. The comparison frequency will be within the 1-100 Hz range. Activity will be reported as the percent change in blood-oxygen-level-dependent (BOLD) signal.
During fMRI scan on study day (approximately 60 minutes)
Change in brain connectivity between the dorsal anterior cingulate cortex and other brain regions during temporal interference stimulation
Ramy czasowe: During fMRI scan on study day (approximately 60 minutes)
Functional connectivity between the dorsal anterior cingulate cortex and other brain regions will be measured using fMRI-based analyses during active versus sham temporal interference stimulation. Higher correlation values indicate stronger communication between brain regions. The primary test statistic will be the whole-brain psychophysiological interaction (PPI) between dorsal anterior cingulate cortex BOLD activity and stimulation condition.
During fMRI scan on study day (approximately 60 minutes)

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Główny śledczy: Joshua W Brown, PhD, Indiana University, Bloomington

Publikacje i pomocne linki

Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

16 lipca 2026

Zakończenie podstawowe (Szacowany)

30 września 2026

Ukończenie studiów (Szacowany)

30 września 2026

Daty rejestracji na studia

Pierwszy przesłany

11 maja 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

11 maja 2026

Pierwszy wysłany (Rzeczywisty)

19 maja 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

11 września 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

8 września 2026

Ostatnia weryfikacja

1 maja 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • 26941, Study 1.3
  • 1R21MH140210-01 (Grant/umowa NIH USA)

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Tak

produkt wyprodukowany i wyeksportowany z USA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj