Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Interactive Power Toothbrush With or Without App vs Manual Toothbrush

8 de dezembro de 2021 atualizado por: Sühan Gürbüz, Gazi University

The Effects of Interactive Powered Toothbrush With Application-assisted on Plaque, Gingivitis and Gingival Abrasion: A Randomized Controlled Clinical Trial.

It has been suggested that interactive power toothbrushes (PTBs), developed in recent years, provide more successful results in plaque control and effective use of brushing time by enabling patient collaboration and self-treatment, thanks to the application features associated with mobile phones. Interactive PTB synchronized with smartphones, including real-time feedback, session length, applications that prevent excessive brushing force, and focus brushing on specific areas with position detection technology, increases the brushing performance by increasing oral hygiene motivation.

Studies report that both power and manual toothbrushes cause gingival abrasion, a localized reversible lesion of the epithelium. While the opinions about the cause of gingival abrasion are not clear yet, the discussions regarding brush strength yet continue. While it is possible to control the interactive PTB force thanks to the mobile application, it is known that these high-speed rotating brushes control plaque effectively, but there is not enough evidence about its effect on gingival abrasion.

The primary purpose of this clinical study is to determine whether interactive PTB with application feature provides an additional benefit on plaque removal efficacy and reduction of gingival inflammation. In addition, this study aims to determine the effect of interactive power toothbrush with application on gingival abrasion by comparing it to interactive PTB without application and manual toothbrush. The study's null hypothesis in terms of gingival abrasion is that interactive PTB do not show a significant difference from other brushing methods.

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Real)

86

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

      • Ankara, Peru, 06490
        • Sühan Gürbüz

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos a 25 anos (Adulto)

Aceita Voluntários Saudáveis

Sim

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • Dental students
  • Diagnosed with gingivitis
  • Clinical measurements: Probing pocket depths ≤3 mm, QHPI-TM ≥ 1.75 and with a bleeding site of at least 40% or more
  • Aged between 18-25
  • Non-smoker
  • No systemic diseases
  • Not undergoing orthodontic treatment
  • No crowding
  • No periodontal treatment in the last three months

Exclusion Criteria:

  • Use of power toothbrush before
  • Use of drugs that may affect the gingival tissues
  • Having mucogingival problems
  • Having carious teeth that require urgent treatment
  • Probing pocket depths ˃ 3mm

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Oral-B Genius® 8000 power toothbrush with Cross Action brush head with smartphone app for 8 weeks
Interactive PTB with Bluetooth® 4.0 connectivity smartphone app with Cross Action brush head using visually position detection feature. A triple pressure control system stops vibration, gives a visual warning, and reduces rotation speed in Daily Cleaning Mode-1.
All the participants were asked to brush with fluoride toothpaste (Pro-Expert Professional Protection- Ipana, Gross-Gerau, Germany) with a pea-sized amount (0.25 g) of the toothbrushes, which were given oral and applied instructions for use, twice a day in the morning and evening. The installation and operation of the toothbrush application (app) on the smartphone was activated in the PTB with the app group
Comparador Ativo: Oral-B Genius® 8000 power toothbrush with CrossAction brush head without smartphone app for 8 weeks
PTB without Bluetooth® 4.0 connectivity without smartphone app with Cross Action brush head without using visually position detection feature triple pressure control system stops vibration, provides visual warning and reduces rotation speed. The group was asked to use PTB with daily cleaning mode 1 and brush head, but without using the Bluetooth app (without using the position detection system).
All the participants were asked to brush with fluoride toothpaste (Pro-Expert Professional Protection- Ipana, Gross-Gerau, Germany) with a pea-sized amount (0.25 g) of the toothbrushes, which were given oral and applied instructions for use, twice a day in the morning and evening. The installation and operation of the toothbrush application (app) on the smartphone were not activated in the PTB without the app group.
Comparador Ativo: Manual toothbrush: Oral B ClinicLine Pro-FlexSoft (Procter&Gamble,Ohio, USA) for 8 weeks
They were instructed to brush according to the Modified Bass technique.
All the participants were asked to brush with fluoride toothpaste (Pro-Expert Professional Protection- Ipana, Gross-Gerau, Germany) with a pea-sized amount (0.25 g) of the toothbrushes, which were given oral and applied instructions for use, twice a day in the morning and evening. They were instructed to brush with the Modified Bass technique.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Turesky modification of the Quigley-Hein Plaque Index (QHPI-TM) index measurement
Prazo: 2 weeks
Tooth surfaces stained with Mira-2 Toneblue® were evaluated with six different scores: Score 0 = No plaque, Score 1 = Plaque stains on the cervical edge of the tooth, Score 2 = A thin, continuous strip of plaque (up to 1 mm) at the cervical edge of the tooth, Score 3 = band of plaque wider than 1 mm but covering less than one-third of the dental crown, Score 4 = Plaque covering at least one-third but less than two-thirds of the dental crown, Score 5 = Plaque covering two-thirds or more of the dental crown.
2 weeks
Turesky modification of the Quigley-Hein Plaque Index (QHPI-TM) index measurement
Prazo: 8 weeks
Tooth surfaces stained with Mira-2 Toneblue® were evaluated with six different scores: Score 0 = No plaque, Score 1 = Plaque stains on the cervical edge of the tooth, Score 2 = A thin, continuous strip of plaque (up to 1 mm) at the cervical edge of the tooth, Score 3 = band of plaque wider than 1 mm but covering less than one-third of the dental crown, Score 4 = Plaque covering at least one-third but less than two-thirds of the dental crown, Score 5 = Plaque covering two-thirds or more of the dental crown.
8 weeks
Bleeding on marginal bleeding index (BOMP) index measurement
Prazo: 2 weeks
The presence/absence and amount of bleeding were graded on a 0-2 scale within 30 seconds of probing by probing the gingival margin at an angle of approximately 60 to the long axis of the tooth (0 = no bleeding, 1 = punctate bleeding, 2 = excessive bleeding).
2 weeks
Bleeding on marginal bleeding index (BOMP) index measurement
Prazo: 8 weeks
The presence/absence and amount of bleeding were graded on a 0-2 scale within 30 seconds of probing by probing the gingival margin at an angle of approximately 60 to the long axis of the tooth (0 = no bleeding, 1 = punctate bleeding, 2 = excessive bleeding).
8 weeks
Staining with Mira-2 Toneblue® to detect the gingival abrasion scores
Prazo: 2 weeks
Blue or purple visible abrasions were classified by measuring with a Williams periodontal probe placed along the long axis of the lesions ("small" if ≤2 mm, "moderate" if ≥3 mm and ≤5 mm, and "large" if >5 mm).
2 weeks
Staining with Mira-2 Toneblue® to detect the gingival abrasion scores
Prazo: 8 weeks
Blue or purple visible abrasions were classified by measuring with a Williams periodontal probe placed along the long axis of the lesions ("small" if ≤2 mm, "moderate" if ≥3 mm and ≤5 mm, and "large" if >5 mm).
8 weeks

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Brushing times
Prazo: 8 weeks
The records in PTB group without-app and MTB were obtained with digital timer. In contrast, these records were obtained at the last appointment of the study; in Group PTB-A, the last brushing time records were sent to the researcher via e-mail by using the integral timer of the toothbrush, which is a feature of the mobile application.
8 weeks
Questionnaire
Prazo: 8 weeks

Questionnaire was applied to the participants including post-brushing pain/tenderness, cleaning capacity, manageability, and willingness to purchase via Visual Analogue Scale.

Subjects were asked to mark a point on a 10 cm long uncalibrated line, with both ends interpreted as negative (left) or positive (right) ends.

8 weeks

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

12 de maio de 2017

Conclusão Primária (Real)

17 de agosto de 2017

Conclusão do estudo (Real)

17 de agosto de 2017

Datas de inscrição no estudo

Enviado pela primeira vez

27 de novembro de 2021

Enviado pela primeira vez que atendeu aos critérios de CQ

27 de novembro de 2021

Primeira postagem (Real)

8 de dezembro de 2021

Atualizações de registro de estudo

Última Atualização Postada (Real)

29 de dezembro de 2021

Última atualização enviada que atendeu aos critérios de controle de qualidade

8 de dezembro de 2021

Última verificação

1 de dezembro de 2021

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 123456 (Innovate UK)

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever