Overcoming the Barriers to Effective Transcranial Temporal Interference Stimulation in Humans

14 de maio de 2026 atualizado por: Mathew Yarossi, Northeastern University
Transcranial temporal interference stimulation (TIS) is an emerging novel tool for non-invasive transcranial brain stimulation that holds the potential for focal and steerable neuromodulation, and the possibility to stimulate focally at depth. TIS involves combining two high frequency waveforms to create a waveform with a "beat" frequency that is physiological relevant for neuromodulation. Successful applications to deep brain targets as well as steerability of the stimulation focus have been demonstrated in mice. Numerous recent investigations in humans have shown great clinical potential for this technology, however several questions about the basic mechanism of TIS action remain. The investigators will apply TIS to the motor cortex of humans and use established transcranial magnetic stimulation techniques to assess cortical excitability in relation to the phase of the TIS waveform. Using TMS, the investigators will i) validate that effects of TIS are due to the "beat" frequency and not the high frequency carrier signal, ii) evaluate the effect of the TIS carrier frequency, and iii) evaluate that whether changes in corticospinal excitability outlast the period of stimulation. Knowledge gained from this experiment will provide a basis for the future use of TIS for clinical applications, including informing parameter optimization.

Visão geral do estudo

Descrição detalhada

Remedies for treatment resistance in psychiatric and neurological disorders is a great unmet need. Invasive neuromodulation, such as deep brain stimulation (DBS), applied to a targeted brain region is one option that has helped regulate or modify, abnormal electrical patterns in many patients with neurological deficits; However, invasive approaches carry significant risks while having limited targeting flexibility. Transcranial temporal interference stimulation (TIS) is a non-invasive neuromodulation method with much more favorable focus in deep brain targets than traditional forms of transcranial alternating current stimulation (tACS). tTIS achieves its focal effect by delivering two sinusoidal currents, that are both high in frequency, but that are slightly different from one another (e.g. 1000 kHz and 1020 kHz) through electrodes placed on the scalp. Frequencies that are in the kilohertz range alone do not elicit neuronal response, however the interaction of the two high-frequency currents creates an electric field with a high-frequency carrier (fc, e.g. 1010 kHZ) that is modulated by a low-frequency beat (fb, e.g. 20 Hz). If fc is high enough (>1 kHz) and fb low enough (<100 Hz), neurons respond much more strongly to fb than fc.

Safety and tolerability of TIS has recently been demonstrated in humans with findings indicating that TIS poses no greater risk than other common non-invasive techniques for transcranial current stimulation (TCS). The spatial distribution of the beat field (Eb) is distinct from other noninvasive stimulation methods in three ways: 1) it is focal, 2) it can peak deep in the brain, 3) it can be steered through the brain without moving the electrodes. These features have been demonstrated in mouse experiments, and in human simulation studies.

In humans, motor-evoked potentials (MEPs) elicited by transcranial magnetic stimulation (TMS) applied to the motor cortex provide an established assay of corticospinal excitability. TMS experiments have provided direct evidence that phase-dependent neuromodulation can be induced by transcranial alternating current stimulation (tACS), a form of transcranial current stimulation that is similar to temporal interference stimulation (TIS) but lacks focality and steerability, yet has been key to understanding its neurophysiological effects in humans. For example, recent experimental results showed that TMS pulses time locked to tACS over motor cortex induced MEP amplitude modulation that was dependent on the phase of the tACS oscillatory currents. Building on this finding, the investigators will provide TMS pulses to motor cortex during tTIS and investigate whether neuromodulation of corticospinal excitability depends on the phase of beat frequency (fb). Similar to the experiments that showed neural activation in mice, the investigators will also investigate whether the strength of the effect depends on the carrier frequency (fc). The investigators will use computationally optimized electrode placement, with high- and low-frequency controls, to test that effects are unambiguously due to fb. Finally, the investigators will assess corticospinal excitability PRE and POST stimulation to investigate neuroplasticity induced by TIS. The knowledge gained in this experiment will demonstrate the extent to which modulation effects of TIS in humans are due entrainment of neural activity at fb. This information will provide a basis for the future use of tTIS for clinical applications.

Tipo de estudo

Intervencional

Inscrição (Estimado)

30

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Locais de estudo

    • Massachusetts
      • Boston, Massachusetts, Estados Unidos, 02115-5724
        • Recrutamento
        • Northeastern University
        • Contato:
        • Investigador principal:
          • Mathew Yarossi, PhD

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto
  • Adulto mais velho

Aceita Voluntários Saudáveis

Sim

Descrição

Inclusion Criteria:

  • Free of neurological or orthopedic conditions that may impact the ability to participate.
  • Right-hand dominant (self-reported)
  • Aged 18-65 years

Exclusion Criteria:

  • Ferromagnetic metal implants in the brain/skull or elsewhere (dental implants excluded).
  • Any implanted electronic device (e.g. cardiac pacemaker, cochlear implant, deep brain stimulator, medication infusion pump; vagal nerve stimulator)
  • Diseased or damaged skin on face or scalp
  • History of migraines, fainting, seizures/epilepsy, or psychiatric illness
  • Neurological disorder or intracranial lesion
  • Frequent or severe headaches
  • Prior adverse reaction to transcranial magnetic stimulation
  • Currently pregnant
  • Suspected or diagnosed heart problems (e.g. arrhythmia, cardiac disturbances).
  • Insulin-dependent diabetes
  • Suspected or diagnosed epilepsy or a familial history of epilepsy
  • Use of alcohol or recreational drugs in the prior 12 hours
  • Use of prescription and over the counter medications will be grounds for exclusion except for: contraceptive (birth control) drugs (e.g. those containing ethinyl estradiol and/or norethindrone), and seasonal allergy medications (e.g. cetirizine (Zyrtec), fexofenadine (Allegra), and loratadine (Claritin)).

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Ciência básica
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição cruzada
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: 990-1010 Hz fb
We will apply temporal interference stimulation (tTIS) for 20 minutes over the motor cortex concurrent with single-pulse transcranial magnetic stimulation (TMS) (also over the motor cortex). Motor evoked potentials will be recorded using electromyography (EMG).
Experimental: 1990-2010 Hz fb
We will apply temporal interference stimulation (tTIS) for 20 minutes over the motor cortex concurrent with single-pulse transcranial magnetic stimulation (TMS) (also over the motor cortex). Motor evoked potentials will be recorded using electromyography (EMG).
Experimental: 1000-1000 Hz fb
We will apply temporal interference stimulation (tTIS) for 20 minutes over the motor cortex concurrent with single-pulse transcranial magnetic stimulation (TMS) (also over the motor cortex). Motor evoked potentials will be recorded using electromyography (EMG).
Experimental: 2000-2000 Hz fb
We will apply temporal interference stimulation (tTIS) for 20 minutes over the motor cortex concurrent with single-pulse transcranial magnetic stimulation (TMS) (also over the motor cortex). Motor evoked potentials will be recorded using electromyography (EMG).
Experimental: 20 Hz
We will apply temporal interference stimulation (tTIS) for 20 minutes over the motor cortex concurrent with single-pulse transcranial magnetic stimulation (TMS) (also over the motor cortex). Motor evoked potentials will be recorded using electromyography (EMG).
Comparador Falso: sham
We will apply temporal interference stimulation (tTIS) for 20 minutes over the motor cortex concurrent with single-pulse transcranial magnetic stimulation (TMS) (also over the motor cortex). Motor evoked potentials will be recorded using electromyography (EMG).

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Online phase-dependent modulation of corticospinal excitability using the relevance value (R.V.)
Prazo: Periprocedural
Explained variance (R2) of best-fit sinusoids will be multiplied by the variance of measured values to obtain the established "relevance value" (R.V.), to be used as our primary outcome. Relevance values assume phase-dependent modulation with a large amplitude is more meaningful than one with small amplitude and the same R2. Critically, phase-dependent responses to TIS represent direct evidence of modulation at beat frequency (fb).
Periprocedural

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Offline neuroplastic effects from pre to post
Prazo: Periprocedural
We define neuro- plastic effects as sustained modulation of excitability fol- lowing cessation of transcranial current sitmulation (tCS). Fifteen single-pulse MEPs will be acquired at the FDI hotspot prior to and at 0, 15 and 30 minutes after tCS (tpre, t0, t15, t30). Our primary outcome will be MEP amplitude change from tpre to t0.
Periprocedural
Offline neuroplastic post effects
Prazo: Periprocedural
Retention of neuromodulation at t15 and t30.
Periprocedural

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Mathew Yarossi, PhD, Northeastern University

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de fevereiro de 2026

Conclusão Primária (Estimado)

1 de outubro de 2029

Conclusão do estudo (Estimado)

1 de outubro de 2029

Datas de inscrição no estudo

Enviado pela primeira vez

5 de maio de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

14 de maio de 2026

Primeira postagem (Real)

18 de maio de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

18 de maio de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

14 de maio de 2026

Última verificação

1 de maio de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 25-02-54
  • 5R01NS133229 (Concessão/Contrato do NIH dos EUA)

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

INDECISO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Sim

produto fabricado e exportado dos EUA

Sim

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever