Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Ultrasound Guided Leadless Pacemaker Implantation

23 października 2026 zaktualizowane przez: China National Center for Cardiovascular Diseases

A Study on the Feasibility of a Novel Guidance Method for Leadless Pacemaker Implantation

The leadless pacemaker is a novel pacing technology that has emerged in recent years. Compared with conventional lead pacemakers, its design avoids many complications associated with leads and pacemaker pockets, including lead fracture, pocket infection, and venous access stenosis. Because of its small size and the absence of a pacemaker pocket or pacing lead, the leadless pacemaker is particularly suitable for patients with contraindications to conventional pacemaker implantation, including patients undergoing hemodialysis, patients with recurrent pocket infection, and patients without suitable vascular access.

Currently, leadless pacemaker implantation is performed primarily under fluoroscopic guidance. Fluoroscopy provides real-time intraoperative anatomical localization information but places high demands on the operator's technical skills and the precise intraoperative positioning of the pacemaker. However, procedures performed under fluoroscopic guidance require dedicated procedure rooms and radiation-generating equipment. Such large-scale equipment is expensive, and it requires special protective measures that make the surrounding walls, doors and windows meet the protection standards, so as not to cause harm to the surrounding environment and personnel. When procedures are performed under fluoroscopic guidance in dedicated catheterization laboratories, both operators and patients are exposed to potential health risks, and fluoroscopy-guided procedures are contraindicated in some pregnant women. In addition, X-ray imaging remains two-dimensional, and visualization may be inadequate in some patients because of individual anatomical variation, potentially increasing procedural difficulty. Therefore, exploring a radiation-free, real-time, and accurate guidance method has become a key approach to improving the success rate and safety of leadless pacemaker implantation.

Przegląd badań

Szczegółowy opis

Currently, research on leadless pacemakers has primarily focused on device optimization and long-term postoperative follow-up assessment, whereas relatively few studies have investigated imaging innovations related to procedural techniques and methods. This study is designed to preliminarily explore the feasibility and safety of TTE-guided leadless pacemaker implantation and systematically evaluate the value of TTE in leadless pacemaker implantation, thereby providing a novel and effective procedural approach to leadless pacemaker implantation. This study may also facilitate the further development of leadless pacemaker implantation technology and provide patients with safer and more convenient treatment options

This study consists of two stages. Stage 1: to establish a standardized operating procedure for TTE-guided Micra leadless pacemaker implantation through combined echocardiographic and fluoroscopic guidance and mutual verification. Stage 2: to conduct a multicenter, prospective, randomized controlled study comparing the acute procedural success rate and complication rate between TTE-guided and conventional fluoroscopy-guided leadless pacemaker implantation to evaluate acute safety and effectiveness and provide high-quality evidence to support the subsequent clinical adoption of this technique.

Stage 1: Exploration of the Standard Operating Procedure Patients who meet the eligibility criteria will undergo the procedure according to the standard operating procedure under fluoroscopic guidance or using TTE guidance with fluoroscopic verification to explore the key techniques of TTE guidance, with intraoperative data collected.

Stage 2: Multicenter Randomized Controlled Study Phase On the basis of sufficient procedural experience accumulated and the establishment of a standard operating procedure during Stage 1, a multicenter, prospective, randomized controlled study will be conducted to compare TTE guidance with conventional fluoroscopic guidance for leadless pacemaker implantation in terms of procedural success rate, procedure duration, pacing parameters, and complication rate, and to evaluate differences in procedural success rate and complication rate between the two guidance methods. Operators participating in Stage 2 shall have experience with at least 5 cases of TTE-guided Micra leadless pacemaker implantation.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

288

Faza

  • Nie dotyczy

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat i starsze (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  1. Age ≥ 18 years, regardless of sex;
  2. Patients with indications for permanent pacemaker implantation who are expected to have a low ventricular pacing burden, or patients who are expected to have a high ventricular pacing burden (≥40%) but have normal cardiac function, including complete or intermittent high-grade atrioventricular block, intermittent sinus arrest, and persistent sinus bradycardia (meeting the indications for implantation specified in the Chinese expert consensus on leadless pacemaker (2022)), particularly those with the following conditions: renal insufficiency, contraindications to X-ray radiation exposure, or potential adverse consequences from X-ray radiation exposure, as these patients are most likely to directly benefit from the ultrasound-guided procedure;
  3. Patients who have signed informed consent form.

Exclusion Criteria:

  1. Those with significant chest wall deformity (e.g., severe pectus carinatum or barrel chest) or severe obesity affecting transthoracic echocardiography image quality;
  2. Those with severe anatomical abnormalities of the right heart (e.g., an excessively small right ventricle, severe tricuspid regurgitation, Ebstein anomaly, or arrhythmogenic right ventricular cardiomyopathy);
  3. Those with presence of any lead from an existing pacemaker, implantable cardioverter-defibrillator (ICD), or cardiac resynchronization therapy (CRT) device;
  4. Those with presence of a mechanical tricuspid valve prosthesis, inferior vena cava filter, or left ventricular assist device (LVAD);
  5. Those with known intolerance to nickel-titanium alloy (nitinol);
  6. Those with concurrent active infection (e.g., bacteremia or infective endocarditis) or uncontrolled systemic infection;
  7. Those with life expectancy < 1 year;
  8. Those who have recently undergone another interventional cardiac procedure that may interfere with the study results;
  9. Those who are unable to complete study follow-up, such as cognitive impairment or extremely poor adherence.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: Transthoracic echocardiography-guided group

Use transthoracic echocardiography to guide the implantation of a leadless pacemaker

  1. Preoperative Preparation:

    Perform preoperative assessment using TTE to evaluate cardiac chamber anatomy and ultrasound image quality.

    Individually adjust the ultrasound system settings according to patient characteristics and record key anatomical landmarks.

  2. Intraoperative Procedure:

Use real-time TTE to guide the pacemaker delivery catheter through the right atrium to the right ventricle.

Observe the catheter trajectory and identify the target region. After confirming electrode contact, complete pacemaker fixation and record the imaging findings in real time.

Commercially available leadless pacemaker system implanted in all study participants.

Aktywny komparator: Conventional fluoroscopy-guided group

Use conventional fluoroscopy to guide the implantation of leadless pacemaker

Commercially available leadless pacemaker system implanted in all study participants.

Leadless pacemaker implantation is performed under fluoroscopic guidance in accordance with current standard clinical practice.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Percentage of participants with successful Micra leadless pacemaker implantation
Ramy czasowe: During Procedure

Successful implantation is defined as successful deployment of the Micra leadless pacemaker during the procedure with a pacing threshold < 2.5 V @ 0.24 ms within 15 minutes before cutting the tether.

During Procedure

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
The device-related serious adverse events occurring during the perioperative period
Ramy czasowe: intraoperatively or before discharge

Defined as: death; prolongation of length of hospital stay by ≥48 hours; pacemaker malfunction (ventricular pacing threshold > 5 V/0.24 ms or sensed R-wave amplitude < 2 mV); pacemaker dislodgement; cardiac tamponade; rehospitalization for cardiac causes; vascular complication requiring surgical intervention; or system revision. A clinical events committee comprising independent physicians will review and adjudicate all system- and procedure-related events to determine their relatedness and whether any related event meets any criteria for a major complication. System revision includes any invasive modification of the device (e.g., replacement, repositioning, or removal) or programming of the device to an off state (OOO mode).

intraoperatively or before discharge

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

20 października 2026

Zakończenie podstawowe (Szacowany)

20 kwietnia 2028

Ukończenie studiów (Szacowany)

20 lipca 2028

Daty rejestracji na studia

Pierwszy przesłany

29 września 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

29 września 2026

Pierwszy wysłany (Rzeczywisty)

5 października 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

27 października 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

23 października 2026

Ostatnia weryfikacja

1 września 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • 2026-0026-01

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Tak

produkt wyprodukowany i wyeksportowany z USA

Tak

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj