Fluorescent Probe for Assessment of Renal Elimination (FLARE)
Przegląd badań
Status
Szczegółowy opis
The majority of acutely ill patients exhibit changes in renal function due to inflammation, increased solute generation, and iatrogenic factors such as fluid resuscitation and vasopressors. The pharmacokinetics of renally eliminated medications (eg. levetiracetam, cefepime, vancomycin) are frequently affected by inflammatory processes despite normal estimations in creatinine clearance resulting in suboptimal serum drug concentrations and therapeutic failure. Despite the prevalence of fluctuations in renal function in acute illness, real-time assessment is limited to monitoring of serum biomarkers such as creatinine and cystatin C, as well as urine output, which typically lag behind important changes in function. Furthermore, use of creatinine clearance equations based on anthropomorphic data correlates poorly with actual renal function, potentially misleading clinicians as to the progression of disease and the need for dose adjustment of important medications in this vulnerable population.
Limitations of current approaches for evaluating renal function in the acutely ill Estimation of GFR or creatinine clearance can be accomplished by numerous equations, the majority of which have been validated in non-critically ill adults, usually with a relatively high percent of patients with chronic kidney disease. These equations are often not accurate in patients with acutely worsening renal function. Likewise, while these equations are helpful for categorizing renal function and assessing appropriate medication dosing in otherwise healthy, ambulatory patients. Under-prediction of creatinine clearance values leads clinicians to consistently under-dose critical medications such as beta-lactam antibiotics, vancomycin, or antiseizure medications such as levetiracetam.
Proactive measurement of creatinine clearance can provide a more accurate depiction of GFR but is fraught with complications. Iohexol serum concentrations correlate well with GFR, but requires intravenous administration of iohexol, which has a small risk of infusion reaction and hypersensitivity, and serial blood samples. Measured urine creatinine clearance is also feasible but inconvenient in most hospitalized patients. mClCr requires bladder catheterization for accurate urine volume, consistent storage on ice for the duration of collection (between 8 and 24 hours), and prompt delivery of the large volume container to the local laboratory for creatinine analysis. Each of these criteria introduce variability into the measurement and are often unnoticed or undocumented, introducing inaccuracy into the mClCr values. The lack of a real-time, accurate assessment of creatinine clearance in the acutely ill population is a gap in practice and represents a resolvable problem in the process of individualized and precision dosing of medications in this vulnerable and high-risk population.
This study represents an important innovation in advancing the understanding of fluctuations in renal function during acute illness. The current study will validate the safety of transdermal GFR monitoring to provide real-time measurement of renal function in patients with stable renal function. Further, the reliability of transdermal GFR monitoring will be compared to current standards of renal function assessment. The results of this study will advance the field by validating the use of a real-time physiologic assessment of GFR rather than using labor intensive, invasive tests that may lag behind current renal function. Numerous important gaps remain with this new technology, including use primarily in the ambulatory, stable renal function populations. Thus, this study is potentially the first step in evaluating renal function across the acute care continuum.
Typ studiów
Zapisy (Szacowany)
Faza
- Faza 4
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: Aaron Cook, PharmD
- Numer telefonu: 18592578444
- E-mail: amcook0@uky.edu
Lokalizacje studiów
-
-
Kentucky
-
Lexington, Kentucky, Stany Zjednoczone, 40536
- UKHealthCare/University of Kentucky
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- 18-65 years old
- critically ill or acutely ill hospitalized patients admitted to the intensive care unit
- Stable/normal renal function
Exclusion Criteria:
- Prisoners
- Pregnant women
- Laboratory evidence of unstable kidney function (KDIGO AKI stage 1-3--This includes subjects with Scr > 1.5x baseline)
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Diagnostyczny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: MediBeacon Transdermal Glomerular Filtration Rate (GFR) Monitoring
|
IV push of relmapirazin (Lumitrace) prior to use of the tGFR device
Small IV push bolus of iohexol as a probe for renal function will be administered prior to use of the tGFR device.
The tGFR monitor will be applied to the patient after relmapirazin bolus for measurement of GFR.
8-hour urine creatinine clearance collection will be performed during the study period to compare to tGFR & other renal function measures.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Transdermal Glomerular Filtration Rate (tGFR) Monitoring Accuracy
Ramy czasowe: 8 Hours
|
Accuracy of transdermal glomerular filtration rate (GFR) monitoring compared with measured urine creatinine clearance.
|
8 Hours
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Relmapirazin Elimination Half-Life
Ramy czasowe: 12 hours
|
Elimination half-life of Relmapirazin calculated from serial serum concentration measurements obtained over 12 hours following intravenous administration.
|
12 hours
|
|
Iohexol Elimination Half-Life
Ramy czasowe: 12 hours
|
Elimination half-life of Iohexol calculated from serial serum concentration measurements obtained over 12 hours following intravenous administration.
|
12 hours
|
Współpracownicy i badacze
Sponsor
Śledczy
- Główny śledczy: Aaron M Cook, PharmD, University of Kentucky College of Pharmacy, Department of Pharmacy Practice & Science
- Dyrektor Studium: Juan-Carlos Aycinena, MD, University of Kentucky College of Medicine, Department of Nephrology
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Szacowany)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Dodatkowe istotne warunki MeSH
- Procesy patologiczne
- Atrybuty choroby
- Stany patologiczne, oznaki i objawy
- Śmiertelna choroba
- Organiczne chemikalia
- Węglowodory
- Węglowodory, cykliczne
- Kwasy karboksylowe
- Węglowodory, aromatyczne
- Pochodne benzenu
- Kwasy, karbocykliczne
- Benzoates
- Kwasy triiodobenzoinowe
- Iodobenzoates
- Iohexol
- relmapirazyna
Inne numery identyfikacyjne badania
- 105008
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .