A Clinical Study Used to Estimate Central Venous Pressure Non-invasively Using Occlusion Pressure (CV-PRO)

6 de maio de 2026 atualizado por: Danielle Gottlieb Sen, Le Bonheur Children's Hospital

Non-Invasive Central Venous Pressure Estimation Using Occlusion Pressure: A Novel Approach for Accurate Hemodynamic Monitoring

The purpose of this study is to collect different measurements using a method called peripheral venous pressure (PVP). PVP checks the pressure in the veins in the arms or legs. It can give doctors a good idea of how well the heart is working, similar to another method called central venous pressure (CVP), which doctors use in hospitals. In this study, the research team will measure PVP in people aged 0-17. The researcher hopes that this data will help doctors understand how PVP measurements relate to health outcomes, which could lead to better ways to diagnose and treat patients in the future.

The peripheral venous pressure (PVP) device will be used to non-invasively measure the pressure required to stop blood flow in the forearm, which will indirectly measure the PVP in the forearm. This device is composed of a pressure sensor and a Doppler flow detector that will be connected to a research laptop for data collection. This device will be placed on the forearm.

If you agree to be in this study, the study team will monitor the venous flow rate (the amount of blood moving through the veins over a certain period of time) using a Doppler Flow Detector while applying pressure to the vein with a pressure sensor. This will take place on the forearm.

The internal jugular vein will be identified and recorded using ultrasound imaging and Doppler sensor.

The forearm vein will be identified and marked using ultrasound imaging. Pressure will be applied for 15 seconds, and then stopped and repeated 4 times, making five sets of measurements.

The procedure may be repeated in 2-3 additional sessions during the hospital stay, if necessary.

Your participation in this study will last approximately 30 minutes.

This procedure is for research only and will not affect your regular care. This will occur during your child's stay in the PCICU/PICU. No additional study visits will be required.

The following procedures are being performed for research purposes only:

Copying information such as your medical history from your medical record; Obtaining non-invasive peripheral venous pressure measurements.

Visão geral do estudo

Status

Ainda não está recrutando

Descrição detalhada

Pediatric congestive heart failure (CHF) is a complex, often end-stage condition affecting around 35,000 children annually in the U.S., with 14,000 hospitalizations and a 6.3% in-hospital mortality rate. CHF occurs when the heart can't meet circulatory demands, leading to increased central venous pressure (CVP), which is currently measured invasively.

In outpatient pediatric care, CHF monitoring relies on subjective symptom reporting and potentially inaccurate weight measurements resulting in a 50% misdiagnosis rate. Recent studies indicate a strong correlation between peripheral venous pressure (PVP) and CVP, suggesting that noninvasive PVP measurements, obtained through occlusion pressure, could accurately estimate CVP.

To test this, the researcher developed a proof-of-concept study using ultrasound, Doppler transducers, and pressure sensors to measure occlusion pressure in veins. This data will be calibrated against direct CVP measurements from central lines using linear regression. The goal is to enhance outpatient monitoring for pediatric CHF, improving diagnostic accuracy by integrating inpatient methods into outpatient settings.

This study will push forward the development of an innovation in pediatric outpatient monitoring, aiming to bring the accuracy and precision of inpatient monitoring into the outpatient settings.

Tipo de estudo

Observacional

Inscrição (Estimado)

30

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Filho

Aceita Voluntários Saudáveis

N/D

Método de amostragem

Amostra Não Probabilística

População do estudo

Pediatric patients admitted to the Pediatric Intensive Care Unit (PICU) or the Pediatric Cardiac Intensive Care Unit (PCICU) at Le Bonheur Children's Hospital.

Descrição

Inclusion Criteria:

  • Admitted to PICU or PCICU
  • Provided written informed consent
  • Continuous Central venous pressure monitoring transduced from a standard central venous catheter (not PICC line)

Exclusion Criteria:

  • Glenn and Fontan Patients
  • Heterotaxy Syndrome Patients
  • Inability to consent by guardian/caretaker

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Pediatric Participants Admitted to the ICU with a Central Venous Catheter
All participants in the study admitted to a pediatric ICU with a central venous catheter in place.
Variable CVP Subset
A subset of approximately 5 participants that have varying ranges of central venous pressure throughout their hospitalization.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Mean absolute error (MAE) between non-invasive estimated central venous pressure (Doppler-coupled occlusion-pressure device) and invasive central venous pressure (central venous catheter)
Prazo: At time of single study session, up to 60 minutes
Unit of Measure: mmHg For each participant, the non-invasive estimated CVP value derived from the Doppler-coupled occlusion-pressure measurement (5 technical replicates per session) will be compared to the simultaneous invasive CVP value obtained from the central venous catheter (standard of care). The primary reportable outcome is the MAE across participants, defined as the mean of the absolute difference between paired estimated and measured CVP values, expressed in mmHg. The pre-specified target is MAE ≤ 2 mmHg, consistent with the sample-size justification (n=25 to achieve 80% power assuming an acceptable margin of error of 2 mmHg, a Type I error rate of 5%, and an expected standard deviation of 4 mmHg from prior literature). Intermediate algorithm inputs including vein-occlusion pressure, initial vein diameter, Doppler-isolated venous waveform characteristics, internal jugular vein Doppler recording, and intrapatient and interpatient variability of device output.
At time of single study session, up to 60 minutes

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Correlation between non-invasive estimated central venous pressure and invasive central venous pressure, adjusted for concurrent physiologic context variables abstracted from the electronic medical record
Prazo: At time of single study session, up to 60 minutes
Unit of Measure: Pearson correlation coefficient (r), unitless, range -1.00 to +1.00 Strength of the linear association between the non-invasive estimated CVP (Doppler-coupled occlusion-pressure device) and simultaneous invasive CVP (central venous catheter). The regression model will adjust for concurrent physiologic context variables abstracted from the EMR at the single study session - collected as standard of care, with no extra research procedures: heart rate, cardiac rhythm, respiratory rate, non-invasive and arterial-line blood pressure (systolic, diastolic, MAP), SpO2, ETCO2, awRR, mixed venous oxygen saturation, stroke volume, cardiac output, and intracardiac chamber pressures. Only readily available EMR parameters will be recorded; no procedures will be added to obtain missing data.
At time of single study session, up to 60 minutes

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de julho de 2026

Conclusão Primária (Estimado)

1 de julho de 2027

Conclusão do estudo (Estimado)

1 de dezembro de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

1 de maio de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

6 de maio de 2026

Primeira postagem (Real)

13 de maio de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

13 de maio de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

6 de maio de 2026

Última verificação

1 de maio de 2026

Mais Informações

Termos relacionados a este estudo

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .