Temporal Interference Methods for Non-invasive Deep Brain Stimulation, Study 1.3

8 de setembro de 2026 atualizado por: Joshua Brown, PHD, Indiana University

Temporal Interference Methods for Non-invasive Deep Brain Stimulation

This grant aims to develop a line of research using temporal interference (TI) electrical neurostimulation technology to understand the causal role of deep brain structures in cognition. In the short term, the investigators aim to validate and characterize the effects of TI on brain activity as measured by fMRI and demonstrate its ability to focally stimulate deep brain regions without affecting overlying cortex. In the longer term, investigators aim to use these data to resolve longstanding debates about the function of deeper brain regions and lay the foundation for future clinical applications of TI for treating addiction, Obsessive-Compulsive Disorder (OCD), Parkinson's disease, and other disorders involving deep brain dysfunction. The grant supports 2 distinct aims, each of which will be evaluated through a series of independent studies.

Visão geral do estudo

Descrição detalhada

Through the grant's duration, the investigators hypothesize that temporal interference (TI) electrical neurostimulation will be well tolerated and effective at focally manipulating deep brain activity as measured by functional MRI (fMRI) BOLD signals. The investigators will investigate whether TI stimulation can increase BOLD activity in targeted deep brain regions including the nucleus accumbens (NAcc) and dorsal anterior cingulate cortex (dACC), and whether this stimulation can influence cognitive functions controlled by these regions. TI works by applying alternating currents of slightly different frequencies through multiple electrode pairs, creating an interference pattern that can stimulate deep brain regions without significantly affecting superficial cortical areas. This method is similar to traditional transcranial direct current stimulation (tDCS), however TI can stimulate deeper brain structures that tDCS cannot reach effectively. The study is broken up into two main aims with multiple sub-studies. In Aim 1, the investigators will characterize the effects of TI on fMRI BOLD signals, test different beat frequencies, and compare TI effects in the nucleus accumbens versus dorsal anterior cingulate cortex. In Aim 2, the investigators will apply TI to the dorsal anterior cingulate cortex to test causal theories about its role in cognitive control, conflict monitoring, risk avoidance, and foraging behavior using established cognitive tasks while subjects undergo fMRI scanning.

Study 1.3 (Aim 1, Study 1.3) will test whether TI can focally modulate activity in the dorsal anterior cingulate cortex, around MNI coordinates 0, 30, 30, as measured by fMRI BOLD signal. Healthy subjects (n=30) will complete a single study visit during which they will undergo fMRI while receiving TI stimulation through carbon fiber electrodes attached to the scalp with conductive gel. Electrode placement may vary by participant to optimize dACC targeting using individualized finite element modeling.

Participants will receive active and sham TI stimulation at a selected beat frequency potentially including 5 Hz, 30 Hz, 40 Hz, or another frequency in the 1-100 Hz range. Stimulation will follow an on/off sequence of 2 minutes on, 2 minutes off, 2 minutes on, and 2 minutes off, with 30-second ramp up and ramp down periods beginning at the start of each 2-minute stimulation period. Study 1.3 will also examine whether increased stimulation intensity improves modulation of BOLD activity in the dACC. Stimulation may be delivered up to ±5 mA per channel, corresponding to 10 mA peak-to-peak, with the second stimulation channel linearly scaled based on individualized modeling to maintain optimal targeting. Active and sham stimulation blocks will be counterbalanced across subjects.

Tipo de estudo

Intervencional

Inscrição (Estimado)

30

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

  • Nome: Joshua W Brown, PhD
  • Número de telefone: 812-855-9282
  • E-mail: cclab@iu.edu

Estude backup de contato

  • Nome: Irene Jang, BS
  • Número de telefone: 812-856-1846
  • E-mail: cclabmgr@iu.edu

Locais de estudo

    • Indiana
      • Bloomington, Indiana, Estados Unidos, 47408
        • Recrutamento
        • Indiana University Bloomington, Imaging Research Facility
        • Contato:
          • Josh W Brown, PhD
          • Número de telefone: 812-856-1846
          • E-mail: cclab@iu.edu
        • Contato:
          • Irene Jang, BS
          • Número de telefone: (812) 856-1846
          • E-mail: cclabmgr@iu.edu

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto

Aceita Voluntários Saudáveis

Sim

Descrição

Inclusion Criteria:

  • Between the ages of 18 and 50
  • Must have at least a 6th grade education
  • Ability to speak and read English for all phases

Exclusion Criteria:

  • Currently taking psychotropic medications for ADHD, other mental illness, or medications for cancer
  • History of epilepsy or seizure disorders
  • History of migraines or other neurological syndromes
  • History of AIDS (due to potential cognitive deficits)
  • History of head trauma or cognitive impairments
  • Personal experiences consistent with symptoms of psychosis (e.g., hallucinations, delusions of control or special powers)
  • History of skull defects (e.g., holes bored into the skull or known cranial fissures)
  • Metal implants in the head or under the scalp
  • Does not meet fMRI safety screening criteria (e.g., metal implants in the body, permanent jewelry, tattoos on the head or neck)
  • Uses an intrauterine device (IUD) for birth control and cannot provide documentation to verify MRI safety
  • Pregnancy (self-reported; no pregnancy test administered)
  • Weight over 440 lbs (scanner weight limit)
  • Presence of pacemakers

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Ciência básica
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição cruzada
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: dACC 20Hz Active then Sham; Comparison frequency Active then Sham
Participants in this arm receive temporal interference (TI) electrical stimulation targeting the dorsal anterior cingulate cortex using two pairs of carbon fiber electrodes in the following order: 20 Hz TI Active, 20 Hz TI Sham, selected comparison frequency TI Active, then selected comparison frequency TI Sham. The comparison frequency will be within the 1-100 Hz range.
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC 20 Hz TI Active condition, one channel will deliver 2000 Hz and the other 2020 Hz, producing a 20 Hz beat frequency targeting the dorsal anterior cingulate cortex. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Same setup as the dACC 20 Hz TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC comparison frequency TI Active condition, stimulation will be delivered using a selected beat frequency in the 1-100 Hz range. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Same setup as the dACC comparison frequency TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Comparador Ativo: dACC 20Hz Sham then Active; Comparison Frequency Sham then Active
Participants in this arm receive temporal interference (TI) electrical stimulation targeting the dorsal anterior cingulate cortex using scalp electrodes. The stimulation order is: 20 Hz TI Sham, 20 Hz TI Active, selected comparison frequency TI Sham, then selected comparison frequency TI Active. The comparison frequency will be in the 1-100 Hz range.
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC 20 Hz TI Active condition, one channel will deliver 2000 Hz and the other 2020 Hz, producing a 20 Hz beat frequency targeting the dorsal anterior cingulate cortex. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Same setup as the dACC 20 Hz TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC comparison frequency TI Active condition, stimulation will be delivered using a selected beat frequency in the 1-100 Hz range. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Same setup as the dACC comparison frequency TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Comparador Ativo: dACC Comparison Frequency Sham then Active; 20Hz Sham then Active
Participants in this arm receive temporal interference (TI) electrical stimulation targeting the dorsal anterior cingulate cortex using scalp electrodes. The stimulation order is: selected comparison frequency TI Sham, selected comparison frequency TI Active, 20 Hz TI Sham, then 20 Hz TI Active. The comparison frequency will be in the 1-100 Hz range.
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC 20 Hz TI Active condition, one channel will deliver 2000 Hz and the other 2020 Hz, producing a 20 Hz beat frequency targeting the dorsal anterior cingulate cortex. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Same setup as the dACC 20 Hz TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC comparison frequency TI Active condition, stimulation will be delivered using a selected beat frequency in the 1-100 Hz range. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Same setup as the dACC comparison frequency TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Comparador Ativo: dACC Comparison Frequency Active then Sham; 20Hz Active then Sham
Participants in this arm receive temporal interference (TI) electrical stimulation targeting the dorsal anterior cingulate cortex using scalp electrodes. The stimulation order is: selected comparison frequency TI Active, selected comparison frequency TI Sham, 20 Hz TI Active, then 20 Hz TI Sham. The comparison frequency will be in the 1-100 Hz range.
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC 20 Hz TI Active condition, one channel will deliver 2000 Hz and the other 2020 Hz, producing a 20 Hz beat frequency targeting the dorsal anterior cingulate cortex. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Same setup as the dACC 20 Hz TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Non-invasive electrical brain stimulation delivered through two sets of scalp electrodes using alternating current frequencies at up to ±5 mA per channel, corresponding to 10 mA peak-to-peak. For the dACC comparison frequency TI Active condition, stimulation will be delivered using a selected beat frequency in the 1-100 Hz range. Stimulation is administered in 2-minute on / 2-minute off cycles with a 30-second ramp up and ramp down beginning at the start of each 2-minute period.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI
Same setup as the dACC comparison frequency TI Active condition, except that stimulation immediately ramps down after reaching the target intensity following ramp up, producing a sham condition.
Outros nomes:
  • Neuroestimulação Elétrica TI
  • Neuroestimulação TI

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Change in brain activity in the dorsal anterior cingulate cortex during 20 Hz versus selected comparison frequency temporal interference stimulation
Prazo: During fMRI scan on study day (approximately 60 minutes)
Brain activity in the dorsal anterior cingulate cortex will be measured using functional magnetic resonance imaging (fMRI) during temporal interference (TI) stimulation at 20 Hz compared to a selected comparison beat frequency. The comparison frequency will be in the 1-100 Hz range. Activity will be reported as the percent change in blood-oxygen-level-dependent (BOLD) signal, which reflects changes in neural activity. Higher BOLD values indicate stronger brain activation.
During fMRI scan on study day (approximately 60 minutes)

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Change in brain activity in the dorsal anterior cingulate cortex during active versus sham stimulation at 20 Hz
Prazo: During fMRI scan on study day (approximately 60 minutes)
Brain activity in the dorsal anterior cingulate cortex will be measured using fMRI during active versus sham temporal interference stimulation at a 20 Hz beat frequency. Activity will be reported as the percent change in blood-oxygen-level-dependent (BOLD) signal.
During fMRI scan on study day (approximately 60 minutes)
Change in brain activity in the dorsal anterior cingulate cortex during active versus sham stimulation at the selected comparison frequency
Prazo: During fMRI scan on study day (approximately 60 minutes)
Brain activity in the dorsal anterior cingulate cortex will be measured using fMRI during active versus sham temporal interference stimulation at the selected comparison beat frequency. The comparison frequency will be within the 1-100 Hz range. Activity will be reported as the percent change in blood-oxygen-level-dependent (BOLD) signal.
During fMRI scan on study day (approximately 60 minutes)
Change in brain connectivity between the dorsal anterior cingulate cortex and other brain regions during temporal interference stimulation
Prazo: During fMRI scan on study day (approximately 60 minutes)
Functional connectivity between the dorsal anterior cingulate cortex and other brain regions will be measured using fMRI-based analyses during active versus sham temporal interference stimulation. Higher correlation values indicate stronger communication between brain regions. The primary test statistic will be the whole-brain psychophysiological interaction (PPI) between dorsal anterior cingulate cortex BOLD activity and stimulation condition.
During fMRI scan on study day (approximately 60 minutes)

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: Joshua W Brown, PhD, Indiana University, Bloomington

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

16 de julho de 2026

Conclusão Primária (Estimado)

30 de setembro de 2026

Conclusão do estudo (Estimado)

30 de setembro de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

11 de maio de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

11 de maio de 2026

Primeira postagem (Real)

19 de maio de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

11 de setembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

8 de setembro de 2026

Última verificação

1 de maio de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 26941, Study 1.3
  • 1R21MH140210-01 (Concessão/Contrato do NIH dos EUA)

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .