- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT02016937
Mother Lactation in The Postpartum Period (lactation)
Effects of Different Anesthesia Protocols on Mother Lactation in The Postpartum Period
Visão geral do estudo
Status
Condições
Descrição detalhada
Patients were randomly divided into 4 groups: group G (general anesthesia for Caesarean section, n=21), group S (spinal anesthesia for Caesarean section, n=21), group E (epidural anesthesia for Caesarean section, n=21), group V (normal vaginal birth without anesthesia, n=21). Blood sample of 3 mililiters was taken from all patients 2,5 hours before procedure and oxytocin and prolactin levels in this blood samples were determined. No patient received premedication. Group G (general anesthesia for Caesarean section) received preoxygenation with 100% oxygen for 3-5 minutes before intubation. In order to let fetus minimally affected by the anesthetic agents, induction was performed after the disinfection and covering up of surgery area. Induction was performed with propofol (2 mg/ kg) and rocuronium (0,6 mg/kg). After onset of neuromuscular block, patients were intubated with compression maneuver of cricoid cartilage. Controlled ventilation was provided with anesthesia machine Datex Ohmeda S/5 Avance with tidal volume of 8-10 ml/kg, respiration frequency of 10-12 min. Anesthesia was maintained with oxygen (50%) , air (50%), sevoflurane of 1 MAC. When necessary rocuronium 0,15 mg/kg was administered. After delivery of the newborn, fentanyl 1-1,5 mcg/ kg was administered.
Patients in group S (spinal anesthesia for Caesarean section) received 750-1000 mL of 0,9% NaCI solution (10-15 mL/kg) as infusion in 20-30 minutes. Under strict aseptic precautions a 25G Quincke spinal needle was introduced into L3-L4 or L4-L5 intervertebral space in midline approach in sitting posture, and, after confirming free flow of CSF, predetermined 10-11 mg of drug solution (hypertonic bupivacaine 0,5%) was injected. We let the operation begin when sensory and motor blockade were verified. Oxygen of 100% (3 L. min) was administered throughout the operation via nasal cannula.
Patients in group E (epidural anesthesia for Caesarean section) received 750-1000 mL of 0,9% NaCI solution (10-15 mL/kg) as infusion in 20-30 minutes. We conducted epidural anesthesia with 18-gauge Tuohy needle at L3-L4 or L4-L5 epidural space by midline approach at sitting position. 3 -5 minutes after injection of 3 ml lidocaine as test-dose, when the patient has no sign of subarachnoid injection like prickling in lower extremities or of intravascular injection like nausea, vomiting, tachicardia, tinnitus, a 20-gauge epidural catheter was inserted to cephalad. We injected 10 ml of 0.5% bupivacaine via epidural catheter. We let the operation begin when sensory and motor blockade were verified. Oxygen of 100% (3 L. min) was administered throughout the operation via nasal cannula.
Patients in all 3 groups were monitorised in the operation room with a monitor of Datex-Ohmeda and electrocardiogram (ECG), systolic blood pressure (SBP), diastolic blood pressure (DBP), mean blood pressure (MBP), heart rate (HR), peripheral oxygen saturation (SPO2) were recorded. Efedrin 5-10 mg and/or atropin 0,5 mg was administered when significant hypotension and bradicardia occurred. After delivery of the newborn 30 IU of oxytocin in a 1000cc solution of 0,9% NaCI was infused and if patient was not hypertensive, methylergonovine of 0,2 mg was administered intramuscular.
Patients in group V (spontaneous vaginal birth without anesthesia) were spectated by gynecologists in the Clinic of Gynecology and Obstetrics during the delivery. They received no anesthesia.
In all groups blood samples were taken at the 24th hour after delivery and oxytocin and prolactin levels were measured. Plasma of blood samples taken before and after delivery were stored at a temperature of -80°C. Prolactin levels were determined with chemiluminescense immunoassay technique Cobas e 601 (Roche® Diagnostics, Mannheim, Germany) using a commercial kit (Roche®). Oxytocin levels were determined with a commercial ELISA kit (Cusabio Biotech CO. Ltd). By all patients onset time of lactation was recorded.
Tipo de estudo
Inscrição (Real)
Contactos e Locais
Locais de estudo
-
-
-
Duzce, Peru, 81620
- Anesthesiology Department
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- elective caesarian section
- normal vaginal delivery.
- between 18-40 years old
- risk of American society of anesthesiology grade-2
Exclusion criteria :
- Non-elective cases, plural pregnancies,
- Preterm pregnancies,
- Fetal anomalies,
- Retardation of fetal development,
- Newborns with birthweight under 2500 grams,
- Infants with risk of aspiration of meconium or amnios,
- Pathologies affecting acid-base balance,
- Diabetes mellitus,
- Hypertension,
- Antepartum hemorrhage,
- COPD (chronic obstructive pulmonary disease),
- Rhesus incompatibility,
- Obstetric complications like congenital malformations,
- History of malignant hypertermia,
- Morbid obesity, opioid sensitivity,
- Alcohol or drug addiction,
- Diseases of coronary arteria,
- Congestive heart failure,
- Serious anemia,
- History of liver or kidney diseases,
- Hypovolemia, hypotension,
- Systemic inflammatory response syndrome,
- Sepsis,
- History of allergic reactions to drugs used in the study,
- History of drugs affecting lactation.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
|---|
|
group g
general anesthesia, n: 21
|
|
group S
spinal anesthesia, n: 21
|
|
group E
epidural anesthesia, n: 21
|
|
group V
vaginal birth, without anesthesia, n: 21
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
onset time of lactation of mothers
Prazo: 24 h
|
By all patients onset time of lactation was recorded postoperatively
|
24 h
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
hormon levels
Prazo: 24 h
|
In all groups blood samples were taken at the 24th hour after delivery and oxytocin and prolactin levels were measured.
Plasma of blood samples taken before and after delivery were stored at a temperature of -80°C.
Prolactin levels were determined with chemiluminescense immunoassay technique Cobas e 601 (Roche® Diagnostics, Mannheim, Germany) using a commercial kit (Roche®).
Oxytocin levels were determined with a commercial ELISA kit (Cusabio Biotech CO. Ltd).
|
24 h
|
Outras medidas de resultado
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Apgar scores
Prazo: 5 min
|
Neonate APGAR Scores 1st and 5th minutes were recorded
|
5 min
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Diretor de estudo: Yavuz Demiraran, Duzce University School of Medicine
Publicações e links úteis
Publicações Gerais
- Volmanen P, Valanne J, Alahuhta S. Breast-feeding problems after epidural analgesia for labour: a retrospective cohort study of pain, obstetrical procedures and breast-feeding practices. Int J Obstet Anesth. 2004 Jan;13(1):25-9. doi: 10.1016/S0959-289X(03)00104-3.
- Baumgarder DJ, Muehl P, Fischer M, Pribbenow B. Effect of labor epidural anesthesia on breast-feeding of healthy full-term newborns delivered vaginally. J Am Board Fam Pract. 2003 Jan-Feb;16(1):7-13. doi: 10.3122/jabfm.16.1.7.
- Uvnas-Moberg K, Widstrom AM, Werner S, Matthiesen AS, Winberg J. Oxytocin and prolactin levels in breast-feeding women. Correlation with milk yield and duration of breast-feeding. Acta Obstet Gynecol Scand. 1990;69(4):301-6. doi: 10.3109/00016349009036151.
Links úteis
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- leylakutlucan
- Duzce University (Outro identificador: Duzce University scientific research projects department)
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .